| 2011-08-30 18:11:27 | RESIDENTIAL (R3) ACCORDION SHUTTERS, BUILDING REVIEW |
| | CHECKLIST. |
| | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| | |
| | 1- CLEARLY IDENTIFY ON ACCORDION SHUTTERS DRAWINGS |
| | WHICH SPECIFIC WALL ASSEMBLY (SEE PAGE 9 OF 18) IS |
| | GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE |
| | OPENING DESIGN PRESSURES, SELECTED ANCHOR TYPE AND |
| | SPACING, MAXIMUM SHUTTER SPAN, TYPE OF BLADE |
| | LIMITATIONS ETC. SEC 106.1.1 CITY AMENDMENTS TO FBC AND |
| | CITY POLICY FOR SHUTTERS INSTALLATION. |
| | |
| | 2- INSTALLATION SCHEDULE SUBMITTED INDICATES USING ALL |
| | POINTS SOLID-SET ANCHORS. TABLES ON SHEET 6 OF 18 AND |
| | SHEET 7 OF 18 DON'T ALLOW THE USE OF THIS CONNECTOR ON |
| | SOME APPLICATIONS. CLEARLY MARK ON THESE SHEETS WHICH |
| | ARE THE APPLICATIONS THAT APPLY USING THE ALL POINTS |
| | SOLID-SET ANCHOR TO VERIFY COMPLIANCE WITH THE DESIGN |
| | PRESSURES, SHUTTERS SPACING AND ANCHOR SPACING. SEC. |
| | 106.1.1 CITY AMENDMENTS TO FBC. |
| | |
| | 3- DESIGN PRESSURES CALCULATIONS DONE BY RAMMS |
| | ENGINEERING, INC. NEED TO HAVE ENGINEER'S ORIGINAL SEAL |
| | AND SIGNATURE AS REQUIRED BY CHAPTER 471 FLORIDA |
| | STATUTES. |
| | |
| | 4- FLOOR PLAN SUBMITTED SHOWS 19 OPENINGS, WHILE |
| | SHUTTERS INSTALLATION SCHEDULE SHOWS 18 OPENINGS. |
| | REVISE/CLARIFY AS REQUIRED. |
| | |