| 2011-07-29 13:31:27 | BUILDING REVIEW APPROVED WITH PROVISO: |
| | |
| | 1- REVISE LOAD SCHEDULE ON SHEET C-1 AND A-1. A) NEED |
| | TO ADD THE ATTIC LIVE LOAD AS REQUIRED BY TABLE R301.5. |
| | B) REVISE ROOF DEAD LOAD. NEED TO INCLUDE THE ROOF TILE |
| | WEIGHT AND ALL OTHER DEAD LOADS. |
| | |
| | 2- PROVIDE COMPLETE INFORMATION FOR COVERED PATIO #2 |
| | SCREEN ENCLOSURE UNDER A SEPARATE PERMIT. |
| | |
| | 3- SPECIFY WINDOW TYPE AND SIZE FOR ROOMS CALLED OFFICE |
| | AND DEN TO VERIFY COMPLIANCE WITH THE EGRESS |
| | REQUIREMENTS. SEC. R310. |
| | |
| | 4- PROVIDE COMPLETE MANUFACTURER SPECIFICATIONS FOR |
| | APPROVED GAS GRILL TO BE INSTALLED IN THE COVERED PATIO |
| | AS SHOWN ON PLANS. |
| | |
| | 5- PROVIDE UL LISTING AND COMPLETE SPECIFICATIONS FOR |
| | VENT LESS GAS FIREPLACE AS SHOWN ON PLANS. |
| | |
| | 6- PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR STEEL |
| | COLUMNS AT BASE. SPECIFY ALL FASTENERS, PLATE SIZE, |
| | ETC. |
| | |
| | 7- PROVIDE SPECIFICATIONS FOR GARAGE DOOR OPENING |
| | PROTECTION AS REQUIRED BY SEC. R309.1. |
| | |
| | 8- REVISE DRAINAGE ARROWS SHOWN ON THE SURVEY TO COMPLY |
| | WITH SEC. R401.3. DRAINAGE CAN'T BE DIRECTED TO THE |
| | GOLF COURSE. |
| | |
| | 9- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: A) ROOF TILE. INFORMATION SUBMITTED |
| | IS NOT A PRODUCT APPROVAL. B)TILE POLYFOAM. PROVIDE |
| | COMPLETE INFORMATION. ONLY FLORIDA PRODUCT APPROVAL |
| | COVER PAGE WAS SUBMITTED. C) ROOF RIDGE. PROVIDE |
| | COMPLETE INFORMATION. ONLY THE FLORIDA PRODUCT APPROVAL |
| | COVER PAGE WAS SUBMITTED. D) PRECAST LINTELS A SHOWN ON |
| | PLANS, INCLUDING THE 6" LINTEL AT ENTRY DOOR. E) WINDOW |
| | MULLIONS. NOA 06-0125.08 SUBMITTED EXPIRED ON 6/28/11. |
| | F) GARAGE DOOR. NOA 08-0718.01 SUBMITTED WAS SUPERSEDED |
| | BY MIAMI-DADE. |
| | |
| | 10- ARCHITECT TO REVIEW AND APPROVE IN WRITING ALL |
| | PRODUCT APPROVALS. SEC. 106.3.3 CITY AMENDMENTS. |
| | |
| | 11- ARCHITECT TO PROVIDE COMPLETE SPECIFICATIONS |
| | SHOWING COMPLIANCE WITH THE UNVENTED ATTIC AS SPECIFIED |
| | ON THE ENERGY CALCULATIONS. SEC. R806. |
| | |
| | 12- PROVIDE GARAGE DOOR AND ALL OTHER DOORS AND WINDOWS |
| | STRUCTURAL BUCK DETAILS/SPECIFICATIONS. |