Plan Review Details - Permit 11070617
| Plan Review Stops For Permit 11070617 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2012-03-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-03-05 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-03-05 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2012-03-02 16:30:54 | SEPERATE ROOFING PERMIT REQUIRED SEE UNKNOWNS BELOW | | | IDENTIFIED AS (*******) | | | | | | ROOFING REPORTS SUBMITTED: | | | | | | BERRIDGE MANUFACTURING CO ZEE-LOCK PANEL W/ CONTINUOUS | | | CLIP | | | NOA 10-1018.02 | | | PAGE 5 OF 7 TABLE B FIELD -168.5 PERIMETERS & CORNER | | | -176 PSF | | | | | | | | | JOHN MANVILLE INSULATION BOARD | | | NOA 09-0219.09 | | | SUBSYSTEM OR TRADE NAME OF SYSTEM NOT | | | PROVIDED.************************** | | | | | | | | | DUROLAST SINGLE PLY PVC ROOF SYSTEM OVER CONCRETE DECK | | | NOA 07-1018.10 | | | PAGE 6 OF 14 | | | DECK TYPE 31 | | | SYSTEM A(2) | | | MAX PRESSURE -247.5 LIMITATION #9. | | | | | | DURO-LAST SINGLE PLY PVC ROOF SYSTEM OVER WOOD DECK | | | NOA 07-1018.14 | | | PAGE 6 OF 10 | | | DECK TYPE 1I | | | SYSTEM C: | | | MAXIMUM DESIN PRESSURES 45-60 PSF NOT IDENTIFIED | | | LIMITATION # 7 ********************************** | | | ******************************************************* | | | *************************************** | | | | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS | | | PLAN PRIOR TO INSPECTION WILL RESULT IN FAILED | | | INSPECTION(S) AND THE ASSESSMENT OF RE-INSPECTION | | | FEE(S). REVISIONS REQUIRE ADDITIONAL REVIEWS WITH | | | ASSOCIATED FEES. | | | | | | 1) SHEET 1-A1.1 INDICATES A NEW MEZZANINE LEVEL AND | | | HIGH RACK STORAGE SYSTEM. THE PLANS DON'T | | | HAVE ANY DETAILS FOR THE STRUCTURAL COMPONENTS FOR | | | EITHER SECTION. A REVISION WILL BE REQUIRED | | | INDICATING CODE COMPLIANCE FOR BOTH OF THE AREAS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2012-02-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-02-01 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-02-01 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2012-02-01 14:40:00 | BUILDING PLAN REVIEW | | | PERMIT: 11070617 | | | ADD: 2301 OKEECHOBEE BLVD, BLDG# 1 | | | CONT: NORTH AMERICAN AUTOMOTIVE SERVICES | | | TEL: (630)352-8126 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | 2007 FLORIDA EXISTING BUILDING CODE W/ 2009 FBC | | | SUPPLEMENTS | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | | | | BLDG TYPE IB -NON SPRINKLERED | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1) 2007 EXST BLD CODE 601.2 CONFORMANCE. AN EXISTING | | | BUILDING OR PORTION THEREOF SHALL NOT BE ALTERED SUCH | | | THAT THE BUILDING BECOMES LESS SAFE OR ENERGY EFFICIENT | | | THAN ITS EXISTING CONDITION. IF IN THE ALTERATION THE | | | CURRENT LEVEL OF SAFETY OR SANITATION IS TO BE REDUCED, | | | THE PORTION ALTERED SHALL CONFORM TO THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING . | | | | | | 1A) SHEET 1-A1.0 THE PLANS APPEAR TO HAVE A OCCUPANCY | | | SEPARATION WALL BETWEEN THE AUTOMOBILE REPAIR GARAGE | | | AND PARTS STORAGE AND THE REPAIR GARAGE AND MERCANTILE | | | OCCUPANCY. IT APPEARS TO BE A MASONRY OPENING NOT | | | PROTECTED RIGHT OF DOOR # 1118? | | | | | | 1B) THE ABOVE MENTIONED OCCUPANCY SEPARATION WALL IS | | | THE ONLY OCCUPANCY SEPARATION WALL SHOWN ON THE PLANS, | | | THERE WOULD APPEAR A OCCUPANCY SEPARATION WALL WOULD BE | | | REQUIRED BETWEEN THE PARTS STORAGE AREA AND THE | | | MERCANTILE OCCUPANCY. PLEASE PROVIDE THE FOLLOWING FOR | | | A MIXED OCCUPANCY, IF THIS BUILDING IS TO BE CONSIDERED | | | SEPARATED (FBC-B 508.3.1.3 OR NON-SEPARATED 508.3.2 OR | | | IF MEETING THE REQUIREMENTS FOR ACCESSORY OCCUPANCIES | | | 508.3.1. | | | PLEASE NOTE THAT BOTH THE FIRST FLOOR AND MEZZANINE | | | SQUARE FOOT LEVELS ARE TO BE TOTALED TOGETHER FOR TOTAL | | | SQ FT FOR THIS FIRE LOAD & OCCUPANCY IT APPEARS THE | | | PARTS STORAGE AREA IS WELL OVER THE 10% OF THE TOTAL | | | FLOOR AREA . | | | | | | 1C) THE WALL BETWEEN THE PARTS AND SHOWROOM SHOULD ALSO | | | BE A FIRE RATED WALL PER TABLE TABLE 508.3.3 FOOTNOTE B | | | INDICATES AREA REQUIREMENTS REQUIRING SEPERATION AS | | | WELL AS TABLE 508.2 INCIDENTAL USE AREAS FOR STORAGE | | | ROOMS GREATER THAN 100 SQ FT IN UNSPRINKLERED | | | BUILDINGS. | | | | | | 2) THE SECOND ISSUE WITH THE PARTS STORAGE FIRE AREA | | | WHICH INCLUDES APPROX. 4000 SQ FT (3789 SQ FT) FIRST | | | FLOOR PLUS 3015 SQ FT ON THE PARTS MEZZANINE (VENDOR | | | INSTALLED). | | | SEE FBC-B 505.2 AREA LIMITATIONS FOR MEZZANINE | | | ALLOWABLE FLOOR AREA. | | | | | | 2A) THIS IS A STORAGE OCCUPANCY IN A BUILDING TYPE L-B. | | | PLEASE REVIEW FBC-B MEZZANINE AREA LIMITATION 505.2 | | | EXCEPTION# 2. THE AGGREGATE AREA OF MEZZANINES IN | | | BUILDINGS AND STRUCTURES OF TYPE I OR II CONSTRUCTION | | | SHALL NOT EXCEED ONE-HALF OF THE FLOOR AREA OF THE ROOM | | | IN BUILDINGS AND STRUCTURES EQUIPPED THROUGHOUT WITH AN | | | APPROVED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH | | | SECTION 903.3.1.1 AND AN APPROVED EMERGENCY VOICE/ALARM | | | COMMUNICATION SYSTEM IN ACCORDANCE WITH SECTION | | | 907.2.12.2. | | | | | | THE MEZZANINE LEVEL WILL NEED TO BE REDUCED OR IT WILL | | | BE REQUIRED TO BE CONSIDERED A SECOND FLOOR AND TO MEET | | | ALL BUILDING & MEANS OF EGRESS OF A SECOND FLOOR. | | | | | | 2B) THE COMMENT VENDOR INSTALLED, IS THIS A | | | PRE-ENGINEERED SYSTEM? THE LIVE LOADS FOR ANY STORAGE | | | AREA ABOVE THE GROUND FLOOR WILL NEED TO BE PROVIDED. | | | 2007/09 FBC-B T 1607.1 | | | LIGHT 125 PSF AND HEAVY 250 PSF. PLEASE PROVIDE | | | ENGINEERING. | | | | | | 2B)(1) 110.4.2 STORAGE & FACTORY- INDUSTRIAL | | | OCCUPANCIES. IT SHALL BE THE RESPONSIBILITY OF THE | | | OWNER, AGENT, PROPIETOR OR OCCUPANT OF GROUP S AND | | | GROUP F OCCUPANCIES, OR ANY OCCUPANCY WHERE EXCESSIVE | | | FLOOR LOADING IS LIKELY TO OCCUR, TO EMPLOY A COMPETENT | | | ARCHITECT OR ENGINEER IN COMPUTING THE SAFE FLOOR LOAD | | | CAPACITY. ALL SUCH COMPUTATIONS SHALL BE ACCOMPANIED BY | | | AN AFFADAVIT FROM THE ARCHITECT OR ENGINEER STATING THE | | | SAFE ALLOWABLE FLOOR LOADS ON EACH FLOOR IN POUNDS PER | | | SQ FT.THE | | | COMPUTATIONS & AFFADAVIT SHALL BE FILED AS A PERMANENT | | | RECORD OF THE BLDG DEPT. | | | | | | | | | 2B)(2) 110.4.3.SIGNS REQUIRED. IN EVERY BUILDING OR | | | PART OF A BUILDING USED FOR STORAGE, INDUSTRIAL OR | | | HAZARDOUS PURPOSES, THE SAFE FLOOR LOADS, AS REVIEWED | | | BY THE BUILDING OFFICIAL ON THE PLAN, SHALL BE MARKED | | | ON PLATES OF APPROVED DE SIGN WHICH SHALL BE SUPPLIED & | | | SECURELY AFFIXED BY THE OWNER OF THE BUILDING IN A | | | CONSPICUOUS PLACE IN EACH STORY TO WHICH THEY RELATE. | | | SUCH PLATES SHALL NOT BE REMOVED OR DEFACED, & IF LOST, | | | REMOVED THE OWNER OF THE BUILDING SHALL REPLACE THEM. | | | | | | 2C) SHEET 1-A1.0 PLANS ARE DEFICIEENT IN AN OCCUPANCY | | | SEPERATION WALL BETWEEN THE PARTS DEPARTMENT (STORAGE | | | OCCUPANCY) AND OFFICE AREAS (BUSINESS OCCUPANCY). | | | | | | 3) THE AREA OF CONCERN IS FOUND ON 1-A 1.0 &1-A1.1 A | | | BUSINESS MEZZANINE, A TRUE SECOND FLOOR AREA WITH ONLY | | | ONE MEANS OF EGRESS. PLEASE PROVIDE: | | | | | | 3A) THE PLANS INDICATE A WALL TYPE N WHICH IS INDICATED | | | ON 0-A1.0 AS A NON RATED WALL. | | | | | | 3B) PLEASE PROVIDE THE SQUARE FOOTAGE OF MEZZANINE AND | | | THE SQUARE FOOTAGE OF OPEN AREA | | | THAT COMMUNICATES WITH THIS AREA. FBC-B 505.2 & 505.4. | | | IF THIS IS NOT A TRUE MEZZANINE THEN ISSUES WILL ARISE | | | FROM THE OPEN STAIR THAT SERVES THIS AREA. THIS AREA | | | WAS DISCUSSED PREVIOUSLY AS HOW TO HANDLE THIS | | | PRE-EXISTING CONDITION. ALSO DOOR # 1127A WAS RED LINED | | | ON THE SEEET OF PLANS THAT WAS READY FOR ISSUANCE, IT | | | SWINGS THE WRONG WAY FOR EGRESS FROM THE 2ND FLOOR | | | LEVEL AND EGRESS PATERN FROM THE PARTS DEPARTMENT. | | | | | | 4) SHEET 1-A8.1 DETAILS A & 1AND SHEET 1-A8.2 BOTH | | | INDICATE THE USE OF ? INCH EXTERIOR GRADE PLYWOOD FOR | | | SHEATHING, PLEASE REVIEW: | | | FBC-B | | | | | | | | | | | | 603.1 ALLOWABLE MATERIALS. COMBUSTIBLE MATERIALS SHALL | | | BE PERMITTED IN BUILDINGS OF TYPE I OR TYPE II | | | CONSTRUCTION IN THE FOLLOWING APPLICATIONS AND IN | | | ACCORDANCE WITH SECTIONS 603.1.1 THROUGH 603.1.3: | | | 1. FIRE-RETARDANT-TREATED WOOD SHALL BE PERMITTED IN: | | | 1.1. NONBEARING PARTITIONS WHERE THE REQUIRED | | | FIRE-RESISTANCE RATING IS 2 HOURS OR LESS. | | | 1.2. NONBEARING EXTERIOR WALLS WHERE NO FIRE RATING IS | | | REQUIRED. | | | | | | 5) PLEASE REVIEW SHEET 1-A8.0 DETAIL # 1 INDICATES THE | | | USE OF EXISTING WOOD TRUSSES, ARE THESE TRUSSES FIRE | | | RETARDANT TREATED WOOD? THE PLANS DO NOT ADDRESS THE | | | VERTICAL PLYWOOD, IF IT IS FIRE RETARDANT TREATED WOOD? | | | TYPE I TYPE II BUILFINGS. FBC 603.1. | | | | | | 6) SHEET 1-A8.1 WALL SECTION 1 ALSO HAS REFRENECE TO | | | 3/4 INCH PLYWOOD, NOT FIRE RETARDANT TREATED WOOD. | | | 603.1. | | | | | | 7) THE ROOFING APPROVAL 07-1018.10 DURO-LAST SINGLE PLY | | | PVC ROOFING SYSTEMS OVER CONCRETE DECKS THIS REPORT HAS | | | SUBSYSTEM AND WILL NEED TO CIRCLE WHICH SUBSYSTEM WILL | | | BE INSTALLED. PLEASE REVIEW THE DESIGN PRESSURES | | | ASSOCIATED WITH EACH SUBSYSTEM AND IF LIMITATION 7 OR | | | LIMITATION 9 ARE APPLICABLE. IF LIMITATION 7 IS | | | INDICATED AND ENHANCED FASTENING IS REQUIRED IN ZONES 2 | | | & 3 PLEASE PROVIDE CALCULATIONS. | | | | | | 8) THE ABOVE MENTIONED NOA 07-1018.10 IS FOR PVC ROOF | | | SYSTEMS OVER CONCRETE DECKS. | | | SHEET 1-A8.2 INDICATES NEW TOWER SECTIONS THAT WILL | | | NEED A SEPARATE ROOFING PRODUCT APPROVAL FOR THIS TYPE | | | OF ROOFING APPLICATION. | | | | | | 9) DEPENDING ON THE SHEATHING FROM COMMENT #7 THE | | | REYNOLDS REYNOBOND COMPOSITE PANEL NOA 10-1118.05 MAY | | | NEED AN ENGINEERS ANALYSIS FOR THE TYPE OF SHEATHING TO | | | BE INSTALLED SINCE THE PRESSURES ASSOCIATED WITH THIS | | | REPORT ARE FROM 5/8 INCH PLYWOOD SHEATHING. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-10-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-05 |
Time |
11:20 |
Rev Time |
1.20 |
| Received By |
jwitmer |
Date |
2011-10-05 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2011-10-05 11:20:59 | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 11070617 | | | ADD: 2301 OKEECHOBEE BLVD, BLDG# 1 | | | CONT: NORTH AMERICAN AUTOMOTIVE SERVICES | | | TEL: (630)352-8126 | | | | | | 1A) PARTS MEZZANINE IS TO BE A PRE-ENGINEERED SYSTEM | | | VENDOR INSTALLED, UNDER A SEPARATE PERMIT, REVIEW AND | | | ASSOCIATED FEES. | | | | | | 1B) 110.4.2 STORAGE & FACTORY- INDUSTRIAL OCCUPANCIES. | | | IT SHALL BE THE RESPONSIBILITY OF THE OWNER, AGENT, | | | PROPRIETOR OR OCCUPANT OF GROUP S AND GROUP F | | | OCCUPANCIES, OR ANY OCCUPANCY WHERE EXCESSIVE FLOOR | | | LOADING IS LIKELY TO OCCUR, TO EMPLOY A COMPETENT | | | ARCHITECT OR ENGINEER IN COMPUTING THE SAFE FLOOR LOAD | | | CAPACITY. ALL SUCH COMPUTATIONS SHALL BE ACCOMPANIED BY | | | AN AFFIDAVIT FROM THE ARCHITECT OR ENGINEER STATING THE | | | SAFE ALLOWABLE FLOOR LOADS ON EACH FLOOR IN POUNDS PER | | | SQ FT. THE | | | COMPUTATIONS & AFFIDAVIT SHALL BE FILED AS A PERMANENT | | | RECORD OF THE BLDG DEPT. | | | | | | | | | 1C) 110.4.3.SIGNS REQUIRED. IN EVERY BUILDING OR PART | | | OF A BUILDING USED FOR STORAGE, INDUSTRIAL OR HAZARDOUS | | | PURPOSES, THE SAFE FLOOR LOADS, AS REVIEWED BY THE | | | BUILDING OFFICIAL ON THE PLAN, SHALL BE MARKED ON | | | PLATES OF APPROVED DE SIGN WHICH SHALL BE SUPPLIED & | | | SECURELY AFFIXED BY THE OWNER OF THE BUILDING IN A | | | CONSPICUOUS PLACE IN EACH STORY TO WHICH THEY RELATE. | | | SUCH PLATES SHALL NOT BE REMOVED OR DEFACED, & IF LOST, | | | REMOVED THE OWNER OF THE BUILDING SHALL REPLACE THEM. | | | | | | 2) ROOFING APPROVALS: | | | | | | NOA: 07-1018.10 | | | DURO-LAST SINGLE PLY PVC ROOFING SYSTEM OVER CONCRETE | | | DECK, | | | PAGE 5, DECK TYPE 31 CONCRETE DECK INSULATED -217.5 | | | LIMITATION # 9 | | | | | | NOA 09-0219.09 | | | JOHN MANVILLE ROOF INSULATION BOARD | | | ROOF ASSEMBLIES ARE APPROVED UNDER SPECIFIC ROOF | | | COVER?S PRODUCT NOA. | | | | | | NOA 07-1018.14 | | | DURO-LAST SINGLE PLY PVC ROOFING SYSTEM OVER WOOD DECK | | | THE INDIVIDUAL SUB-SYSTEMS ARE NOT IDENTIFIED, ROOFING | | | CONTRACTOR WILL NEED TO | | | IDENTIFY SUB-SYSTEM AND IF LIMITATION # 7 APPLIES THEN | | | ENHANCED FASTENING IN ZONES | | | 2 & 3 WILL NEED TO BE CALCULATED AND PREPARED BY EITHER | | | A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR | | | REGISTERED ARCHITECT. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-08-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-08-09 |
Time |
14:34 |
Rev Time |
6.50 |
| Received By |
jwitmer |
Date |
2011-08-03 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2011-08-09 14:35:15 | BUILDING PLAN REVIEW | | | PERMIT: 11070617 | | | ADD: 2301 OKEECHOBEE BLVD, BLDG# 1 | | | CONT: NORTH AMERICAN AUTOMOTIVE SERVICES | | | TEL: (630)352-8126 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | 2007 FLORIDA EXISTING BUILDING CODE W/ 2009 FBC | | | SUPPLEMENTS | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) 2007 EXST BLD CODE 601.2 CONFORMANCE. AN EXISTING | | | BUILDING OR PORTION THEREOF SHALL NOT BE ALTERED SUCH | | | THAT THE BUILDING BECOMES LESS SAFE OR ENERGY EFFICIENT | | | THAN ITS EXISTING CONDITION. IF IN THE ALTERATION THE | | | CURRENT LEVEL OF SAFETY OR SANITATION IS TO BE REDUCED, | | | THE PORTION ALTERED SHALL CONFORM TO THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING . | | | | | | 1A) SHEET 1-A1.0 THE PLANS APPEAR TO HAVE A OCCUPANCY | | | SEPARATION WALL BETWEEN THE AUTOMOBILE REPAIR GARAGE | | | AND PARTS STORAGE AND THE REPAIR GARAGE AND MERCANTILE | | | OCCUPANCY. IT APPEARS TO BE A MASONRY OPENING NOT | | | PROTECTED NEXT TO DOOR # 1118? | | | | | | 1B) THE ABOVE MENTIONED OCCUPANCY SEPARATION WALL IS | | | THE ONLY OCCUPANCY SEPARATION WALL SHOWN ON THE PLANS, | | | THERE WOULD APPEAR A OCCUPANCY SEPARATION WALL WOULD BE | | | REQUIRED BETWEEN THE PARTS STORAGE AREA AND THE | | | MERCANTILE OCCUPANCY. PLEASE PROVIDE THE FOLLOWING FOR | | | A MIXED OCCUPANCY, IF THIS BUILDING IS TO BE CONSIDERED | | | SEPARATED (FBC-B 508.3.1.3 OR NON-SEPARATED 508.3.2 OR | | | IF MEETING THE REQUIREMENTS FOR ACCESSORY OCCUPANCIES | | | 508.3.1. | | | PLEASE NOTE THAT BOTH THE FIRST FLOOR AND MEZZANINE | | | SQUARE FOOT LEVELS ARE TO BE TOTALED TOGETHER FOR TOTAL | | | SQ FT FOR THIS FIRE LOAD & OCCUPANCY IT APPEARS THE | | | PARTS STORAGE AREA IS WELL OVER THE 10% OF THE TOTAL | | | FLOOR AREA . | | | | | | 2) THE SECOND ISSUE WITH THE PARTS STORAGE FIRE AREA | | | WHICH INCLUDES APPROX. 4000 SQ FT FIRST FLOOR PLUS 3015 | | | SQ FT ON THE PARTS MEZZANINE (VENDOR INSTALLED). | | | | | | 2A) THIS IS A STORAGE OCCUPANCY IN A BUILDING TYPE L-B. | | | PLEASE REVIEW FBC-B MEZZANINE AREA LIMITATION 505.2 | | | EXCEPTION# 2. THE AGGREGATE AREA OF MEZZANINES IN | | | BUILDINGS AND STRUCTURES OF TYPE I OR II CONSTRUCTION | | | SHALL NOT EXCEED ONE-HALF OF THE FLOOR AREA OF THE ROOM | | | IN BUILDINGS AND STRUCTURES EQUIPPED THROUGHOUT WITH AN | | | APPROVED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH | | | SECTION 903.3.1.1 AND AN APPROVED EMERGENCY VOICE/ALARM | | | COMMUNICATION SYSTEM IN ACCORDANCE WITH SECTION | | | 907.2.12.2. | | | | | | THE MEZZANINE LEVEL WILL NEED TO BE REDUCED OR IT WILL | | | BE REQUIRED TO BE CONSIDERED A SECOND FLOOR AND TO MEET | | | ALL BUILDING & MEANS OF EGRESS OF A SECOND FLOOR. | | | | | | 2B) THE COMMENT VENDOR INSTALLED, IS THIS A | | | PRE-ENGINEERED SYSTEM? THE LIVE LOADS FOR ANY STORAGE | | | AREA ABOVE THE GROUND FLOOR WILL NEED TO BE PROVIDED. | | | 2007/09 FBC-B T 1607.1 | | | LIGHT 125 PSF AND HEAVY 250 PSF. PLEASE PROVIDE | | | ENGINEERING. | | | | | | 2B)(1) 110.4.2 STORAGE & FACTORY- INDUSTRIAL | | | OCCUPANCIES. IT SHALL BE THE RESPONSIBILITY OF THE | | | OWNER, AGENT, PROPIETOR OR OCCUPANT OF GROUP S AND | | | GROUP F OCCUPANCIES, OR ANY OCCUPANCY WHERE EXCESSIVE | | | FLOOR LOADING IS LIKELY TO OCCUR, TO EMPLOY A COMPETENT | | | ARCHITECT OR ENGINEER IN COMPUTING THE SAFE FLOOR LOAD | | | CAPACITY. ALL SUCH COMPUTATIONS SHALL BE ACCOMPANIED BY | | | AN AFFADAVIT FROM THE ARCHITECT OR ENGINEER STATING THE | | | SAFE ALLOWABLE FLOOR LOADS ON EACH FLOOR IN POUNDS PER | | | SQ FT.THE | | | COMPUTATIONS & AFFADAVIT SHALL BE FILED AS A PERMANENT | | | RECORD OF THE BLDG DEPT. | | | | | | | | | 2B)(2) 110.4.3.SIGNS REQUIRED. IN EVERY BUILDING OR | | | PART OF A BUILDING USED FOR STORAGE, INDUSTRIAL OR | | | HAZARDOUS PURPOSES, THE SAFE FLOOR LOADS, AS REVIEWED | | | BY THE BUILDING OFFICIAL ON THE PLAN, SHALL BE MARKED | | | ON PLATES OF APPROVED DE SIGN WHICH SHALL BE SUPPLIED & | | | SECURELY AFFIXED BY THE OWNER OF THE BUILDING IN A | | | CONSPICUOUS PLACE IN EACH STORY TO WHICH THEY RELATE. | | | SUCH PLATES SHALL NOT BE REMOVED OR DEFACED, & IF LOST, | | | REMOVED THE OWNER OF THE BUILDING SHALL REPLACE THEM. | | | | | | 3) THE OTHER AREA OF CONCERN IS FOUND ON 1-A1.1 A | | | BUSINESS MEZZANINE. PLEASE PROVIDE: | | | | | | 3A) THE PLANS INDICATE A WALL TYPE M & N WHICH ARE NOT | | | FOUND ON 0-A1.0. | | | | | | 3B) PLEASE PROVIDE THE SQUARE FOOTAGE OF MEZZANINE AND | | | THE SQUARE FOOTAGE OF OPEN AREA | | | THAT COMMUNICATES WITH THIS AREA. FBC-B 505.2 & 505.4. | | | IF THIS IS NOT A TRUE MEZZANINE THEN ISSUES WILL ARISE | | | FROM THE OPEN STAIR THAT SERVES THIS AREA. | | | | | | 4) BUSINESS MEZZANINE LEVEL WAS BUILT BEFORE THE ADA & | | | FLORIDA ACCESSIBILITY CODE WERE IN ACTED. PLEASE | | | PROVIDE COMPLIANCE WITH FBC-B 11-4.1.6(1)(K) III) | | | NOTHING IN THIS SECTION SHALL BE CONSTRUED TO RELIEVE | | | THE OWNER OF ANY BUILDING, STRUCTURE OR FACILITY FROM | | | THE DUTY TO PROVIDE VERTICAL ACCESSIBILITY TO ALL | | | LEVELS ABOVE AND BELOW OCCUPIABLE GRADE LEVEL, | | | REGARDLESS OF WHETHER THE CODE REQUIRES AN ELEVATOR TO | | | BE INSTALLED IN SUCH BUILDING, STRUCTURE, OR FACILITY, | | | EXCEPT FOR: (1) ELEVATOR PITS, ELEVATOR PENTHOUSES, | | | MECHANICAL ROOMS, PIPING OR EQUIPMENT CATWALKS, AND | | | AUTOMOBILE LUBRICATION AND MAINTENANCE PITS AND | | | PLATFORMS; (2) UNOCCUPIABLE SPACES, SUCH AS ROOMS, | | | ENCLOSED SPACES, AND STORAGE SPACES THAT ARE NOT | | | DESIGNED FOR HUMAN OCCUPANCY, FOR PUBLIC | | | ACCOMMODATIONS, OR FOR WORK AREAS; AND (3) OCCUPIABLE | | | SPACES AND ROOMS THAT ARE NOT OPEN TO THE PUBLIC AND | | | THAT HOUSE NO MORE THAN FIVE PERSONS INCLUDING, BUT NOT | | | LIMITED TO, EQUIPMENT CONTROL ROOMS AND PROJECTION | | | BOOTHS. HOWEVER, AS PROVIDED IN SECTION 553.509, | | | FLORIDA STATUTES, BUILDINGS, STRUCTURES, AND FACILITIES | | | MUST, AT A MINIMUM, COMPLY WITH THE REQUIREMENTS OF THE | | | ADAAG. THEREFORE, FACILITIES SUBJECT TO THE ADAAG MAY | | | BE REQUIRED TO PROVIDE VERTICAL ACCESS TO AREAS | | | OTHERWISE EXEMPT UNDER SECTION 11-4.1.3(5) OF THIS | | | CODE. | | | | | | 5) SHEET 1-A1.0 DOES INDICATE THE USE OF A LIFT TO GAIN | | | ACCESS TO THE RESTROOMS AND RETAIL AREAS, PLEASE | | | PROVIDE COMPLIANCE WITH 11-4.1.6(1) (B) IF EXISTING | | | ELEMENTS, SPACES, OR COMMON AREAS ARE ALTERED, THEN | | | EACH SUCH ALTERED ELEMENT, SPACE, FEATURE, OR AREA | | | SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF SECTION | | | 11-4.1.1 TO SECTION 11-4.1.3, MINIMUM REQUIREMENTS FOR | | | NEW CONSTRUCTION. IF THE APPLICABLE PROVISION FOR NEW | | | CONSTRUCTION REQUIRES THAT AN ELEMENT, SPACE, OR COMMON | | | AREA BE ON AN ACCESSIBLE ROUTE, THE ALTERED ELEMENT, | | | SPACE, OR COMMON AREA IS NOT REQUIRED TO BE ON AN | | | ACCESSIBLE ROUTE EXCEPT AS PROVIDED IN SECTION | | | 11-4.1.6(2), ALTERATIONS TO AN AREA CONTAINING A | | | PRIMARY FUNCTION. PLEASE PROVIDE MANUFACTURERS | | | SPECIFICATIONS. | | | | | | 6) SHEET 1-A1.0 SERVICE AREA AND NEW FIVE FOOT WIDE | | | CURB RAMP WILL NEED TO COMPLY WITH FBC-B 11-4.29 | | | DETECTABLE WARNINGS. | | | | | | 7) SHEET 1-A8.1 DETAILS A & 1AND SHEET 1-A8.2 BOTH | | | INDICATE THE USE OF ? INCH EXTERIOR GRADE PLYWOOD FOR | | | SHEATHING, PLEASE REVIEW: | | | FBC-B | | | | | | 603.1 ALLOWABLE MATERIALS. COMBUSTIBLE MATERIALS SHALL | | | BE PERMITTED IN BUILDINGS OF TYPE I OR TYPE II | | | CONSTRUCTION IN THE FOLLOWING APPLICATIONS AND IN | | | ACCORDANCE WITH SECTIONS 603.1.1 THROUGH 603.1.3: | | | 1. FIRE-RETARDANT-TREATED WOOD SHALL BE PERMITTED IN: | | | 1.1. NONBEARING PARTITIONS WHERE THE REQUIRED | | | FIRE-RESISTANCE RATING IS 2 HOURS OR LESS. | | | 1.2. NONBEARING EXTERIOR WALLS WHERE NO FIRE RATING IS | | | REQUIRED. | | | | | | 7) PLEASE SEE SHEET 1-A8.3 DETAIL A INDICATES THE USE | | | OF ? INCH OF RIGID COVER BOARD AND 2 INCHES OF POLYISO | | | INSULATION. THE NOA 10-1018.02 PAGE 4 INDICATES THE | | | INSULATION TO HAVE CURRENT NOA?S. | | | | | | 8) THE ROOFING APPROVAL 07-1018.10 DURO-LAST SINGLE PLY | | | PVC ROOFING SYSTEMS OVER CONCRETE DECKS THIS REPORT HAS | | | SUBSYSTEM AND WILL NEED TO CIRCLE WHICH SUBSYSTEM WILL | | | BE INSTALLED. PLEASE REVIEW THE DESIGN PRESSURES | | | ASSOCIATED WITH EACH SUBSYSTEM AND IF LIMITATION 7 OR | | | LIMITATION 9 ARE APPLICABLE. IF LIMITATION 7 IS | | | INDICATED AND ENHANCED FASTENING IS REQUIRED IN ZONES 2 | | | & 3 PLEASE PROVIDE CALCULATIONS. | | | | | | 9) THE ABOVE MENTIONED NOA 07-1018.10 IS FOR PVC ROOF | | | SYSTEMS OVER CONCRETE DECKS. | | | SHEET 1-A8.2 INDICATES NEW TOWER SECTIONS THAT WILL | | | NEED A SEPARATE ROOFING PRODUCT APPROVAL FOR THIS TYPE | | | OF ROOFING APPLICATION. | | | | | | 10) DEPENDING ON THE SHEATHING FROM COMMENT #7 THE | | | REYNOLDS REYNOBOND COMPOSITE PANEL NOA 10-1118.05 MAY | | | NEED AN ENGINEERS ANALYSIS FOR THE TYPE OF SHEATHING TO | | | BE INSTALLED SINCE THE PRESSURES ASSOCIATED WITH THIS | | | REPORT ARE FROM 5/8 INCH PLYWOOD SHEATHING. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2012-02-29 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-02-29 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-02-29 |
Time |
17:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2012-02-06 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-02-06 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-02-03 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2012-02-06 12:27:36 | 11070617 | | | 2310 OKEECHOBEE BLVD. | | | NAPLETON BLDG. 1 | | | | | | THE ELECTRICAL EQUIPMENT ROOM REQUIRES TWO ENTRANCES. | | | NEC 110.26(C)(2) | | | PROVIDE DEDICATED WORKING SPACE AND SAFETY CLEARANCES | | | FOR DISTRIBUTION PANELBOARD 1DPC. NEC 110.26 | | | PROVIDE A LABELING SCHEDULE FOR THE SAFETY SIGNAGE | | | REQUIRED FOR THE ELECTRICAL EQUIPMENT AND ELECTRICAL | | | ROOMS. NEC 110.22, 110.16 | | | | | | | | | ROBERT LECKY | | | ELECTRIC PLANS EXAMINER | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-09-27 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-09-27 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-09-27 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-08-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-08-17 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-08-10 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2011-08-17 10:44:57 | | | | BUILDING # 1 | | | RELOCATE THE MAIN BONDING JUMPER FOR BUILDING #1 TO THE | | | MAIN DISCONNECTS. NEC 250.24(B) | | | PROVIDE AN EQUIPMENT LAYOUT PLAN FOR THE COMPRESSOR | | | ROOM SHOWING THE ELECTRIC CIRCUITRY WITH DISCONNECTS | | | AND WORKING CLEARANCES. NEC 110.26, 215.5 | | | A SEPARATE PERMIT AND PLAN IS REQUIRED FOR THE SITE | | | LIGHTING. THE PLAN SHOULD INCLUDE PHOTO METRICS, THE | | | DESIGN WIND LOAD ENGINEERED FOR THE LIGHT POLES AND AN | | | ELECTRIC POWER PLAN. | | | A SEPARATE PERMIT AND PLAN IS REQUIRED FOR THE CAR WASH | | | EQUIPMENT | | | | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2012-05-30 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2012-05-30 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2012-05-30 |
Time |
|
Sent To |
|
|
| Notes |
| 2012-05-30 13:58:47 | PLANS ARE APPROVED WITH PROVISOS (RESPOND TO ALL | | | COMMENTS IN WRITING IN ACKNOWLEDGEMENT) | | | | | | #1 RIGHT TURN ONLY EXIT CONCRETE APRON UNTO CONGRESS | | | AVE NEEDS TO BE REVISED AND NARROWED TO AVOID CARS | | | ENTERING SITE WHILE OTHERS ARE TRYING TO EXIT. | | | (CONGRESS AVENUE IS A PALM BEACH COUNTY ROADWAY | | | THEREFORE CONSULT WITH PBC ROAD ROW PERMIT WILL BE | | | REQUIRED) | | | | | | #2 PROVIDE DETAILS AND/OR DESIGN SUMMARY FOR PROPOSED | | | A.D.A. RAMP. (PLANS SUBMITTED DO NOT SHOW SLOPE, | | | SPECIFIC DIMENSIONS (LENGTH, WIDTH, ETC.) AND DETAILS | | | FOR A.D.A. HANDRAIL. (RAMP DETAILS MAY BE OBTAINED THRU | | | WWW.ADA.ORG WEB SITE UNDER U.S. DEPARTMENT OF JUSTICE - | | | ADA STANDARDS FOR ACCESSIBLE DESIGN. IF PERMIT FOR THIS | | | ELEMENT HAS BEEN ISSUED UNDER ARCHITECTURE PLANS OR | | | OTHER SOURCE PLEASE PROVIDE PERMIT NUMBER AND/OR | | | INFORMATION. | | | | | | #3 PLAN IDENTIFIES TWO DUMPSTER AREAS; HOWEVER THESE | | | AREAS ARE NOT LOCATED IN THE SAME VICINITY. PLEASE | | | SPECIFY WHICH DUMPSTER WILL BE THE PRIMARY DUMPSTER FOR | | | CITY OF WEST PALM BEACH SANITATION PICK-UP. | | | | | | #4 PLEASE VERIFY THAT THE 2" DOMESTIC METER (LOCATION: | | | CONGRESS SIDEWALK 10 NORTH OF SOUTH DRIVE) HAS THE | | | PROPER BACKFLOW PREVENTION DEVICE. INACTIVE 1" SERVICE | | | (LOCATION: SIDEWALK 4' WEST OF OKEECHOBEE DRIVEWAY) | | | COULD BE ACTIVATED AND DESIGNATED AS IRRIGATION. WITH | | | CURRENT CONFIGURATION DOMESTIC WATER USED FOR | | | IRRIGATION WILL BE CHARGED SEWAGE AGAINST IT. | | | | | | #5 ACCESS DRIVE EXITING TO 20FT WIDE ALLEY MUST BE AS | | | PER CITY OF WEST PALM BEACH STANDARD DRIVEWAY APRON. | | | 20FT WIDE IS THE MAX + 3' FOOT FLARE + 3' CURB | | | TRANSITION. APRON MUST BE 6" THICK CONCRETE AND 3000PSI | | | MINIMUM. REFER TO: | | | HTTP://WWW.WPB.ORG/ENGINEERING/PDF/STANDARDS/GC-6.PDF | | | | | | #6 IT IS HIGHLY SUGGESTIVE THAT CHAIN LINK FENCE | | | SURROUNDING REAR LOT, BE PLACED AROUND DRY DETENTION | | | AREAS. THIS WOULD ALLOW PROTECTION FOR PEDESTRIANS WHO | | | COULD INADVERTENTLY WALK INTO THE SITE AND FALL. | | | | | | PLEASE FEEL FREE TO DIRECT ANY SPECIFIC QUESTION SHOULD | | | YOU NEED CLARIFICATION ON ANY OF THE ABOVE MENTIONED | | | ITEMS. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2011-10-28 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2011-10-28 |
Time |
14:46 |
Rev Time |
0.25 |
| Received By |
mgonzale |
Date |
2011-10-28 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2011-10-28 15:14:50 | PASSED WITH PROVISOS - PLAN IS ACCEPTABLE FOR BUILDING | | | RENOVATIONS. | | | PLEASE SUPPLY SITE PERVIOUS AND IMPERVIOUS INFORMATION | | | TO: | | | THIS INFORMATION WILL BE UTILIZED TO UPDATE CITY'S | | | STORMWATER ACCOUNT. | | | | | | BRIAN R MOREE | | | ENGINEERING SERVICES CONSTRUCTION SUPERVISOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33401 | | | PHONE: 494-1040 EXT: 1098 | | | FAX: 494-1118 | | | E-MAIL: [email protected] | | | SERVING SINCE NOV 12, 2000 | | | EMPLOYMENT CATEGORY: FR | | | | | | ************************************************ | | | | | | MANUEL JULIAN GONZALEZ | | | CSD ENGINEERING SERVICES | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2011-09-07 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2011-09-07 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
mgonzale |
Date |
2011-09-07 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2011-09-07 09:47:14 | FAILED: | | | | | | #1 PLEASE ADDRESS COMMENTS IN WRITING ISSUED DURING | | | PPRC. | | | | | | MANUEL JULIAN GONZALEZ | | | CSD ENGINEERING REVIEW | | | 401 CLEMATIS STREET, | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2012-03-05 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-03-05 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-03-05 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2012-03-05 12:58:04 | 2301 OKEECHOBEE BOULEVARD - BUILDING 1, 2 & 3 | | | PERMIT #11070617 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SHEET A1.1 | | | PARTS #2109 - OPEN GRATE AREA: STORAGE TO BE MAINTAINED | | | AT OR BELOW 12'-0" TOTAL HEIGHT. PAINT STRIPE AROUND | | | ROOM TO MARK ELEVATION OF MAXIMUM STORAGE, OTHERWISE | | | FIRE SPRINKLERS ARE REQUIRED FOR HIGH-PILED STORAGE. | | | SOLID FLOOR AREA: PROVIDE PERMANENT SIGNAGE READING | | | STORAGE TO BE MAINTAINED 24" BELOW STRUCTURE. | | | | | | SHEET 1-A2.0 | | | PROVIDE MINIMUM CEILING HEIGHT OF 7'-6". SURFACE | | | MOUNTED LIGHTING MAY IMPEDE UPON THIS HEADROOM. | | | | | | SHEET 3-A5.0 | | | INDICATE WHAT MATERIALS AND QUANTITIES OF MATERIALS | | | WILL BE STORED IN DETAIL STORAGE #1311. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2012-02-07 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-02-07 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-01-31 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2012-02-07 10:58:26 | 2301 OKEECHOBEE BOULEVARD - BUILDING 1, 2 & 3 | | | PERMIT #11070617 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SHEET 1-A1.0 | | | PARTS #1128 - MEZZANINE STAIRS SHALL BE 36" WIDE | | | MINIMUM. | | | | | | PROVIDE FIRE RATED SEPARATION BETWEEN PARTS (STORAGE) | | | AND BUSINESS OCCUPANCY. PROTECT ALL OPENINGS AND | | | PENETRATIONS. | | | NOTE: THE RATED WALLS AND DOORS DO NOT AGREE BETWEEN | | | PLAN SHEETS 1-A1.0 AND 1-A3.0. | | | | | | SHEET A1.1 | | | PARTS #2109 - THE MEZZANINE MAY BE REQUIRED TO BE | | | LIMITED TO 1/3 OR 1/2 THE AREA OF THE FLOOR BELOW. | | | | | | SHEET 1-A2.0 | | | PROVIDE MINIMUM CEILING HEIGHT OF 7'-6". NEED VENDOR | | | SHELVING LAYOUT TO COMPARE TO SURFACE MOUNTED CEILING | | | LIGHT LOCATIONS. | | | | | | NEED AN ADDITIONAL EXIT SIGN TO LEAD TO SECONDARY EXIT | | | IN PARTS #1128. | | | | | | CUSTOMER WAITING #1117 HAS EXIT SIGNS ROUTING OCCUPANTS | | | TO A MORE HAZARDOUS OCCUPANCY. | | | | | | SHEET 1-A3.0 | | | RELOCATE TABLES AND CHAIRS (NEAR TWO SOUTH DOUBLE EXIT | | | DOORS) TO KEEP DIRECT UNOBSTRUCTED PATH TO EXITS. | | | | | | PROVIDE EXIT SIGN FOR PARTS STORAGE EAST EXIT AND MINOR | | | REPAIRS AREA NORTH EXIT. | | | NOTE: THE RCP EXIT SIGN LOCATIONS DO NOT MATCH ON | | | SHEETS 1-A2.0 AND 1-A3.0. | | | | | | SHEET 1-A3.1 | | | THE MAXIMUM OCCUPANT LOAD FOR THE BUSINESS MEZZANINE | | | NEEDS TO BE SHOWN AS 10 PERSONS, OTHERWISE AN | | | ADDITIONAL EXIT IS REQUIRED. | | | | | | SHEET 3-A5.0 | | | INDICATE WHAT MATERIALS AND QUANTITIES OF MATERIALS | | | WILL BE STORED IN DETAIL STORAGE #1311. | | | | | | GENERAL | | | PROVIDE GUARD RAIL FOR PARTS MEZZANINE. | | | | | | STORAGE NEEDS TO BE MAINTAINED AT 24" BELOW THE CEILING | | | OR STRUCTURE IN THE PARTS MEZZANINE. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-10-13 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-10-13 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-10-13 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2011-10-13 14:55:18 | 2301 OKEECHOBEE BOULEVARD - BUILDING 1, 2 & 3 | | | PERMIT #11070617 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PROVIDE A DETAILED SITE PLAN INDICATING FIRE DEPARTMENT | | | VEHICLE ACCESS WIDTHS, MARKED FIRE LANES, FIRE HYDRANT | | | LOCATIONS, PERIMETER GATES/FENCES, CONSTRUCTION | | | TRAILERS ETC. | | | | | | BUILDING #2: IF POSSIBLE, RELOCATE KNOXBOX AND FIRE | | | ALARM ANUNCIATOR PANEL NEAR AN EAST ENTRY DOOR AS THIS | | | WILL BE THE ACCESS SIDE FOR EMERGENCY RESPONDERS. THE | | | WEST SIDE OF THE BUILDING ABUTTS THE FENCE AND PROPERTY | | | LINE. | | | | | | PER LOCAL CODE AMENDMENTS, DUCT SMOKE DETECTORS SHALL | | | INITIATE A GENERAL FIRE ALARM CONDITION. | | | | | | DRAWINGS WILL BE STAMPED, INITIALED, AND DATED BY THE | | | FIRE DEPARTMENT AFTER ALL OTHER PLAN REVIEWER COMMENTS | | | HAVE BEEN SATISFIED. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-08-08 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-08-08 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-08-08 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2011-08-08 12:25:20 | 2301 OKEECHOBEE BOULEVARD - BUILDING 1, 2 & 3 | | | PERMIT #11070617 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | DESIGN SHALL CONFORM TO THE 2007 EDITION OF THE FLORIDA | | | FIRE PREVENTION CODE WHICH CONTAINS THE FLORIDA EDITION | | | OF NFPA 1 AND NFPA 101. | | | | | | PROVIDE A DETAILED SITE PLAN INDICATING FIRE DEPARTMENT | | | VEHICLE ACCESS WIDTHS, MARKED FIRE LANES, FIRE HYDRANT | | | LOCATIONS, PERIMETER GATES/FENCES, CONSTRUCTION | | | TRAILERS ETC. | | | | | | ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS | | | OF NFPA 241. TRASH AND DEBRIS TO BE REMOVED FROM THE | | | SITE DAILY. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF | | | THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDINGS DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | PROVIDE BUILDING NUMBER AND BUILDING ADDRESS VISIBLE | | | FROM THE STREET. NUMBERS SHALL BE AT LEAST SIX-INCHES | | | IN HEIGHT AND SHALL CONTRAST THE BACKGROUND (REFERENCE: | | | SECTION 10.12.1.2 OF THE FLORIDA FIRE PREVENTION CODE - | | | NFPA 1). | | | | | | PROVIDE A LIFE SAFETY PLAN CLEARLY INDICATING FIRE | | | RATED WALLS, FIRE RATED DOORS, OCCUPANT LOADS, EXIT | | | SIGNS, EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON | | | PATH OF TRAVEL, FIRE EXTINGUISHERS ETC. | | | | | | THE BUILDING IS FUNCTIONING AS A MULTIUSE OCCUPANCY. | | | INDICATE IF THE BUILDING IS DESIGNED FOR MIXED USE | | | (NON-SEPARATED) OR SEPARATED USE PER SECTION 6.1.14.2.1 | | | OF NFPA 101 FLORIDA EDITION 2006. THE ONLY FIRE RATED | | | SEPARATION APPEARS TO BE THE 2-HOUR FIRE BARRIER | | | SEPARATING THE INTERIOR SERVICE BAYS FROM THE ADJACENT | | | INTERIOR SPACE. | | | | | | THE SERVICE AREAS APPEAR TO BE FUNCTIONING MORE LIKE AN | | | INDUSTRIAL/FACTORY OCCUPANCY THAN A STORAGE OCCUPANCY. | | | | | | INDICATE IF THE SERVICE AREAS AND BODY SHOP AREAS WILL | | | BE FUNCTIONING AS A MAJOR OR MINOR REPAIR GARAGE AS PER | | | SECTION 3.3.165.21.1 OF NFPA 1. | | | | | | NO SMOKING OR OPEN FLAME SIGNS TO BE POSTED IN ALL | | | SERVICE AREAS, BODY SHOPS AND PAINT BOOTH AREAS. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | | | THE BUSINESS OFFICES (#2101, #2104 ETC.) ARE INDICATED | | | AS BEING LOCATED ON THE MEZZANINE; HOWEVER, THIS SPACE | | | DOES NOT MEET THE DEFINITION OF A MEZZANINE (SECTION | | | 8.6.9 NFPA 101) WHEREBY THE MEZZANINE SPACE IS OPEN TO | | | THE FLOOR BELOW UNLESS THE OCCUPANT LOAD OF THE | | | AGGREGATE AREA OF THE ENCLOSED SPACE DOES NOT EXCEED | | | 10. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | HANDRAILS ARE REQUIRED TO BE INSTALLED ON BOTH SIDES OF | | | STAIRS. | | | | | | SPRAYING OF FLAMMABLE LIQUIDS (PAINT) SHALL CONFORM TO | | | THE REQUIMENTS OF NFPA 33. | | | | | | STORAGE AND HANDLING OF FLAMMABLE LIQUIDS SHALL CONFORM | | | TO THE REQUIREMENTS OF NFPA 30. | | | | | | INDICATE THE QUANTITIES OF FLAMMABLE LIQUIDS TO BE | | | HOUSED IN THE PAINT SHOP AND MIXING ROOM. | | | | | | PAINT SHOP #1304 TO BE PROVIDED WITH TWO EXITS WHEREBY | | | ONE FIRE EVENT WILL NOT RESTRICT ACCESS TO BOTH EXITS. | | | | | | INDICATE THE AREAS THAT WILL BE PROTECTED BY A FIRE | | | SUPPRESSION SYSTEM(S). | | | | | | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR | | | INSTALLATION OF FIRE SPRINKLERS, FIRE ALARMS, PAINT | | | SPRAY BOOTHS AND ANY OTHER SPECIALTY TRADE. | | | | | | SHEET FA0.1 BOTH FIRE ALARM RISER DIAGRAMS INDICATED AS | | | BUILDING #1. | | | | | | SHEET 1FA2.2 NOT SEALED BY ENGINEER. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2012-03-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2012-03-23 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-02-27 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-03-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2012-02-07 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-01-19 |
Time |
17:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-11-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-11-03 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-09-22 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2011-09-23 16:18:19 | C--27 & 28 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-09-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-09-07 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-07-27 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2012-03-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-03-09 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-03-09 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2012-02-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-02-08 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-02-07 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2012-02-08 13:02:17 | PLANS DENIED | | | 1) REFER TO SECTION 607.5.1 FIRE WALLS 2007 FBC (M) | | | MISSING FIRE DAMPERS PAGE 1-M2.1 AND 1-M2.2. | | | OF THE PLANS. | | | 2) PLEASE INDICATE ON THE PLANS WHERE THE 21X14 | | | DUCT IS GOING AND TO WHAT UNIT PAGE 1-M2.1 | | | 3) PLEASE INDICATE RATED WALLS ON THE MECHANICAL PLANS | | | 4) PROVIDE A PIPING ISOMETRIC ON MECHANICAL PLANS FOR | | | THE AIR COMPRESSOR, MO LINES WO LINES AND ATF LINES. | | | 5) THERE IS NO SUPPLY AIR IN ROOMS 1141 THROUGH 1145 ON | | | PAGE 1-M2.1 PLEASE EXPLAIN. | | | 6) INDICATE WHAT UNIT IS COOLING CAR RENTAL AREA ON | | | PAGE 3-M2.1 | | | 7) PROVIDE PRODUCT APPROVALS FOR OUT DOOR LOUVERS PER | | | SECTION | | | 106.33 2007 FBC. | | | 8) PROVIDE EXHAUST FAN NUMBERS ON EXHAUST AIR | | | CALCULATIONS. | | | 9) PROVIDE A DETAIL ON CONDENSER STAND AND CURB TO ROOF | | | TIE DOWN PER SECTION 301.12 WIND RESISTANCE 2007 FBC | | | (M) | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-11-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-11-03 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-11-02 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-08-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-08-30 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-08-24 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2011-08-30 13:19:34 | PLANS DENIED | | | PLEASE MARK THE RTU EQUIPMENT ON THE DUCT PLANS PAGE M | | | 2.1. | | | SECTION 301.12 WIND RESISTANCE 2007 FBC (M) . THE USE | | | OF WOOD SLEEPERS SHALL | | | NOT BE PERMITTED . ROOF PIPING SUPPORT DETAIL PAGE M7.1 | | | PLAIN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2012-03-02 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-03-02 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-03-01 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2012-02-03 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-02-03 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-01-30 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2012-02-03 12:45:07 | FBC PLUMBING 2007 REVIEW #1 | | | | | | ***NOTE*** | | | SHEET 1A-1.0 SHOWS THREE EYE WASH STATIONS. IF THEY ARE | | | NOT SELF CONTAINED PLEASE SHOW WATER PIPE ON PLUMBING | | | DRAWINGS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-10-07 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-10-07 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-10-07 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-08-15 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-08-15 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-08-04 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2011-08-15 14:28:34 | FBC PLUMBING 2007 REVIEW #1 | | | DENIED: | | | | | | 1. SHEET P0.1 DETAIL SHOWS A SCHLER SIT-150-C OIL | | | SEPARATOR DETAIL. SHEETS 1P-2.1 & 2P-2.1 CALL FOR A | | | SEPARATOR WITH NO COLLECTION TANK. | | | | | | 2. SHEET P7.2 THE SECTION OF PIPE LABELED 6,032 SHOULD | | | BE 8" . THE SECTION OF PIPE LABELED 9,880 SHOULD BE 10" | | | PIPE BASED ON 1/8" PER FOOT & 5" RAINFALL. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2012-03-23 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-03-23 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-03-23 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2012-03-23 14:27:45 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 03.23.2012 | | | PERMIT NO.: 11070617 AND 11070619 | | | ADDRESS: 2301 AND 2321 OKEECHOBEE BOULEVARD | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: RENOVATION TO EXISTING STRUCTURES/SITE | | | FOR REESTABLISHMENT OF A CAR DEALERSHIP. | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY: | | | | | | A. A REVISED TRAFFIC CONCURRENCY LETTER SHALL BE | | | PROVIDED FROM THE PALM BEACH COUNTY DEPARTMENT OF | | | ENGINEERING AND PUBLIC WORKS ? TRAFFIC ENGINEERING | | | DIVISION INDICATING THEIR REVIEW AND APPROVAL OF THE | | | REVISED BUILDING SQUARE FOOTAGE. | | | | | | B. THE ENTIRE SITE SHALL BE BROUGHT INTO COMPLIANCE | | | WITH ARTICLE XIV (LANDSCAPING) OF THE CITY'S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS) AS THE VALUE OF | | | THE WORK EXCEEDS 50 PERCENT OF THE VALUE OF THE | | | STRUCTURE [THESE REQUIRED IMPROVEMENTS ARE REFLECTED IN | | | THE CPD APPLICATION THAT IS IN PROCESS, AND REFERENCED | | | ABOVE]. ALL APPLICABLE PLANS (I.E. SITE PLANS, | | | LANDSCAPE PLANS, ETC) WILL NEED TO BE SUBMITTED UNDER | | | SEPARATE PERMITS. PLEASE ENSURE THAT ALL PLANS MATCH | | | THOSE THAT ARE A PART OF THE CPD. UPON SUBMITTAL OF | | | PERMIT APPLICATIONS FOR THE SITE WORK, LANDSCAPING, | | | ETC. PLEASE ENSURE THAT DETAILS ARE PROVIDED FOR ALL | | | IMPROVEMENTS SUCH AS GATES, FENCES, DUMPSTER | | | ENCLOSURES, PARKING STRIPING, ETC. | | | | | | C. BUILDING #3: - THE ROOF TOP MECHANICAL EQUIPMENT | | | SHALL BE SCREENED FROM VIEW. UPON INSTALLATION OF THE | | | EQUIPMENT, AND PRIOR TO FINAL INSPECTION, A SITE VISIT | | | SHALL COORDINATE WITH THE PLANNING DIVISION. IF IT IS | | | DETERMINED THAT THE MECHANICAL EQUIPMENT IS VISIBLE, | | | APPROPRIATE SCREENING SHALL BE ADDED. | | | | | | 2. ALL SITE LIGHTING SHALL BE SUBMITTED UNDER A | | | SEPARATE PERMIT. | | | | | | A. A PHOTOMETRIC PLAN SHALL BE SUBMITTED TO THE CITY?S | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | INDICATING THAT ANY NEW SITE LIGHTING, OR UPGRADES TO | | | EXISTING SITE LIGHTING, DO NOT EXCEED 1.0 FOOTCANDLES | | | WHEN MEASURED AT THE BOUNDARY OF THE DEVELOPMENT. | | | | | | B. THE ELECTRICAL SITE PLAN DOES NOT MATCH THE SITE | | | PLAN THAT IS PROPOSED AND RESULTS IN SEVERAL CONFLICTS | | | BETWEEN LIGHTING LOCATION, PARKING, TREE INSTALLATION, | | | ETC. PLEASE ENSURE THAT ALL PLANS ARE CONSISTENT. | | | | | | C. DETAILS NEED TO BE PROVIDED REGARDING PROPOSED LIGHT | | | POLES, INCLUDING OVERALL HEIGHT. | | | | | | 3. PLEASE NOTE THAT ALL SIGNAGE WILL NEED TO CONFORM TO | | | THE REQUIREMENTS OF THE GENERAL COMMERCIAL (GC) ZONING | | | DISTRICT AND WILL BE REVIEWED UPON SUBMITTAL....THIS | | | WILL NOT HOLD UP ISSUANCE OF A PERMIT, BUT IS JUST A | | | REMINDER WHEN CONSIDERING SIGNAGE FOR THE DEVELOPMENT | | | AND SUBMITTAL OF SIGN PERMITS. PLEASE NOTE THAT WALL | | | SIGNS ARE LIMITED TO ONE (1) SIGN PER BUSINESS, PLUS | | | TWO (2) ADDITIONAL SIGNS, RESULTING IN ONLY THREE (3) | | | TOTAL SIGNS PERMITTED FOR THE PROJECT. | | | | | | 4. THE FENCING SURROUNDING THE OIL STORAGE PEN SHALL BE | | | SOLID/OPAQUE, NOT CHAIN LINK. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2012-03-12 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-03-12 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-03-12 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2012-03-12 10:51:56 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 03.12.2012 | | | PERMIT NO.: 11070617 AND 11070619 | | | ADDRESS: 2301 OKEECHOBEE BOULEVARD | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. AN APPLICATION FOR A UNITY OF TITLE SHALL BE | | | SUBMITTED TO THE CITY?S ENGINEERING SERVICES | | | DEPARTMENT. UPON APPROVAL OF THE APPLICATION, THE UNITY | | | OF TITLE SHALL BE RECORDED IN THE PUBLIC RECORDS OF | | | PALM BEACH COUNTY, AND A CERTIFIED COPY SHALL BE | | | SUBMITTED TO THE CITY?S DEVELOPMENT SERVICES DEPARTMENT | | | ? PLANNING DIVISION. | | | | | | 2. A REVISED TRAFFIC CONCURRENCY LETTER SHALL BE | | | PROVIDED FROM THE PALM BEACH COUNTY DEPARTMENT OF | | | ENGINEERING AND PUBLIC WORKS ? TRAFFIC ENGINEERING | | | DIVISION INDICATING THEIR REVIEW AND APPROVAL OF THE | | | REVISED BUILDING SQUARE FOOTAGE. | | | | | | 3. A PHOTOMETRIC PLAN SHALL BE SUBMITTED TO THE CITY?S | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | INDICATING THAT ANY NEW SITE LIGHTING, OR UPGRADES TO | | | EXISTING SITE LIGHTING, DO NOT EXCEED 1.0 FOOTCANDLES | | | WHEN MEASURED AT THE BOUNDARY OF THE DEVELOPMENT. | | | | | | 4. A CONSTRUCTION SITE SECURITY AND MANAGEMENT PLAN | | | SHALL BE SUBMITTED TO, AND APPROVED BY, THE CITY OF | | | WEST PALM BEACH POLICE DEPARTMENT ? CRIME PREVENTION | | | UNIT. | | | | | | 5. THE ENTIRE SITE SHALL BE BROUGHT INTO COMPLIANCE | | | WITH ARTICLE XIV (LANDSCAPING) OF THE CITY'S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS) AS THE VALUE OF | | | THE WORK EXCEEDS 50 PERCENT OF THE VALUE OF THE | | | STRUCTURE [THESE REQUIRED IMPROVEMENTS ARE REFLECTED IN | | | THE CPD APPLICATION THAT IS IN PROCESS, AND REFERENCED | | | ABOVE]. ALL APPLICABLE PLANS (I.E. SITE PLANS, | | | LANDSCAPE PLANS, ETC) WILL NEED TO BE SUBMITTED UNDER | | | SEPARATE PERMITS. PLEASE ENSURE THAT ALL PLANS MATCH | | | THOSE THAT ARE A PART OF THE CPD. UPON SUBMITTAL OF | | | PERMIT APPLICATIONS FOR THE SITE WORK, LANDSCAPING, | | | ETC. PLEASE ENSURE THAT DETAILS ARE PROVIDED FOR ALL | | | IMPROVEMENTS SUCH AS GATES, FENCES, DUMPSTER | | | ENCLOSURES, PARKING STRIPING, ETC. | | | | | | 6. PLEASE ENSURE THAT ALL FLOOR PLANS, ELEVATIONS, ETC. | | | ARE CONSISTENT WITH THE PROPOSED SITE PLAN | | | MODIFICATIONS. | | | | | | 7. PLEASE NOTE THAT ALL SIGNAGE WILL NEED TO CONFORM TO | | | THE REQUIREMENTS OF THE GENERAL COMMERCIAL (GC) ZONING | | | DISTRICT AND WILL BE REVIEWED UPON SUBMITTAL....THIS | | | WILL NOT HOLD UP ISSUANCE OF A PERMIT, BUT IS JUST A | | | REMINDER WHEN CONSIDERING SIGNAGE FOR THE DEVELOPMENT | | | AND SUBMITTAL OF SIGN PERMITS. PLEASE NOTE THAT WALL | | | SIGNS ARE LIMITED TO ONE (1) SIGN PER BUSINESS, PLUS | | | TWO (2) ADDITIONAL SIGNS, RESULTING IN ONLY THREE (3) | | | TOTAL SIGNS PERMITTED FOR THE PROJECT. | | | | | | 8. THE ELECTRICAL SITE PLAN DOES NOT MATCH THE SITE | | | PLAN THAT IS PROPOSED AND RESULTS IN SEVERAL CONFLICTS | | | BETWEEN LIGHTING LOCATION, PARKING, TREE INSTALLATION, | | | ETC. PLEASE ENSURE THAT ALL PLANS ARE CONSISTENT. | | | | | | 9. DETAILS NEED TO BE PROVIDED REGARDING PROPOSED LIGHT | | | POLES, INCLUDING OVERALL HEIGHT. | | | | | | 10. PLEASE NOTE THAT PARKING SPACES ADJACENT TO | | | REQUIRED LANDSCAPE BUFFERS WILL NEED TO HAVE WHEEL | | | STOPS (OR THE CURB LINE MOVED IN) TO KEEP VEHICLES FROM | | | OVERHANGING INTO THE REQUIRED LANDSCAPE AREA. THE SITE | | | PLAN PROPOSED AS PART OF THE CPD APPLICATION ADDRESSES | | | THIS COMMENT. | | | | | | 11. THE FENCING SURROUNDING THE OIL STORAGE PEN SHALL | | | BE SOLID/OPAQUE, NOT CHAIN LINK. | | | | | | 12. BUILDING #1: | | | | | | A. THE STAIRS ON THE SOUTH SIDE OF BUILDING #1 ARE | | | INCONSISTENT WITH THE PROPOSED SITE PLAN AND ENCROACH | | | INTO THE PROPOSED PARKING SPACES. | | | | | | 13. BUILDING #3: | | | | | | A. PLEASE PROVIDE INFORMATION REGARDING THE ROOF-TOP | | | MECHANICAL EQUIPMENT ON TOP OF BUILDING #3. IT APPEARS | | | THAT THERE IS NO PARAPET, AND THE MECHANICAL EQUIPMENT | | | SHALL BE SCREENED FROM VIEW. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2012-02-10 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2012-02-10 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2012-02-07 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2012-02-10 10:46:06 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.10.2012 | | | PERMIT NO.: 11070617 AND 11070619 | | | ADDRESS: 2301 OKEECHOBEE BOULEVARD, #1 & #3 | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: RENOVATIONS TO EXISTING CAR SALES | | | FACILITY. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | GENERAL COMMENTS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE | | | COMMERCIAL PLANNED DEVELOPMENT (CPD) APPLICATION | | | SUBMITTED TO THE CITY'S PLANNING AND ZONING DEPARTMENT | | | SHALL BE APPROVED BY THE CITY COMMISSION. | | | | | | 2. THE ENTIRE SITE SHALL BE BROUGHT INTO COMPLIANCE | | | WITH ARTICLE XIV (LANDSCAPING) OF THE CITY'S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS) AS THE VALUE OF | | | THE WORK EXCEEDS 50 PERCENT OF THE VALUE OF THE | | | STRUCTURE [THESE REQUIRED IMPROVEMENTS ARE REFLECTED IN | | | THE CPD APPLICATION THAT IS IN PROCESS, AND REFERENCED | | | ABOVE]. ALL APPLICABLE PLANS (I.E. SITE PLANS, | | | LANDSCAPE PLANS, ETC) WILL NEED TO BE SUBMITTED UNDER | | | SEPARATE PERMITS. PLEASE NOTE THAT THE SITE PLAN | | | SUBMITTED AS PART OF THIS PERMIT APPLICATION DOES NOT | | | CORRESPOND WITH THE SITE PLAN THAT IS PROPOSED AS PART | | | OF THE CPD APPLICATION. PLEASE ENSURE THAT ALL PLANS | | | MATCH THOSE THAT ARE A PART OF THE CPD. UPON SUBMITTAL | | | OF PERMIT APPLICATIONS FOR THE SITE WORK, LANDSCAPING, | | | ETC. PLEASE ENSURE THAT DETAILS ARE PROVIDED FOR ALL | | | IMPROVEMENTS SUCH AS GATES, FENCES, DUMPSTER | | | ENCLOSURES, PARKING STRIPING, ETC. | | | | | | 3. PLEASE ENSURE THAT ALL FLOOR PLANS, ELEVATIONS, ETC. | | | ARE CONSISTENT WITH THE PROPOSED SITE PLAN | | | MODIFICATIONS. | | | | | | 4. PLEASE NOTE THAT ALL SIGNAGE WILL NEED TO CONFORM TO | | | THE REQUIREMENTS OF THE GENERAL COMMERCIAL (GC) ZONING | | | DISTRICT AND WILL BE REVIEWED UPON SUBMITTAL....THIS | | | WILL NOT HOLD UP ISSUANCE OF A PERMIT, BUT IS JUST A | | | REMINDER WHEN CONSIDERING SIGNAGE FOR THE DEVELOPMENT | | | AND SUBMITTAL OF SIGN PERMITS. PLEASE NOTE THAT WALL | | | SIGNS ARE LIMITED TO ONE (1) SIGN PER BUSINESS, PLUS | | | TWO (2) ADDITIONAL SIGNS?RESULTING IN ONLY THREE (3) | | | TOTAL SIGNS PERMITTED FOR THE PROJECT. | | | | | | 5. THE ELECTRICAL SITE PLAN DOES NOT MATCH THE SITE | | | PLAN THAT IS PROPOSED AND RESULTS IN SEVERAL CONFLICTS | | | BETWEEN LIGHTING LOCATION, PARKING, TREE INSTALLATION, | | | ETC. PLEASE ENSURE THAT ALL PLANS ARE CONSISTENT. | | | | | | 6. A PHOTOMETRIC PLAN SHALL BE PROVIDED INDICATING | | | NUMBER OF FOOTCANDLES AS MEASURED AT THE PROPERTY | | | LINES. LIGHTING SHALL NOT EXCEED 1.0 FOOTCANDLES AT THE | | | PROPERTY LINE. | | | | | | 7. DETAILS NEED TO BE PROVIDED REGARDING PROPOSED LIGHT | | | POLES, INCLUDING OVERALL HEIGHT. | | | | | | 8. PLEASE NOTE THAT PARKING SPACES ADJACENT TO REQUIRED | | | LANDSCAPE BUFFERS WILL NEED TO HAVE WHEEL STOPS (OR THE | | | CURB LINE MOVED IN) TO KEEP VEHICLES FROM OVERHANGING | | | INTO THE REQUIRED LANDSCAPE AREA. THE SITE PLAN | | | PROPOSED AS PART OF THE CPD APPLICATION ADDRESSES THIS | | | COMMENT. | | | | | | 9. THE FENCING SURROUNDING THE OIL STORAGE PEN SHALL BE | | | SOLID/OPAQUE, NOT CHAIN LINK. | | | | | | BUILDING #1: | | | | | | 1. THE STAIRS ON THE SOUTH SIDE OF BUILDING #1 ARE | | | INCONSISTENT WITH THE PROPOSED SITE PLAN AND ENCROACH | | | INTO THE PROPOSED PARKING SPACES. | | | | | | BUILDING #3: | | | | | | 1. PLEASE PROVIDE INFORMATION REGARDING THE ROOF-TOP | | | MECHANICAL EQUIPMENT ON TOP OF BUILDING #3. IT APPEARS | | | THAT THERE IS NO PARAPET?AND THE MECHANICAL EQUIPMENT | | | SHALL BE SCREENED FROM VIEW. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | PLANNING AND ZONING DEPARTMENT | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2011-10-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2011-10-06 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2011-10-06 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2011-10-06 14:59:23 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 10.06.2011 | | | PERMIT NO.: 11070617, 11070618, AND 11070619 | | | ADDRESS: 2301 OKEECHOBEE BOULEVARD, #1-3 | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: RENOVATIONS TO EXISTING CAR SALES | | | FACILITY. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | GENERAL COMMENTS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE | | | COMMERCIAL PLANNED DEVELOPMENT (CPD) APPLICATION | | | SUBMITTED TO THE CITY'S PLANNING AND ZONING DEPARTMENT | | | SHALL BE APPROVED BY THE CITY COMMISSION. | | | | | | 2. THE ENTIRE SITE SHALL BE BROUGHT INTO COMPLIANCE | | | WITH ARTICLE XIV (LANDSCAPING) OF THE CITY'S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS) AS THE VALUE OF | | | THE WORK EXCEEDS 50 PERCENT OF THE VALUE OF THE | | | STRUCTURE [THESE REQUIRED IMPROVEMENTS ARE REFLECTED IN | | | THE CPD APPLICATION THAT IS IN PROCESS, AND REFERENCED | | | ABOVE]. ALL APPLICABLE PLANS (I.E. SITE PLANS, | | | LANDSCAPE PLANS, ETC) WILL NEED TO BE SUBMITTED UNDER | | | SEPARATE PERMITS. | | | | | | 3. PLEASE ENSURE THAT ALL FLOOR PLANS, ELEVATIONS, ETC. | | | ARE CONSISTENT WITH THE PROPOSED SITE PLAN | | | MODIFICATIONS. SEE MORE SPECIFIC COMMENTS BELOW. | | | | | | 4. PLEASE NOTE THAT ALL SIGNAGE WILL NEED TO CONFORM TO | | | THE REQUIREMENTS OF THE GENERAL COMMERCIAL (GC) ZONING | | | DISTRICT AND WILL BE REVIEWED UPON SUBMITTAL....THIS | | | WILL NOT HOLD UP ISSUANCE OF A PERMIT, BUT IS JUST A | | | REMINDER WHEN CONSIDERING SIGNAGE FOR THE DEVELOPMENT | | | AND SUBMITTAL OF SIGN PERMITS. | | | | | | 5. THE ELECTRICAL SITE PLAN DOES NOT MATCH THE SITE | | | PLAN THAT IS PROPOSED. | | | | | | 6. THERE ARE SEVERAL LOCATIONS WHERE EXISTING LIGHT | | | POLES CONFLICT WITH THE PROPOSED SITE PLAN. A) THERE IS | | | A POLE TO THE NORTH OF BUILDING #3 THAT APPEARS THAT IT | | | MAY BE LOCATED IN THE PARKING LOT DRIVE AISLE. PLEASE | | | CONFIRM THAT IT WILL BE OUTSIDE OF THE MINIMUM 24 CLEAR | | | WIDTH REQUIREMENT. B) THERE IS A POLE BETWEEN BUILDINGS | | | #2 AND #3...THIS SPACE WILL NEED TO BE STRIPED AS "NO | | | PARKING" OR THE POLE WILL NEED TO BE RELOCATED. C) | | | THERE IS A POLE TO THE NORTH OF BUILDING #1...IT IS | | | PREFERRED THAT THIS POLE BE RELOCATED, BUT AS LONG AS | | | THIS IS MAINTAINED AS INVENTORY PARKING ONLY, IT MAY BE | | | ABLE TO REMAIN. D) THERE IS ONE POLE SOUTH OF BUILDING | | | #2 THAT IS LOCATED IN THE DRIVE AISLE.....THE CURB FOR | | | THE LANDSCAPE ISLAND COULD BE EXTENDED OUT TO ENCOMPASS | | | THIS POLE, SO LONG AS 20 MINIMUM WIDTH IS MAINTAINED | | | BETWEEN THE ISLAND AND THE CURB TO THE WEST. E) THERE | | | ARE 3 POLES AT THE HEAD OF PARKING SPACES SOUTH OF | | | BUILDING #2...THESE WILL NEED TO BE STRIPED AS | | | "COMPACT" SPACES AND THE WHEEL STOPS ADJUSTED TO | | | PROVIDE THE 2-FOOT CLEAR OVERHANG. | | | | | | 7. PLEASE NOTE THAT PARKING SPACES ADJACENT TO REQUIRED | | | LANDSCAPE BUFFERS WILL NEED TO HAVE WHEEL STOPS (OR THE | | | CURB LINE MOVED IN) TO KEEP VEHICLES FROM OVERHANGING | | | INTO THE REQUIRED LANDSCAPE AREA. | | | | | | BUILDING #1: | | | | | | 1. THE WESTERN-MOST STAIR ON THE SOUTH SIDE OF BUILDING | | | #1 IS INCONSISTENT WITH THE PROPOSED SITE PLAN AND | | | ENCROACHES INTO THE PROPOSED PARKING SPACES. | | | | | | BUILDING #2: | | | | | | 1. THE STAIRWAYS AND HANDICAP RAMP ON THE SOUTH SIDE OF | | | THE BUILDING APPEAR TO CONFLICT WITH THE PROPOSED | | | PARKING LAYOUT....THE HC RAMP AND STAIRS WOULD ENCROACH | | | INTO THE PROPOSED PARKING. | | | | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | PLANNING AND ZONING DEPARTMENT | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-08-14 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2011-08-14 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2011-08-14 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2011-08-14 14:11:16 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 08.14.2011 | | | PERMIT NO.: 11070617, 11070618, AND 11070619 | | | ADDRESS: 2301 OKEECHOBEE BOULEVARD, #1-3 | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: RENOVATIONS TO EXISTING CAR SALES | | | FACILITY. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | GENERAL COMMENTS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE | | | COMMERCIAL PLANNED DEVELOPMENT (CPD) APPLICATION | | | SUBMITTED TO THE CITY?S PLANNING AND ZONING DEPARTMENT | | | SHALL BE APPROVED BY THE CITY COMMISSION. | | | | | | 2. THE ENTIRE SITE SHALL BE BROUGHT INTO COMPLIANCE | | | WITH ARTICLE XIV (LANDSCAPING) OF THE CITY?S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS) AS THE VALUE OF | | | THE WORK EXCEEDS 50 PERCENT OF THE VALUE OF THE | | | STRUCTURE [THESE REQUIRED IMPROVEMENTS ARE REFLECTED IN | | | THE CPD APPLICATION THAT IS IN PROCESS, AND REFERENCED | | | ABOVE]. ALL APPLICABLE PLANS (I.E. SITE PLANS, | | | LANDSCAPE PLANS, ETC) WILL NEED TO BE SUBMITTED. | | | | | | 3. PLEASE ENSURE THAT ALL FLOOR PLANS, ELEVATIONS, ETC. | | | ARE CONSISTENT WITH THE PROPOSED SITE PLAN | | | MODIFICATIONS. | | | | | | 4. THE TOTAL SQUARE FOOTAGES SHOWN ON THE COVER SHEET | | | DO NOT MATCH THOSE THAT WERE SUBMITTED AS PART OF THE | | | CPD APPLICATION REFERENCED ABOVE. PLEASE ENSURE THAT | | | ALL PLANS ARE CONSISTENT. | | | | | | 5. PLEASE NOTE THAT ALL SIGNAGE WILL NEED TO CONFORM TO | | | THE REQUIREMENTS OF THE GENERAL COMMERCIAL (GC) ZONING | | | DISTRICT AND WILL BE REVIEWED UPON SUBMITTAL. | | | | | | 6. ALL MECHANICAL AND ELECTRICAL EQUIPMENT (I.E. | | | TRANSFORMERS ON THE WEST SIDES OF BUILDINGS #1 AND #2), | | | WILL NEED TO BE SCREENED. | | | | | | 7. THE EXISTING LIGHT POLE SHOWN IN THE INVENTORY | | | PARKING AREA CONFLICTS WITH THE DRIVE AISLE AND WILL | | | NEED TO BE REMOVED OR RELOCATED. | | | | | | 8. THE EXISTING LIGHT POLE SOUTH OF THE BODY SHOP | | | CONFLICTS WITH A PARKING SPACE. THIS SPACE WILL NEED TO | | | BE STRIPED AS ?NO PARKING? OR THE POLE WILL NEED TO BE | | | REMOVED OR RELOCATED. | | | | | | BUILDING #1: | | | | | | 1. THE TWO (2) STAIRWAYS ON THE SOUTH SIDE OF BUILDING | | | 1, FROM THE ELEVATED DISPLAY AREA, ENCROACH IN THE | | | PARKING SPACES PROPOSED. | | | | | | 2. THE FLOOR PLANS DO NOT MATCH THE ELEVATIONS. THE | | | HANDICAP RAMP IS SHOWN GOING IN DIFFERENT DIRECTIONS. | | | | | | 3. THE FLOOR PLAN SHOWS DOORWAYS EXISTING THE EAST | | | FACADE OF THE BUILDING FROM THE DETAIL AND EXPRESS OIL | | | OFFICES. A LANDSCAPE ISLAND IS BEING PROPOSED JUST EAST | | | OF THESE DOORWAYS. THEREFORE, IT APPEARS THAT THE | | | EXITING OF THESE OFFICES WILL CONFLICT WITH THE | | | PROPOSED LANDSCAPING. | | | | | | BUILDING #2: | | | | | | 1. THE STAIRWAYS AND HANDICAP RAMP ON THE SOUTH SIDE OF | | | THE BUILDING APPEAR TO CONFLICT WITH THE PROPOSED | | | PARKING LAYOUT. | | | | | | 2. THE VEHICLE RAMP PROPOSED ON THE EAST SIDE OF THE | | | BUILDING APPEARS TO ENCROACH INTO THE DRIVEWAY BETWEEN | | | BUILDINGS #1 AND #2. THIS DRIVEWAY SHALL REMAIN 24 FEET | | | IN CLEAR WIDTH. THIS WILL NEED TO BE VERIFIED ON THE | | | SITE PLAN. | | | | | | BUILDING #3 | | | | | | 1. PLEASE NOTE THAT THE TITLE BLOCK ON SHEET 3-A4.0 AND | | | SHEET 3-A5.0 INDICATE BUILDING #1, WHEN THEY SHOULD | | | INDICATE BUILDING #3. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | PLANNING AND ZONING DEPARTMENT | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM | | | |
|
|
|