| Plan Review Stops For Permit 11080680 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-11-08 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-11-08 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2011-11-08 15:00:33 | BUILDING PROVISO | | | | | | SUBMIT SIGNED AND SEALED RAS 117 CALCULATIONS FOR THE | | | ROOFING MATERIAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-11-08 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-11-08 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2011-11-08 11:44:06 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE RAS 117 CALCULATIONS FOR THE ENHANCED ROOFING | | | FASTENING IS REQUIRED TO BE SIGNED AND SEALED BY THE | | | ENGINEER. FS 471 | | | | | | 2) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE | | | SIGNED BY THE OWNER/AGENT. FBC N1100.2.2 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-22 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-09-22 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2011-09-22 11:01:26 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) ON SHEET A-5 SECTION B-B APPEARS TO SHOW A FRAMED | | | WALL OR BRACE EXTENDING FROM THE CANTILEVERED BAY | | | WINDOW TO THE FOOTER. PLEASE CLARIFY AND SHOW | | | COMPLIANCE WITH FBC R319 PROTECTION AGAINST DECAY. | | | | | | 2) PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD OF THE | | | PROJECT. CITY AMENDMENTS 106.3.3 | | | | | | 3) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE | | | ROOFING MATERIALS THAT WILL BE INSTALLED. SUBMIT RAS | | | 117 CALCULATIONS FOR THE FLAT ROOF IF ENHANCED | | | FASTENING IS REQUIRED. DCA RULE 9N-3 | | | | | | 4) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE | | | STRUCTURAL WINDOW MULLIONS. DCA RULE 9N-3 | | | | | | 5) SPECIFY WHICH ONE OF THE WINDOWS LISTED IN THE | | | FLORIDA PRODUCT APPROVAL WILL BE INSTALLED. YOU CAN | | | CIRCLE THE APPROPRIATE ONE ON THE PRODUCT APPROVAL. | | | MAKE SURE THAT THE DESIGN PRESSURES AND IMPACT RATING | | | INFORMATION ARE PROVIDED. | | | | | | 6) SPECIFY WHICH ONE OF THE DOORS LISTED IN THE FLORIDA | | | PRODUCT APPROVAL WILL BE INSTALLED. YOU CAN CIRCLE THE | | | APPROPRIATE ONE ON THE PRODUCT APPROVAL. MAKE SURE THAT | | | THE DESIGN PRESSURES AND IMPACT RATING INFORMATION ARE | | | PROVIDED. | | | | | | 8) IF THE WINDOWS OR DOORS WITH GLAZING ARE NOT IMPACT | | | RATED, SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | STORM PANELS THAT WILL BE USED AS REQUIRED BY DCA RULE | | | 9N-3. TWO COPIES OF A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR OPENING PROTECTIVE DEVICES WILL ALSO BE | | | REQUIRED. AN INSTALLATION SCHEDULE IS AVAILABLE AT HTTP | | | ://WWW.WPB.ORG/CONSTRUCTION/PERMITS_PERMIT_INFORMATION. | | | PHP. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2011-11-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-11-08 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-11-08 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2011-11-03 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-11-03 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-11-03 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2011-11-03 11:42:28 | 11080680 | | | 509 27TH ST. | | | INTERIOR RENOVATION | | | | | | THE ELECTRICAL PLAN NEEDS TO BE SIGNED BY THE DESIGN | | | PROFESSIONAL . THE PLAN SHOULD DELINEATE THE SCOPE OF | | | WORK BETWEEN NEW AND EXISTING. SHOW AC AND HEATING. | | | CLEARLY SHOW THE INTERCONNECTED SMOKE ALARMS AND CARBON | | | MONOXIDE ALARMS AS REQUIRED BOTH WITHIN AND OUTSIDE THE | | | SLEEPING AREAS. FBC R313 | | | ALL NEW BRANCH CIRCUITS MUST BE PROTECTED WITH ARC | | | FAULT CIRCUIT INTERRUPTERS. NEC 210.12 | | | KITCHEN COUNTER TOP AND BATHROOM RECEPTACLES MUST BE | | | GFCI PROTECTED. NEC 210.8 | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT NEC 406.11 | | | BATHROOMS REQUIRE DEDICATED 20 AMP BRANCH CIRCUITS. NEC | | | 210-11(C)(3) | | | A BONDING STRIP IS REQUIRED AT SERVICE GROUND NEC | | | 250.94 | | | GFCI PROTECTED RECEPTACLES ARE REQUIRED AT FRONT AND | | | REAR ELEVATIONS. NEC 210.8 | | | AN ELECTRICAL RISER WITH PANEL SCHEDULE AND LOAD | | | CALCULATION IS REQUIRED IF THE HOME IS BEING REWIRED. | | | SHOW SERVICE AND PANEL BOARD LOCATIONS. NEC 215.15 | | | IF THE SCOPE OF RECONSTRUCTION INCLUDES AN ELECTRICAL | | | CONNECTION TO THE GARAGE FROM THE HOUSE THAN A SPECIFIC | | | WIRING METHOD IS REQUIRED. NEC 250.32 | | | | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-09-14 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-09-14 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-09-14 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2011-09-14 12:07:03 | 11080680 | | | 509 27TH ST. | | | | | | PLEASE PROVIDE AN ELECTRICAL PLAN SHOWING COMPLIANCE | | | WITH THE REQUIREMENTS OF THE CODE FOR RECEPTACLES, | | | LIGHTING, GFCIS, AFCIS, SMOKE ALARMS, CARBON MONOXIDE | | | DETECTORS, LOCATION OF THE ELECTRICAL PANEL AND | | | SERVICE, ETC. NEC 215.5 | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-11-01 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-11-01 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-11-01 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-08-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2011-08-30 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2011-08-30 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-11-08 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-10-28 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-22 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-25 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2011-08-25 08:44:00 | SENT TO R1 SHELF FOR REVIEW BY ALL TRADES. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2011-11-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-11-08 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-11-08 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2011-11-08 14:46:31 | 2011-18703 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2011-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-22 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-09-22 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2011-09-22 09:07:36 | IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2011-11-01 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-11-01 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-11-01 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2011-11-01 11:06:26 | PROVISO: | | | | | | PER SECTION 94-442, FOR SINGLE-FAMILY DWELLING UNITS, | | | AT LEAST ONE SHADE, FLOWERING OR FRUIT TREE SHALL BE | | | PLANTED FOR EACH 1,200 SQUARE FEET OF OPEN SPACE OR | | | PORTION THEREOF. FOR SINGLE-FAMILY DWELLING UNITS, AT | | | LEAST ONE SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE | | | FEET OF OPEN SPACE OR PORTION THEREOF. PALM TREES MAY | | | BE SUBSTITUTED FOR NOT MORE THAN 35 PERCENT OF THE | | | SHADE OR FLOWERING TREES REQUIRED BY THIS ARTICLE, | | | EXCEPT AS SPECIFIED IN THE COMPREHENSIVE PLAN. HOWEVER, | | | WHEN PALM TREES ARE SUBSTITUTED FOR SHADE TREES, TWO | | | PALM TREES SHALL BE PROVIDED FOR EACH REQUIRED SHADE | | | TREE. THIS 2:1 SUBSTITUTION SHALL NOT BE REQUIRED FOR | | | ROYAL PALM TREES AND SUCKERING PALM TREES SUCH AS THE | | | ARECA PALM, PAUROTIS PALM AND THE SENEGAL DATE PALM. | | | | | | ACCORDING TO THE INFORMATION SUBMITTEDM THE TOTAL OPEN | | | SPACE IS 5,374 SQUARE FEET. THEREFORE, AT LEAST 5 | | | SHADE, FRUIT OR FLOWING TREES AND 11 SHRUBS ARE | | | REQUIRED. | | | | | | THE PROPOSED LANDSCADE PLAN DOES NOT MEET THE CURRENT | | | MINIMUM STANDARDS; AT LEAST TWO ADDITIONAL SHADE, FUIT | | | OR FLOWERING TREES SHALL BE INSTALLED PRIOR TO ISSUANCE | | | OF THE CERTIFICATE OF OCCUPANCY. | | | | | | FOR MORE INFORMATION, PLEASE CONTACT JILLIAN PAPA, | | | HISTORIC PRESERVATION PLANNER AT 561-822-1454. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2011-08-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2011-08-30 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2011-08-30 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2011-08-30 15:35:40 | THE VALUE OF THE CONSTRUCTION ($147,000) EXCEEDS 50% OF | | | THE STRUCTURE'S VALUE ($66,071) ACCORDING TO THE P.B.C. | | | PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT TO | | | SECTION 94-441(C)(2) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | | SITE INTO CONFORMITY. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2011-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-22 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-09-22 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2011-09-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-09-21 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-09-21 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2011-11-01 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-11-01 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-11-01 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-08-30 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2011-08-30 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2011-08-30 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2011-08-30 15:30:49 | REQUIRES LANDSCAPING PLAN, SEE NOTES UNDER LANSCAPE | | | STOP. |
|
|