Plan Review Details - Permit 11070434
Plan Review Stops For Permit 11070434
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-08-18 Cont ID  
Sent By jwitmer Date 2011-08-18 Time 10:12 Rev Time 0.00
Received By jwitmer Date 2011-08-18 Time 10:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-07-25 Cont ID  
Sent By jwitmer Date 2011-07-25 Time 08:51 Rev Time 0.77
Received By jwitmer Date 2011-07-25 Time 08:51 Sent To  
Notes
2011-07-25 09:48:19BUILDING PLAN REVIEW
 PERMIT: 11070434
 ADD: 100 S DIXIE HWY #200
 CONT: GERALD CONTRACTING, INC
 TEL: (561)281-52251
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) DISCREPANCIES IN PLANS:
 1A) THE COVER SHEET INDICATES THIS BUILDING TYPE AS A
 III-B WHERE AS SHEET 1.0A INDICATES THE BUILDING TYPE
 TO BE A BUILDING TYPE-II-B.
  
 1B) THE COVER SHEET ALSO INDICATES THE MINIMUM INTERIOR
 FINISH CLASSIFICATION TO BE A SPRINKLERED BUILDING,
 SHEEET 1.0A UNDER SCOPE OF WORK INDICATES THE BUILDING
 TO BE UNSPRINKLERED.
  
 1C) THE COVER SHEET THE KEY PLAN INTHE UPPER LEFT
 CORNER OF THE PLAN INDICATES A THIRD STAIRWAY WHERE AS
 ON SHEET 1.0A NEITHER THE DEMO OR THE FLOOR PLAN SHOWS
 THIS CONFIGURATION.
  
 2) PLANS INDICATE A LEVEL 3 ALTERATION PLEASE REVIEW
 THE DEFINITION FOR LEVEL THREE ALTERATIONS 2007/09
 EXISTING BUILDING CODE 405.1 WHERE 50% OF THE AGGREGATE
 AREA OF THE BUILDING AND MADE WITHIN ANY 12-MONTH
 PERIOD.
  
 3) ADDITIONAL INFORMATION REQUIRED. SHET 1.0A DOES NOT
 PROVIDE COMPLIANCE WITH SEPERATING THE COMMON AREAS
 WITH TENAT SEPERATION WALLS SECTION FBC-B 708.1(7) AND
 SECTION 2007 FBC-B 1017.1 & TABLE 1017.1 BUSINES
 OCCUPANCIES/ UNSPRINKLERED BUILDING WITH AN OCCUPANT
 LOAD > THAN 30.
 3A) PLEASE PROVIDE FIRE RATING ON DOOR NUMBERS 3,4 &5.
 2007 FBC-B TABLE 715.4.
  
 4) THE MECHANICAL SHEET SHOWS DUCTS PENETRATING FWALLS
 THAT SHOULD BE 1 HOUR FIRE RATING PLEASE SHOW
 COMPLIANCCE WITH 2007 FBC-B 712.2.3.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-08-17 Cont ID  
Sent By rlecky Date 2011-08-17 Time 08:26 Rev Time 0.00
Received By rlecky Date 2011-08-17 Time 08:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-07-27 Cont ID  
Sent By rlecky Date 2011-07-27 Time 10:19 Rev Time 0.00
Received By rlecky Date 2011-07-27 Time 10:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-08-18 Cont ID  
Sent By wjolin Date 2011-08-18 Time 09:57 Rev Time 0.00
Received By wjolin Date 2011-08-18 Time 09:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2011-07-26 Cont ID  
Sent By wjolin Date 2011-07-26 Time 13:36 Rev Time 0.00
Received By wjolin Date 2011-07-26 Time 12:38 Sent To  
Notes
2011-07-26 13:35:20100 SOUTH DIXIE HIGHWAY, SUITE #100
 PERMIT #11070434
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE ADDRESS ON THE PLANS DOES NOT MATCH THE ADDRESS ON
 THE PERMIT APPLICATION.
  
 NO FIRE ALARM INFORMATION PROVIDED ON PLANS.
  
 CLARIFY WHICH FIXTURES ARE EXIT SIGN ONLY AND WHICH
 FIXTURES ARE COMBINATION EXIT SIGN AND EMERGENCY
 LIGHTS.
  
 PROVIDE ADDITIONAL EXIT SIGN NEAR DOOR 6.
  
 INDICATE ANY FIRE RATED WALLS AND DOORS.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-08-24 Cont ID  
Sent By hmoser Date 2011-08-24 Time 10:16 Rev Time 0.00
Received By hmoser Date 2011-08-16 Time 16:01 Sent To  
Notes
2011-08-16 16:01:20B14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-08-02 Cont ID  
Sent By hmoser Date 2011-08-02 Time 07:49 Rev Time 0.00
Received By hmoser Date 2011-07-19 Time 13:57 Sent To  
Notes
2011-07-19 14:03:02B2

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-08-24 Cont ID  
Sent By hmoser Date 2011-08-24 Time 10:16 Rev Time 0.00
Received By hmoser Date 2011-08-24 Time 09:40 Sent To  
Notes
2011-08-24 10:28:35REFER TO SECTION 606.2.1 FAN SHUTDOWN AND
 606.4.1 SUPERVISION 2007 FBC (M)
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-08-02 Cont ID  
Sent By hmoser Date 2011-08-02 Time 07:48 Rev Time 0.00
Received By hmoser Date 2011-08-02 Time 07:05 Sent To  
Notes
2011-08-02 07:30:09PASS PROVISO
 REFER TO SECTION 606.2.1 SUPPLY SYSTEM,
 AND SECTION 606.3 INSTALLATION 2007 FBC (M)
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]