Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-09-29 Cont ID  
Sent By jgomez Date 2011-09-29 Time 10:33 Rev Time 0.00
Received By jgomez Date 2011-09-29 Time 10:33 Sent To  
Notes
2011-09-29 10:34:47BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- COMPLY WITH ANCHOR SPACING AS REDLINED ON THE
 INSTALLATION SCHEDULE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-08-30 Cont ID  
Sent By jgomez Date 2011-08-30 Time 17:09 Rev Time 0.00
Received By jgomez Date 2011-08-30 Time 17:09 Sent To  
Notes
2011-08-30 17:56:09RESIDENTIAL (R3) ACCORDION SHUTTERS, BUILDING REVIEW
 CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- CLEARLY IDENTIFY ON ACCORDION SHUTTERS DRAWINGS
 WHICH SPECIFIC WALL ASSEMBLY (SEE PAGE 9 OF 18) IS
 GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 OPENING DESIGN PRESSURES, SELECTED ANCHOR TYPE AND
 SPACING, MAXIMUM SHUTTER SPAN, TYPE OF BLADE
 LIMITATIONS ETC. SEC 106.1.1 CITY AMENDMENTS TO FBC AND
 CITY POLICY FOR SHUTTERS INSTALLATION.
  
 2- THERE ARE TWO DIFFERENT PRODUCT APPROVALS SUBMITTED
 FL11349-R2 AND FL11354-R2. CLEARLY MARK ON EACH PRODUCT
 APPROVAL SPECIFIC MOUNTING CONDITIONS AND ANCHOR TYPE
 AND SPACING TO BE USED. SEE ITEM #1 ABOVE. SEC. 106.1.1
 CITY AMENDMENTS TO FBC.
  
 3- INSTALLATION SCHEDULE SUBMITTED INDICATES USING ALL
 POINTS SOLID-SET ANCHORS. TABLES ON SHEET 6 OF 18 AND
 SHEET 7 OF 18 DON'T ALLOW THE USE OF THIS CONNECTOR ON
 SOME APPLICATIONS. CLEARLY MARK ON THESE SHEETS WHICH
 ARE THE APPLICATIONS THAT APPLY USING THE ALL POINTS
 SOLID-SET ANCHOR TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES, SHUTTERS SPACING AND ANCHOR SPACING. SEC.
 106.1.1 CITY AMENDMENTS TO FBC.
  
 4- DESIGN PRESSURES CALCULATIONS DONE BY RAMMS
 ENGINEERING, INC. NEED TO HAVE ENGINEER'S ORIGINAL SEAL
 AND SIGNATURE AS REQUIRED BY CHAPTER 471 FLORIDA
 STATUTES.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-09-29 Cont ID  
Sent By jgomez Date 2011-09-29 Time 10:35 Rev Time 0.00
Received By jgomez Date 2011-09-15 Time 10:55 Sent To  
Notes
2011-09-15 10:56:21INCOMING SENT TO J. GOMEZ DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-08-30 Cont ID  
Sent By jgomez Date 2011-08-30 Time 17:08 Rev Time 0.00
Received By jgomez Date 2011-08-30 Time 10:25 Sent To  
Notes
2011-08-30 10:25:54INCOMING SENT TO MISC BOX# 1 . JW


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved