2011-09-01 12:28:532007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE ORIGINAL SIGNATURE AND SEAL OF THE ENGINEER IS
 REQUIRED ON THE ENHANCED FASTENING CALCULATIONS FOR THE
 SEALOFLEX ROOF SYSTEM. FS 471
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-08-05 Cont ID  
Sent By jgomez Date 2011-08-05 Time 15:54 Rev Time 0.00
Received By jgomez Date 2011-08-05 Time 15:54 Sent To  
Notes
2011-08-05 16:08:52NEW SINGLE FAMILY (R3) CONSTRUCTION ROOF COVERING
 BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR THE PEEL & STICK UNDERLAYMENT TYPE TO
 BE USED FOR WOOD SHAKES AND METAL ROOF APPLICATIONS AS
 SPECIFIED BY THE ARCHITECT OF RECORD ON THE
 CONSTRUCTION PLANS
  
 2- COPPER ROOF SYSTEM W-18 ON FLORIDA PRODUCT APPROVAL
 FL10601-R2 SUBMITTED DOESN'T MEET THE DESIGN PRESSURES
 FOR THE ROOF CORNER AND PERIMETER AREAS. NEED TO
 PROVIDE PRODUCT APPROVAL THAT MEETS THE DESIGN
 PRESSURES AS REQUIRED BY SEC. R301.2.1.4.3.
  
 3- BALCONY WATERPROOF SYSTEM PRODUCT APPROVAL
 SUBMITTED:
 A) CLEARLY MARK WHICH APPROVED ASSEMBLY FROM NOA
 10-0608.02 SUBMITTED IS GOING TO BE USED TO VERIFY
 COMPLIANCE WITH THE DESIGN PRESSURES OF SEC.
 R301.2.1.4.3.
  
 B) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 NAIL ENHANCING AT PERIMETER AND CORNER AS REQUIRED BY
 GENERAL LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED.
  
 4- ARCHITECT OF RECORD FOR THE NEW HOUSE TO REVIEW AND
 APPROVE IN WRITING (NOT SIGNING & SEALING) ALL PRODUCT
 APPROVALS PRIOR TO SUBMITTAL AS REQUIRED BY SEC.
 106.3.3 CITY AMENDMENTS TO FBC.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-08-05 Cont ID  
Sent By jgomez Date 2011-08-05 Time 15:54 Rev Time 0.00
Received By jgomez Date 2011-08-02 Time 14:56 Sent To  
Notes
2011-08-02 15:02:34TO JG