Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-09-23 Cont ID  
Sent By jwitmer Date 2011-09-23 Time 15:47 Rev Time 0.44
Received By jwitmer Date 2011-09-23 Time 15:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-09-16 Cont ID  
Sent By jwitmer Date 2011-09-16 Time 14:01 Rev Time 0.55
Received By jwitmer Date 2011-09-16 Time 14:01 Sent To  
Notes
2011-09-16 14:12:40BUILDING PLAN REVIEW
 PERMIT: 11080733
 ADD: 7430 BLUE HERON WAY
 CONT: FLORIDA SCREEN BUILDERS
 TEL: (561)502-7328
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PAGE 1 OF 19 ALLOWABLE POST HEIGHT (SPAN) FT FOR 2
 EACH 3/8 INCH CONCRETE FASTENERS:
 IT APPEARS THE SPANS WERE/ ARE LARGER THAN 5.5 FEET AS
 HIGHLIGHTED ON PLANS SPANS OF 5'-11 1/4" ARE EVIDENT.
  
 2) PAGE 1 OF 62 ALLOWABLE SPANS FOR MANSARD BEAMS WITH
 A RISE OF 4 FT (MAXIMUM).
 HIGHLIGHTED BEAM IS 2X9 AT A 5'-6" SPACING SPANNING
 33'-9". WHERE AS THE LAY OUT SHEET INDICATES 2X10 AT A
 SPACING OF 5'-11 1/4" SPANNING 42'-10" . IF THE 2/10'S
 WERE HIGHLIGHTED AT A 6'-0" SPACING THEY CAN ONLY SPAN
 38'-8" .
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-09-23 Cont ID  
Sent By jwitmer Date 2011-09-23 Time 15:48 Rev Time 0.00
Received By jwitmer Date 2011-09-15 Time 11:04 Sent To  
Notes
2011-09-15 11:05:34INCOMING SENT TO ZONING BOX. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-09-23 Cont ID  
Sent By jwitmer Date 2011-09-12 Time 15:48 Rev Time 0.00
Received By jwitmer Date 2011-08-30 Time 10:32 Sent To  
Notes
2011-08-30 10:32:50INCOMING SENT TO ZONING BOX.JW

Review Stop Z ZONING
Rev No 2 Status P Date 2011-09-23 Cont ID  
Sent By ajones Date 2011-09-23 Time 15:23 Rev Time 0.00
Received By ajones Date 2011-09-19 Time 14:13 Sent To  
Notes
2011-09-19 14:13:45GIVEN TO LINDA FRANCO

Review Stop Z ZONING
Rev No 1 Status F Date 2011-09-12 Cont ID  
Sent By lfranco Date 2011-09-12 Time 19:40 Rev Time 0.50
Received By lfranco Date 2011-08-30 Time 11:53 Sent To  
Notes
2011-09-12 19:47:21PLANNING AND ZONING: **** FAILED ****
  
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. PURSUANT TO THE IBIS RESIDENTIAL PLANNED DEVELOPMENT
 ("RPD") DEVELOPMENT REGULATIONS, THE SETBACK FOR A
 SCREEN ENCLOSURE IS THREE (3) FEET FROM THE ALL
 PROPERTY LINES. THE PLANS SHOW TWO (2) FEET ON THE REAR
 CORNER SIDE. REVISE ACCORDINGLY.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO, AICP
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  
  
  
  