| Plan Review Stops For Permit 11080246 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-08-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-08-12 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-08-12 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-08-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-08-17 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-08-17 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2011-08-17 14:14:34 | SCOPE OF WORK LIMITED TO INSTALLATION OF SMOKE | | | DETECTORS AND REPAIR OR REPLACEMENT OF EXISTING | | | RECEPTACLES AND FIXTURES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-08-15 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-08-15 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-08-15 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2011-08-15 14:16:08 | | | | PLEASE PROVIDE DETAILED ELECTRICAL PLAN FOR ALL | | | IMPROVEMENTS SHOWING EXISTING AND NEW WORK. | | | | | | INDICATE THE SIZE, RATING, LOCATION OF THE EXISTING | | | SERVICE, MAIN DISCONNECT AND PANELBOARD. NEC 215.5 | | | ALL NEW GENERAL PURPOSE OUTLETS MUST BE AFCI PROTECTED. | | | NEC 210.12 | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE DETECTORS. IF THE | | | RESIDENCE HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A | | | FIRE PLACE A CARBON MONOXIDE DETECTOR IS REQUIRED | | | WITHIN TEN FEET OF EACH ROOM USED FOR SLEEPING. FBC | | | R313 | | | ADDITIONAL RECEPTACLES REQUIRED IN THE BEDROOMS AND | | | HALLWAY. ADD RECEPTACLES SO THAT NO WALL SPACE IS MORE | | | THAN 6 FEET FROM A RECEPTACLE AND ALL WALL SPACES MORE | | | THAN 2 FEET IN WIDTH HAVE A RECEPTACLE. NEC 210.52 | | | THE LIVING AREA REQUIRES A SWITCHED RECEPTACLE OR LIGHT | | | AND A SWITCH CONTROLLED OUTSIDE LIGHTS. NEC 210.70 | | | A GFCI PROTECTED RECEPTACLE IS REQUIRED OUTSIDE AT EACH | | | ENTRANCE. NEC 210.52 | | | PROVIDE TWO OR MORE 20- AMPERE SMALL APPLIANCE BRANCH | | | CIRCUITS. NEC 210.52 | | | PROVIDE A 20 AMPERE BRANCH CIRCUIT FOR THE BATHROOMS. | | | NEC 210.11 (C)(3) | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-08-22 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-08-22 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-08-22 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-09-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-09-06 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-08-26 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2011-08-26 14:58:53 | TO MECHANICAL | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-08-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-22 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-09 |
Time |
12:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2011-09-01 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-09-01 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-09-01 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2011-09-01 15:53:50 | ***PROVISO*** | | | | | | PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY, THE | | | APPLICANT MUST DEMONSTRATE COMPLIANCE WITH THE MINIMUM | | | STANDARDS FOR LANDSCAPING FOR SINGLE FAMILY DWELLINGS | | | AS DESCRIBED IN SEC. 94-442 OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, SINCE THE VALUE OF PROPOSED | | | WORK OF THE PERMIT EXCEEDS 50% OF THE ASSESSED VALUE OF | | | THE STRUCTURE (ACCORDING TO THE PROPERTY APPRAISER OF | | | PB COUNTY) . COMPLIANCE MUST BE DEMONSTRATED BY 2 | | | COPIES OF A LANDSCAPE PLAN OF THE EXISTING CONDITIONS | | | AND VERIFIED THROUGH SITE INSCPECTION. | | | | | | FOR MORE INFORMATION, PLEASE CONTACT JILLIAN PAPA, | | | HISTORIC PRESERVATION PLANNER AT 561-822-1454. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2011-08-22 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-08-22 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-08-22 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2011-08-22 15:20:07 | SEE ZONING COMMENTS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-09-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-09-06 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-09-06 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2011-09-06 09:49:30 | REFER TO SECTION M1602 2007 FBCR (M) | | | BALANCED RETURN AIR PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-08-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2011-08-12 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2011-08-12 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2011-08-12 09:57:56 | RESIDENTIAL (R3) DUCTWORK REPLACEMENT MECHANICAL REVIEW | | | CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- PROVIDE PLANS SHOWING: A) DUCTWORK SIZES, B) | | | REGISTERS SIZES AND CFM'S, AND C) THE BALANCED RETURN | | | AIR. SEC. 106.1.2 CITY AMENDMENTS TO FBC. | | | | | | 2- MECHANICAL CONTRACTOR DOING THE WORK MAY DRAW THE | | | PLANS. NEED TO SIGN THE PLANS AND PROVIDE HIS/HER NAME | | | AND LICENSE NUMBER. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-08-22 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-08-22 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
jpapa |
Date |
2011-08-22 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2011-08-22 15:11:14 | PROVISO: | | | | | | PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF THE | | | PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDRS. | | | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE ZLDRS. | | | | | | FOR MORE INFORMATION, CONTACT JILLIAN PAPA, HISTORIC | | | PRESERVATION PLANNER AT 561-822-1454. | | | |
|
|