| Plan Review Stops For Permit 11080715 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-09-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-09 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-09-09 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-09-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-09 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-09-09 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2011-09-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-09 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-09-09 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2011-09-09 10:53:03 | SEPARATE PERMIT, APPLICATION AND PLAN REVIEW IS | | | REQUIRED FOR GAS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-10-07 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-10-05 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2011-10-05 16:52:08 | SENT TO R MC DOUGALS DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-09-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-30 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-09-15 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2011-09-15 10:44:17 | INCOMING SENT TO ZONING BOX. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-09-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-09 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-25 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2011-08-25 14:35:27 | TO ZONING | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2011-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-10-07 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-10-07 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2011-09-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-30 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-09-30 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2011-09-30 11:57:25 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY PLUMBING | | | | | | 1) THE MAXIMUM FLOW RATES FOR THE VARIABLE SPEED PUMPS | | | WAS NOT USED IN THE TDH CALCULATIONS AS STATED IN THE | | | FIRST REVIEW COMMENT #1. | | | | | | 2) THE MAXIMUM WATER VELOCITY OF 6 FEET PER SECOND IN | | | THE 2.5" BRANCH SUCTION PIPING AND THE 8 FEET PER | | | SECOND IN THE 2.5" MAIN SUCTION PIPING IS EXCEEDED WHEN | | | USING THE MAXIMUM FLOW RATE OF 145 GPM FOR THE VARIABLE | | | SPEED PUMPS THAT WERE SPECIFIED. ANSI/APSP-7 SECTION | | | 4.4 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-09-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-09 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-09-09 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2011-09-09 11:55:56 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY PLUMBING | | | FBC R4101 & ANSI/APSP 7 | | | | | | 1) THE PLANS SPECIFY TWO VARIABLE SPEED PUMPS WHICH | | | REQUIRE THE MAXIMUM FLOW RATE OF THE PUMP TO BE USED IN | | | CALCULATIONS. SEE NOTE NUMBER 1 ON TDH CALCULATION WORK | | | SHEET. | | | | | | 2) SPECIFY THE MANUFACTURER, MODEL NUMBER AND HORSE | | | POWER OF EACH PUMP. SUBMIT 2 COPIES OF THE | | | SPECIFICATIONS FOR EACH OF THE THREE POOL PUMPS | | | INCLUDING THE PUMP CURVES. | | | | | | 3) SUBMIT 2 COPIES OF TOTAL DYNAMIC HEAD (TDH) | | | CALCULATIONS FOR EACH OF THE SYSTEMS OR DESIGN THE | | | SYSTEMS FOR THE MAXIMUM FLOW RATE OF THE PUMP. | | | | | | 4) SUBMIT A PIPING DIAGRAM THAT SPECIFIES ALL PIPE | | | SIZES IN EACH SYSTEM. | | | | | | 5) THE FIRST SHEET OF PLANS SHOWS FIVE SETS OF MAIN | | | DRAINS FOR A TOTAL OF 10. THE PIPING DIAGRAM SHOWS FOUR | | | SETS OF MAIN DRAINS FOR A TOTAL OF 8. PLEASE CLARIFY. | | | | | | 6) THE VALUE FOR THE SCOPE OF WORK APPEARS TO BE LOW. | | | PLEASE SUBMIT A COPY OF THE SIGNED CONTRACT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2011-09-29 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2011-09-29 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2011-09-16 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2011-09-29 14:04:53 | PLANNING AND ZONING: *** POOL PERMIT PASSED: A FENCE | | | POOL BARRIER WAS SUBMITTED AND APPROVED. INSTALL FENCE | | | AROUND PROPERTY LINE & FENCE TO SERVE AS POOL BARRIER - | | | PERMIT NUMBER 11090169 ***** | | | | | | | | | | | | | | | 9/26/11 JORGE P/U PERMIT A | | | 9/26/11 CALLED CONTRACTOR PERMIT READY FOR ISSUE W/ FEE | | | 137.50 FILE UNDER "J" SMALL BIN AR | | | 9/23/11- APPROVED ROUTED TO MISC #2- AV | | 2011-09-16 13:03:50 | GIVEN TO LINDA FRANCO |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-09-01 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2011-09-01 |
Time |
18:11 |
Rev Time |
0.50 |
| Received By |
lfranco |
Date |
2011-08-29 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2011-09-01 18:59:41 | PLANNING AND ZONING: **** FAILED **** | | | | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | | | 2. AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT | | | FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT | | | SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO | | | THE MINIMUM STANDARDS PROVIDED BELOW: PLEASE REFERENCE | | | THE POOL PERMIT IN THE FENCE PERMIT FOR EASIER | | | PROCESSING OF BOTH PERMITS. | | | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B) AND | | | (C): | | | B. EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR | | | SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS | | | BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE | | | RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | C. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH | | | A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING | | | GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES | | | PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. AT | | | LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN | | | ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH | | | AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL | | | BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO, AICP | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] | | | | | | |
|
|