Plan Review Details - Permit 11070787
Plan Review Stops For Permit 11070787
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2011-08-15 Cont ID  
Sent By shill Date 2011-08-15 Time 16:12 Rev Time 0.00
Received By shill Date 2011-08-15 Time 16:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-09-23 Cont ID  
Sent By rlecky Date 2011-09-23 Time 11:29 Rev Time 0.00
Received By rlecky Date 2011-09-23 Time 11:22 Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-08-12 Cont ID  
Sent By rlecky Date 2011-08-12 Time 12:13 Rev Time 0.00
Received By rlecky Date 2011-08-12 Time 12:09 Sent To FIRE
Notes
2011-08-12 12:13:42PROVIDE ELECTRICAL CONNECTION RISER/DETAIL. PROVIDE
 SPECIFICATIONS AND LISTING FOR THE ELECTRIC GATE
 OPENER. NEC 215.15
  
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-10-13 Cont ID  
Sent By wjolin Date 2011-10-13 Time 08:33 Rev Time 0.00
Received By wjolin Date 2011-10-13 Time 08:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2011-08-12 Cont ID  
Sent By wjolin Date 2011-08-12 Time 13:42 Rev Time 0.00
Received By wjolin Date 2011-08-12 Time 13:30 Sent To B
Notes
2011-08-12 13:42:385600 NORTH FLAGLER DRIVE
 PERMIT #11070787
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PLEASE INDICATE HOW THE PROPOSED BARRIER WILL EFFECT
 ACCESS FOR EMERGENCY VEHICLES. FIRE DEPARTMENT ACCESS
 ROADS SHALL HAVE AN UNOBSTRUCTED WIDTH OF NOT LESS THAN
 20 FEET AND AN UNOBSTRUCTED VERTICAL CLEARANCE OF NOT
 LESS THAN 13 FEET 6 INCHES.
  
 PROVIDING A KNOX KEY SWITCH TO ALLOW ACCESS PASSED THE
 BARRIER MAY BE AN OPTION.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-10-13 Cont ID  
Sent By wjolin Date 2011-10-13 Time 08:33 Rev Time 0.00
Received By wjolin Date 2011-09-22 Time 12:26 Sent To  
Notes
2011-09-22 12:27:19TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date 2011-09-22 Cont ID  
Sent By rlecky Date 2011-08-15 Time 12:25 Rev Time 0.00
Received By rlecky Date 2011-07-29 Time 15:07 Sent To  
Notes
2011-07-29 15:07:18IN ZONING BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2011-10-07 Cont ID  
Sent By lfranco Date 2011-10-07 Time 19:07 Rev Time 0.00
Received By lfranco Date 2011-09-27 Time 10:06 Sent To  
Notes
2011-10-07 19:08:21PLANNING: *** PARKING COUNT TO REMAIN AS IS, NO
 REDUCTION OF PARKING STALLS ALLOWED ***

Review Stop Z ZONING
Rev No 1 Status F Date 2011-08-11 Cont ID  
Sent By lfranco Date 2011-08-11 Time 18:19 Rev Time 0.00
Received By lfranco Date 2011-08-01 Time 10:47 Sent To E
Notes
2011-08-11 18:30:40PLANNING AND ZONING: **** FAILED ****
  
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. THE PROJECT DESCRIPTION NOTES AN INSTALLATION OF A
 SECOND BARRIER GATE OPERATION AT MAIN ENTRANCE TO
 CONTROL EXISTING TRAFFIC AND REPAIR EXISTING
 NON-FUNCTIONAL ENTRANCE OPERATOR. DOES THIS BARRIER
 GATE OPERATOR ALSO HAVE CONTAINS A NEW GATE? THE
 OPERATOR SHOWS ON THE AERIALS SUBMITTED THAT IT WILL BE
 INSTALLED ON AN EXISTING PARKING SPACE OR LANDSCAPE
 INTERIOR ISLAND, IS THAT CORRECT? IF SO, PROVIDE A COPY
 OF A SITE PLAN WITH PARKING REQUIRED AND PROVIDED. IF
 THERE IS EXCESS PARKING TO WHAT IS REQUIRED FOR THE
 PROPERTY THEN A SPACE CAN BE USED FOR THE NEW OPERATOR.
 IF THE AREA IS A REQUIRED LANDSCAPE INTERIOR ISLAND
 WITH AN EXISTING TREE, THEN ANOTHER MORE SUITABLE AREA
 MAY NEED TO BE CONSIDERED. PROVIDE A LEGIBLE SITE PLAN
 SHOWING EXACT LOCATION OF NEW OPERATOR AND NEW GATE, IF
 APPLICABLE.
  
 PLEASE CONTACT ME TO DISCUSS FURTHER, IF YOU HAVE ANY
 QUESTIONS,
  
  
 LINDA MIA FRANCO, AICP
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  
  
  