Plan Review Details - Permit 11070649
Plan Review Stops For Permit 11070649
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2012-01-11 Cont ID  
Sent By rbrown Date 2012-01-11 Time 13:13 Rev Time 0.00
Received By rbrown Date 2012-01-11 Time 13:12 Sent To  
Notes
2012-01-11 15:01:14LETTER DATED 1/6/12 FROM MR. JORDY SOPOURN, ARCHITECT,
 GIVING METHOD OF STOREFRONT ATTACHMENT TO THE HOST
 STRUCTURE.
  
 DURING A TELEPHONE CONFERENCE CALL ON 1/11/12 WITH BEN
 HERD, G.C., MR. JORDY SOPOURN, ARCHITECT, STATED THAT
 HE WOULD SUBMIT A REVISED LETTER TO INCLUDE THE
 INTRODUCTION OF WOOD BACKING INSIDE THE METAL STUDS FOR
 THE BUCK ATTACHMENT. THIS WILL PROVIDE A BUCK
 ATTACHMENT THAT IS EQUIVALENT TO OR BETTER THAN THE
 ATTACHMENT REQUIRED BY MIAMI-DADE NOA# 06-1026.08 FOR
 THE STOREFRONT WHEN ATTACHED DIRECT TO A METAL FRAME
 STRUCTURE.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
  
 TELEPHONE: (561) 805 6652 ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-08-23 Cont ID  
Sent By shill Date 2011-08-23 Time 11:46 Rev Time 0.00
Received By shill Date 2011-08-23 Time 11:46 Sent To  
Notes
2011-08-24 12:05:58SEPARATE PERMIT REQUIRED FOR ENTRY DOOR
 (NOA SUBMITTED DOES NOT INCLUDE PANIC DEVICE)
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-08-03 Cont ID  
Sent By shill Date 2011-08-03 Time 13:38 Rev Time 0.00
Received By shill Date 2011-08-03 Time 13:38 Sent To  
Notes
2011-08-03 14:05:08****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. SEE DOORS FROM OFFICE TO RESTROOM VESTIBULE. FBC
 11-4.13.7, TWO DOORS IN A SERIES TO HAVE 48" PLUS THE
 WIDTH OF THE DOOR. SEE ALSO FBC FIGURE 11-25.
  
 2. N/A.
  
 3. PROVIDE ROOF STAND PRODUCT APPROVALS. INDICATE WHICH
 OPTION IS TO BE USED. DESIGN PROFESSIONAL TO SPECIFY
 DESIGN PRESSURES, FBC1603.1.4.
  
 4. DETAIL 2-A400.1 SHOWS AN EXTERIOR DOOR DETAIL,
 EXTERIOR WALL DETAIL (MARKED 11-A500.1, BUT SHOWN ON
 A400.1). IF THIS IS INCLUDED IN THE SCOPE OF WORK,
 PROVIDE PRODUCT APPROVALS, NOTE ON PLAN, AND INCLUDE IN
 PERMIT VALUATION.
  
 5. PERMIT VALUATION IS TO INCLUDE ALL LABOR AND
 MATERIALS, INCLUDING ANY FIXED EQUIPMENT. PLEASE
 INCLUDE ALL INSTALLED ITEMS PROVIDED BY OWNER.
  
 PLEASE FEEL FREE TO CONTACT ME TO DISCUSS.
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-08-08 Cont ID  
Sent By rlecky Date 2011-08-08 Time 10:23 Rev Time 0.00
Received By rlecky Date 2011-08-08 Time 09:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-08-05 Cont ID  
Sent By wjolin Date 2011-08-05 Time 09:54 Rev Time 0.00
Received By wjolin Date 2011-08-04 Time 14:48 Sent To  
Notes
2011-08-04 15:35:39330 CLEMATIS STREET #107
 PERMIT #11070649
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 MAIN ENTRY IS PERMITTED TO BE EQUIPPED WITH PANIC
 HARDWARE OR A KEYED LOCK WITH LOCK/UNLOCK INDICATOR
 WINDOW AND SIGNAGE STATING THE DOOR IS TO REMAIN
 UNLOCKED DURING BUSINESS HOURS. A THUMB TURN LOCK IS
 NOT PERMITTED.
  
 DEEP FAT FRYERS SHALL BE EQUIPPED WITH A SEPARATE
 HIGH-LIMIT CONTROL IN ADDITION TO THE ADJUSTABLE
 THERMOSTAT TO SHUT OFF FUEL OR ENERGY WHEN THE FAT
 TEMPERATURE REACHES 475F DEGREES AT 1 INCH BELOW THE
 SURFACE.
  
 ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS
 OF NFPA 241. TRASH AND DEBRIS IS TO BE REMOVED FROM THE
 SITE DAILY.
  
 FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE APPROVED AND SUBMITTED IN WRITING TO THE OFFICE OF
 THE FIRE MARSHAL.
  
 PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY
 RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING
 NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM
 WWW.KNOXBOX.COM.
  
 NOTE: DRAWINGS WILL BE STAMPED, INITIALED, AND DATED BY
 THE FIRE DEPARTMENT AFTER ALL PLAN REVIEWER COMMENTS
 HAVE BEEN SATISFIED.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2011-08-04 Cont ID  
Sent By lwagner Date 2011-08-04 Time 09:51 Rev Time 0.00
Received By lwagner Date 2011-08-04 Time 09:38 Sent To  
Notes
2011-08-04 09:52:14SEPERATE GAS PERMIT REQUIRED

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-08-23 Cont ID  
Sent By shill Date 2011-08-23 Time 12:58 Rev Time 0.00
Received By shill Date 2011-08-19 Time 13:14 Sent To  
Notes
2011-08-23 12:59:018/23 ON SH DESK FOR PROCESSING (NEED TO SWAP SHEETS)
  
2011-08-19 13:30:26GAVE TO SAMANTHA

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-08-09 Cont ID  
Sent By shill Date 2011-08-09 Time 11:00 Rev Time 0.00
Received By shill Date 2011-07-27 Time 09:44 Sent To  
Notes
2011-07-27 09:44:40**************EXPEDITED**************
 B--12

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2011-08-09 Cont ID  
Sent By shill Date 2011-08-09 Time 10:58 Rev Time 0.00
Received By shill Date 2011-08-09 Time 10:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-08-23 Cont ID  
Sent By shill Date 2011-08-23 Time 12:58 Rev Time 0.00
Received By shill Date 2011-08-23 Time 12:58 Sent To  
Notes
2011-08-23 12:58:37PER HM

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-08-01 Cont ID  
Sent By shill Date 2011-08-01 Time 14:39 Rev Time 0.00
Received By hmoser Date 2011-08-01 Time 14:39 Sent To  
Notes
2011-08-01 15:20:19****CORRECTIONS****
  
 1. SEPARATE PERMITS REQUIRED FOR THE HOOD, OOLERS AND
 ANSUL SYSTEM (ADVISORY ONLY).
  
 2. AHU 1, GRILL SIZES NOT PROVIDED FOR THE 10" DUCTS,
 SHEET M1.1.
  
 3. UNABLE TO LOCATE FRESH AIR FOR UNIT AHU1 ON SHEET
 M1.1. AHU2 INCLUDES A NOTE REGARDING MOTORIZED DAMPER.
 SHEET M1.2 SHOWS INTAKE ON ROOF, BUT NO OTHER
 INFORMATION PROVIDED, PLEASE SHOW COMPLIANCE WITH FBC
 13.409.AB.3.3.
  
 4. SHEET M1.1, NOTE 14 REQUIRES VEF TO OPERATE AT 78,
 M2.3 STATES FANS WILL TURN ON AT 85. PLEASE CORRELATE.
 FBC MECHANICAL 507, EVIDENCE THAT THE FANS WILL OPERATE
 WITH THE EQUIPMENT WILL BE REQUIRED AT INSPECTION.
  
 5. THERE ARE TWO UNITS MARKED AHU2, APPEARS THAT AHU1
 IS MISMARKED ON SHEET M1.1.
  
 6. KEY NOTES HVAC, SHEET M1.1, INCLUDE TWO NOTE 8S, TWO
 NOTE 12S. PLEASE REVISE SO EACH NOTE HAS A UNIQUE
 NUMBER.
  
 7. THE VALUE ON THE PERMIT APPLICATION IS TO INCLUDE
 ALL LABOR AND MATERIALS. NOTES ON SHEET M2.2 MAKE
 REFERENCE TO ITEMS SUPPLIED BY OWNER. PLEASE INCLUDE
 ALL LABOR AND MATERIAL, INCLUDING MATERIAL PROVIDED BY
 OWNER.
  
 HAROLD MOSER, MECHANICAL PLANS EXAMINER
 561-805-6732
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-08-04 Cont ID  
Sent By lwagner Date 2011-08-04 Time 09:51 Rev Time 0.00
Received By lwagner Date 2011-08-03 Time 10:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2011-08-08 Cont ID  
Sent By aaponte Date 2011-08-08 Time 16:10 Rev Time 0.00
Received By aaponte Date 2011-08-08 Time 16:10 Sent To  
Notes
***NONE***