|
 |
 |
 |
 |
 |
Plan Review Details - Permit 11080145
| Plan Review Stops For Permit 11080145 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-30 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-30 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2011-08-30 16:09:53 | ****PROVISO**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | PROVIDE A COMPLETED INSTALLATION SCHEDULE FOR THE | | | SHUTTERS AT INSPECTION. | | | | | | THIS FORM CAN BE FOUND AT: | | | | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-08-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-10 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-10 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2011-08-10 14:37:17 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PLEASE PROVIDE MORE INFORMATION REGARDING OCCUPANCY | | | CLASSIFICATION OF THIS STRUCTURE. OUR RECORDS (PRIOR TO | | | SUBMITTAL OF A RES REMOD PERMIT SHOWING RENOVATION TO | | | EXISTING DWELLING UNIT) SHOW THIS AS BUSINESS | | | OCCUPANCY. | | | | | | 2. UNLESS EVIDENCE CAN BE PROVIDED THAT THIS WAS A | | | MIXED USE STRUCTURE, SHOW COMPLIANCE WITH FBC11-4.13.8 | | | (DOOR THRESHOLD HEIGHT LIMITATION). | | | | | | 3. FAC9N-3, PROVIDE FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL FOR THE DOOR. THE EVALUATION REPORT WAS | | | SUBMITTED BUT THE COVER SHEET FROM | | | WWW.FLORIDABUILDING.ORG IS ALSO REQUIRED. | | | | | | 4. IMPACT PROTECTION REQUIRED, FBC1609.1.4. NON IMPACT | | | STOREFRONT PRODUCT APPROVALS WERE SUBMITTED. | | | | | | 5. THE FLOOR PLAN SHOWS HORIZONTAL ROLLER WINDOWS, BUT | | | BOTH HORIZONTAL ROLLER AND SINGLE HUNG WINDOW PRODUCT | | | APPROVALS WERE SUBMITTED. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-30 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-29 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2011-08-29 13:02:01 | INCOMING SENT TO S. HILL DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-08-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-10 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-04 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2011-08-04 17:52:31 | MISC 1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |