Plan Review Details - Permit 11080357
Plan Review Stops For Permit 11080357
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-09-14 Cont ID  
Sent By aaponte Date 2011-09-22 Time 11:39 Rev Time 0.50
Received By lmartine Date 2011-09-14 Time 11:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-08-19 Cont ID  
Sent By shill Date 2011-08-19 Time 16:34 Rev Time 0.00
Received By shill Date 2011-08-19 Time 14:15 Sent To  
Notes
2011-08-19 15:49:22****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. G1, CODE COMPLIANCE, STATES EXISTING OCCUPANCY AS B.
 OUR RECORDS SHOW THIS AS A2, SEE FBC 302. A CHANGE OF
 OCCUPANCY IS TO COMPLY WITH ONE OF THE METHODS IN THE
 EXISTING BUIDLING CODE. PLEASE NOTE CHANGE OF OCCUPANCY
 ON THE PLAN AND CONFIRM COMPLIANCE WITH ALL
 REQUIREMENTS.
  
 2. ACCESSIBLE PARKING TO BE LOCATED ON AN ACCESSIBLE
 ROUTE NO LESS THAN 44", PLEASE SHOW DIMENSION OF ACCESS
 AISLE AND ACCESSIBLE ROUTE FBC11-4.6.
  
 3. IT APPEARS THAT DETECTABLE WARNINGS MAY BE REQUIRED
 FROM THE ACCESSIBLE PARKING TO THE BUILDING AS IT
 CROSSES THE DRIVE THRU AREA, FBC11-4.25.9.
  
 4. FLORIDA STATE OR LOCAL PRODUCT APPROVAL OR MIAMIDADE
 NOA REQUIRED FOR ALL COMPONENTS & CLADDING. THE ROOF
 PRODUCT APPROVAL MAY BE SUBMITTED WITH THE ROOF PERMIT
 (SEE 11080356). PROVIDE PRODUCT APPROVAL FOR THE
 FOLLOWING:
 EXTERIOR DOORS
 STOREFRONT
 HARDIPLANK SIDING
  
 PRODUCT APPROVALS TO BE REVIEWED BY DESIGNER OF RECORD
 PRIOR TO SUBMITTAL, FBC106.3.3.
  
 5. A1, 321 B NOTES A MAX 1/2" ELEVATION CHANGE. PLEASE
 SEE DOOR PRODUCT APPROVAL AND THRESHOLD AND PROVIDE
 MORE INFORMATION REGARDING HOW THE ELEVATION CHANGE
 PLUS DOOR THRESHOLD, IF ANY, WILL COMPLY WITH FBC
 11-4.3.8 (DOORS 1 & 8).
  
 6. ADVISORY ONLY, SEPARATE PERMIT, PLANS AND REVIEWS
 WILL BE REQUIRED FOR THE CANOPY. ALTERNATIVELY, SUBMIT
 ALL STRUCTURAL AND SITE PLAN INFORMATION TO HAVE IT
 INCLUDED IN THE SCOPE OF WORK FOR THIS PERMIT.
  
 7. THE WATER FOUNTAINS APPEAR TO OBSTRUCT THE
 MANEUVERING CLEARANCE REQUIRED FOR DOORS 5 & 6, PULL
 SIDE. PLEASE NOTE THAT A SINGLE FOUNTAIN WITH A CUP
 HOLDER WOULD BE ACCEPTABLE IF DESIGNER CHOOSES TO ELECT
 THIS OPTION (FOUNTAIN AT WHEELCHAIR HEIGHT) PER
 BUILDING OFFICIAL.
  
 8. A9 SHOWS STUCCO TERMINATING BELOW GRADE. SEE
 FBC1407.3 AND REVISE DETAIL TO SHOW COMPLIANCE.
  
 9. ADDITION AND CANOPY ARE NOT SHOWN ON THE SITE PLAN.
 PLEASE REVISE.
  
 10. CURB RAMP NOT TO BE LESS THAN 44", FBC 11-4.7.3,
 PLEASE ADD DIMENSION TO A0.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-08-17 Cont ID  
Sent By rlecky Date 2011-08-17 Time 12:22 Rev Time 0.00
Received By rlecky Date 2011-08-17 Time 12:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-08-16 Cont ID  
Sent By wjolin Date 2011-08-16 Time 14:02 Rev Time 0.00
Received By wjolin Date 2011-08-16 Time 13:42 Sent To  
Notes
2011-08-16 14:02:54600 NORTH DIXIE HIGHWAY
 PERMIT #11080357
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVIDE BUILDING ADDRESS VISIBLE FROM THE STREET.
 NUMBERS SHALL BE ATTACHED TO THE BUILDING AND BE AT
 LEAST SIX-INCHES IN HEIGHT WITH 1-INCH STROKE AND SHALL
 CONTRAST THE BACKGROUND (REFERENCE: SECTION 10.12.1.2
 OF THE FLORIDA FIRE PREVENTION CODE - NFPA 1).
  
 STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS
 CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO
 THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE LETTER R DESIGNATION PER
 FLORIDA STATUTE 633.027 AND FLORIDA ADMINISTRATIVE CODE
 69A-60.0081. NOTES: PER DISCUSSION WITH ARCHITECT
 (STACEY) ON 8/18/11; MALTESE CROSS WILL BE PLACED NEAR
 REAR ENTRANCE AS THIS DOOR IS CLOSEST TO THE FIRE
 DEPARTMENT ACCESS DRIVEWAY.
  
 PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-09-21 Cont ID  
Sent By lmartine Date 2011-09-15 Time 13:10 Rev Time 0.00
Received By lmartine Date 2011-09-14 Time 10:41 Sent To  
Notes
2011-09-21 13:12:22NEEDS CONTRACTOR
2011-09-15 09:13:01TO LM. SEPARATE LANDSCAPE NEEDED.
2011-09-14 10:56:18****************EXPEDITED*****************
 2ND RUN
2011-09-14 10:42:14IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-08-23 Cont ID  
Sent By lmartine Date 2011-08-23 Time 16:52 Rev Time 0.00
Received By lmartine Date 2011-08-15 Time 10:12 Sent To  
Notes
2011-08-15 10:13:05****************EXPEDITED*****************
 C--13

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2011-08-19 Cont ID  
Sent By shill Date 2011-08-19 Time 14:15 Rev Time 0.00
Received By shill Date 2011-08-19 Time 14:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-08-23 Cont ID  
Sent By shill Date 2011-08-23 Time 10:55 Rev Time 0.00
Received By hmoser Date 2011-08-19 Time 16:34 Sent To  
Notes
2011-08-23 10:56:05PER HM

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-08-19 Cont ID  
Sent By lwagner Date 2011-08-19 Time 13:52 Rev Time 0.00
Received By lwagner Date 2011-08-18 Time 14:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2011-09-15 Cont ID  
Sent By aaponte Date 2011-09-15 Time 08:16 Rev Time 0.00
Received By aaponte Date 2011-09-15 Time 08:16 Sent To  
Notes
2011-09-15 08:55:38PROVISO FOR LANDSCAPE FUTURE PERMIT:
 1. THE DEAD TREES TO BE REMOVED SHALL BE REPLACED. ONE
 NEW GUMBO LIMBO ALONG THE EAST PROPERTY LINE. ONE NEW
 TREE ALONG THE NORTH PROPERTY LINE, NEXT TO THE
 HANDICAP SPACE.
 2. REMOVE CONCRETE BASE EXISTING WITHIN THE PLANTING
 AREA SOUTH OF THE DIXIE HWAY DRIVEWAY.
 3. ALL WEEDS AND NOT SPECIFIED PLANT MATERIAL SHALL BE
 REMOVED.
 4. A SEPARATE LANDSCAPE PERMIT SHALL BE REQUESTED.
 5. EXISTING IRRIGATION SYSTEM SHALL BE TESTED AND
 REPAIRED IF NECESSARY.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2011-08-23 Cont ID  
Sent By aaponte Date 2011-08-23 Time 14:45 Rev Time 0.00
Received By aaponte Date 2011-08-23 Time 14:45 Sent To  
Notes
2011-08-23 15:32:221. PLEASE INCLUDE STRIPING DETAIL ACCORDING TO ZONING
 CODE. (SEC 94-485- FIG XV-2)
 2. IF EXISTING DUMPTER IS NOT NECESSARY IT SHALL BE
 REMOVED. PLEASE CONTACT MANNY GONZALEZ AT 494-1085.
 3. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE
 WITH MINIMUM TRANSPARENCY REQUIREMENTS FOR ELEVATIONS
 ALONG QUADRILLE BLVD, DIXIE HWAY AND 5TH STREET. (SEC
 94-118-TABLE IV-16). THE TRANSPARENCY IS MEASURED AS A
 PERCENTAGE OF THE FACADE (SEE FIGURE IV-33 OF THE
 ZONING CODE).
 4. MECHANICAL EQUIPMENT SHALL BE SCREENED ACCORDING TO
 SEC 94-444(B) OF THE ZONING CODE.
 5.PROPOSED ADA ACCESSIBLE ROUTE IS ENCROACHING INTO THE
 TRAVEL LANE.
 6. A SITE INSPECTION WILL BE REQUIRED TO DETERMINE THE
 CONDITION OF THE EXISTING LANDSCAPE AND REPLACEMENT
 REQUIREMENTS.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439