Plan Review Details - Permit 11070543
| Plan Review Stops For Permit 11070543 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-08-10 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-08-10 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-08-10 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-07-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-07-22 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-07-22 |
Time |
16:24 |
Sent To |
M |
|
| Notes |
| 2011-07-22 16:36:58 | 1 NORTH CLEMATIS STREET, 4TH FLOOR | | | PERMIT #11070543 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PLANS AND HYDRAULIC CALCULATIONS INDICATE A REMOTE AREA | | | OF 1500 SQUARE FEET BUT ONLY SEVEN SPRINKLERS AND | | | ROUGHLY 800 SQUARE FEET HAVE BEEN HYDRAULICALLY | | | CALCULATED. | | | | | | PER NFPA 13 THE HYDRAULIC AREA SHALL BE MEASURED | | | PARALLEL TO THE BRANCH LINES. | | | | | | HYDRAULIC CALCULATIONS DO NOT ACCOUNT FOR THE | | | ADDITIONAL FRICTION LOSS ASSOCIATED WITH THE FLEXIBLE | | | DROPS SUPPLYING SPRINKLERS. | | | | | | INDICATE ON THE PLANS THE MAXIMUM LENGTH OF FLEXIBLE | | | DROPS TO BE USED, THE MINIMUM BENDING RADIUS AND THE | | | MAXIMUM NUMBER OF BENDS PERMITTED PER THE LISTING | | | REQUIREMENTS. | | | | | | FOR SYSTEM PRESSURES EXCEEDING 100 PSI, THE HARD PIPED | | | SPRINKLERS SHALL BE PROTECTED FROM UPWARD MOVEMENT. | | | INDICATE THE METHOD FOR RESTRAINING UPWARD MOVEMENT AND | | | ADJUST PIPE HANGER LOCATION SCHEDULE AND ARMOVER DETAIL | | | FOR 100 PSI. | | | | | | THE REQUIRED RESIDUAL PRESSURE SHOWN ON THE PLANS IS A | | | NEGATIVE NUMBER. | | | | | | PROVIDE A FLOOR DESIGNATION IN THE TITLE BLOCK OR ON | | | THE PLANS. | | | | | | NOTE: ONLY THE BRAIDED FLEXIBLE HOSE ASSEMBLIES ARE | | | ACCEPTED BY THE OFFICE OF THE FIRE MARSHAL. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-08-10 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-08-10 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-08-08 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2011-08-08 16:33:35 | INCOMING SENT TO FIRE BOX. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-07-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-07-28 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-07-22 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2011-07-22 08:12:05 | TO FIRE |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2011-07-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-07-28 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-07-28 |
Time |
06:50 |
Sent To |
|
|
| Notes |
|
|
|