Plan Review Details - Permit 11080006
| Plan Review Stops For Permit 11080006 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-08-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-19 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-19 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-08-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-15 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-15 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2011-08-15 10:24:12 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. REVISE EXPOSURE CATEGORY OR PROVIDE RATIONAL | | | ANALYSIS ENGINEERING FOR USE OF EXPOSURE B PRESSURES. | | | FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE CHANGED | | | EFFECTIVE MARCH 1, 2009. | | | | | | 2ND REVIEW, NEW CALCS PROVIDED FOR EXPOSURE C BUT | | | INSTALLATION SCHEDULE STILL HAS DESIGN PRESSURE OF | | | 33.1. | | | | | | 2. TWO SETS REQUIRED. ONLY ONE INSTALLATION SCHEDULE | | | PROVIDED. IF TWO SETS ARE NOT PROVIDED, COPY FEES MAY | | | BE ADDED. | | | | | | ADDRESSED. WHEN RESUBMITTING, PLEASE AGAIN PROVIDE TWO | | | SETS. | | | | | | 3. THE INSTALLATION SCHEDULE PROVIDED WAS NOT COMPLETE. | | | PROPOSED ANCHOR SPACING AND SHUTTER GLASS SEPARATION | | | WERE LEFT BLANK. | | | | | | 2ND REVIEW, ANCHOR SPACING COLUMN IS STILL BLANK. | | | SHUTTER GLASS SEPARATION STATES "N/A"; SEE SHEET 1, | | | TABLE 4 FOR REQUIRED SHUTTER GLASS SEPARATION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-08-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-03 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-03 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2011-08-03 15:31:50 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. REVISE EXPOSURE CATEGORY OR PROVIDE RATIONAL | | | ANALYSIS ENGINEERING FOR USE OF EXPOSURE B PRESSURES. | | | FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE CHANGED | | | EFFECTIVE MARCH 1, 2009. | | | | | | 2. TWO SETS REQUIRED. ONLY ONE INSTALLATION SCHEDULE | | | PROVIDED. IF TWO SETS ARE NOT PROVIDED, COPY FEES MAY | | | BE ADDED. | | | | | | 3. THE INSTALLATION SCHEDULE PROVIDED WAS NOT COMPLETE. | | | PROPOSED ANCHOR SPACING AND SHUTTER GLASS SEPARATION | | | WERE LEFT BLANK. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-08-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-15 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-10 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2011-08-10 10:52:42 | SENT TO SAMANTHA'S DESK FOR REVIEW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-08-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-03 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-01 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2011-08-01 14:03:49 | SENT TO MISC BOX# 1. JW |
|
|
|