Plan Review Details - Permit 11070335
Plan Review Stops For Permit 11070335
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-08-31 Cont ID  
Sent By jwitmer Date 2011-08-31 Time 11:33 Rev Time 0.77
Received By jwitmer Date 2011-08-31 Time 11:33 Sent To  
Notes
2011-08-31 11:42:01BUILDING PROVISO:
 A SEPERATE ROOFING PERMIT IS REQUIRED.
 ROOFING REPORT SUBMITTED IS:
 FL#5444-R2
 ER 3532.09.05-R2
 CERTAIN TEED ASPHALT ROOFING SHINGLES
 NOTE 2007/09 FBC-R 905.2.7 UNDERLAYMENT FOR SHINGLES
 BETWEEN 2/12 AND 4/12 REQUIRE TWO LAYERS OF
 UNDERLAYMENT LAPPED 19".
  
  
 NO PRODUCT APPROVALS WERE SUBMITTED FOR PORCH ROOF
 SINGLE PLY ROOFING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-08-05 Cont ID  
Sent By jwitmer Date 2011-08-05 Time 11:23 Rev Time 0.77
Received By jwitmer Date 2011-08-05 Time 11:23 Sent To  
Notes
2011-08-05 11:51:27BUILDING PLAN REVIEW
 PERMIT: 11070335
 ADD: 223 PINE ST
 CONT: HIRE ME HANDY INC
 TEL: (561)267-5655
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS *
 WEST PALM BEACH AMENDMENTS
 2007 EXISTING BUILDING CODE W/ 2009 FBC SUPPLEMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1) REVIEW
 ACTION: DENIED
  
 PLANS INDICATE THIS TO BE A CHANGE OF OCCUPANCY SO THIS
 REVIEW WILL REFLECT THE SAME. FROM A R3 TO B OCCUPANCY.
 2007/09 EXST BLD CODE 901.3 CHANGE OF OCCUPANCY
 CLASSIFICATION. WHERE THE OCCUPANCY CLASSIFICATION OF A
 BUILDING CHANGES, THE PROVISIONS OF SECTIONS 902
 THROUGH 912 SHALL APPLY. THIS INCLUDES A CHANGE OF
 OCCUPANCY CLASSIFICATION WITHIN A GROUP AS WELL AS A
 CHANGE OF OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A
 DIFFERENT GROUP.
  
  
 903.1 GENERAL. BUILDING ELEMENTS AND MATERIALS IN
 PORTIONS OF BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY
 CLASSIFICATION SHALL COMPLY WITH SECTION 912.
  
  
 905.1 GENERAL. MEANS OF EGRESS IN PORTIONS OF BUILDINGS
 UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL
 COMPLY WITH SECTION 912.
  
 906.1 GENERAL. ACCESSIBILITY IN PORTIONS OF BUILDINGS
 UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL
 COMPLY WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE,
 BUILDING .
  
 1A) 907.1 GRAVITY LOADS. BUILDINGS OR PORTIONS THEREOF
 SUBJECT TO A CHANGE OF OCCUPANCY WHERE SUCH CHANGE IN
 THE NATURE OF OCCUPANCY RESULTS IN HIGHER UNIFORM OR
 CONCENTRATED LOADS BASED ON THE FLORIDA BUILDING CODE,
 BUILDING TABLES 1607.1 AND 1607.6 (HIGH-VELOCITY
 HURRICANE ZONES SHALL COMPLY WITH TABLE 1615.2) SHALL
 COMPLY WITH THE GRAVITY LOAD PROVISIONS OF THE FLORIDA
 BUILDING CODE, BUILDING . EXCEPTION: STRUCTURAL
 ELEMENTS WHOSE STRESS IS NOT INCREASED BY MORE THAN 5
 PERCENT.
  
 1B) PRODUCT APPROVALS WERE SUBMITTED FOR REPLACEMENT OF
 NON-IMPACT WINDOWS, STORM PANELS AND BAHAMA SHUTTERS,
 THE PLANS DO NOT IDENTIFY AS TO WHICH WINDOWS THESE
 ELEMENTS ARE GOING TO BE INSTALLED NOR IS THERE WIND
 DESIGN CRITERIA TO REVIEW THE APPROVAL TOO. THE OTHER
 ISSUE WITH THE STORM SHUTTER AND BAHAMA SHUTTER PLEASE
 CIRCLE THE SECTIONS TO BE USED IN EACH INSTALATION,
 TYPE OF FASTENER, SHUTTER SPANS, IF SHUTTERS ARE TO BE
 HORIZONTAL OR VERTICAL, EDGE DISTANCE FROM OPENING.
 2007/09 FBC-B 1609. COMPONENTS & CLADDING.
  
 PLEASE REVIEW 2007 FBC-B TABLE 1607.1 LIVE LOADS FOR A
 R-3 OCCUPANCY ARE 30 LBS FOR SLEEPING ROOMS AND 40 LBS
 FOR HABITAL AREAS. FOR A BUSINESS OCCUPANCY THESE FLOOR
 LOADS WILL BE INCREASED TO 50 PSF.
  
 2) 912.1.4 ACCESSIBILITY. ALL BUILDINGS UNDERGOING A
 CHANGE OF OCCUPANCY CLASSIFICATION SHALL COMPLY WITH
 SECTION 912.8
 912.8 ACCESSIBILITY. EXISTING BUILDINGS OR PORTIONS
 THEREOF THAT UNDERGO A CHANGE OF GROUP OR OCCUPANCY
 CLASSIFICATION SHALL COMPLY WITH CHAPTER 11 OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2007/09 FBC-B 11-4.1.6(2) ALTERATIONS TO AN AREA
 CONTAINING A PRIMARY FUNCTION. IN ADDITION TO THE
 REQUIREMENTS OF SECTION 11-4.1.6(1), AN ALTERATION THAT
 AFFECTS OR COULD AFFECT THE USABILITY OF OR ACCESS TO
 AN AREA CONTAINING A PRIMARY FUNCTION SHALL BE MADE SO
 AS TO ENSURE THAT, TO THE MAXIMUM EXTENT FEASIBLE, THE
 PATH OF TRAVEL TO THE ALTERED AREA AND THE RESTROOMS,
 TELEPHONES, AND DRINKING FOUNTAINS SERVING THE ALTERED
 AREA, ARE READILY ACCESSIBLE TO AND USABLE BY
 INDIVIDUALS WITH DISABILITIES, UNLESS SUCH ALTERATIONS
 ARE DISPROPORTIONATE TO THE OVERALL ALTERATIONS TIN
 TERMS OF COST AND SCOPE.
  
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO ALTERED AREAS SHALL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20 PERCENT OF THE COST OF THE ALTERATION
 TO THE PRIMARY FUNCTION AREA.
  
 DUTY TO PROVIDE ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
  
 (1) WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE
 PATH OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS.
  
 (2)(A) IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO
 PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE ELEMENTS
 THAT WILL PROVIDE THE GREATEST ACCESS, IN THE FOLLOWING
 ORDER:
  
 (I) AN ACCESSIBLE ENTRANCE; STAIRS ARE SHOWN WILL
 REQUIRE AN ACCESSIBLE RAMP. PLEASE REVIEW FBC-B 11-4.8
 RAMPS.
  
 (II) AN ACCESSIBLE ROUTE TO THE ALTERED AREA:
  
 (III) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR
 A SINGLE UNISEX RESTROOM:
  
 (IV) ACCESSIBLE TELEPHONES;
  
 (V) ACCESSIBLE DRINKING FOUNTAINS; AND
  
 (VI) WHEN POSSIBLE, ADDITIONAL ACCESSIBLE ELEMENTS SUCH
 AS PARKING, STORAGE, AND ALARMS.
  
  
 3) 912.1.2 FIRE PROTECTION AND INTERIOR FINISH. THE
 PROVISIONS OF SECTIONS 912.2 AND 912.3 FOR FIRE
 PROTECTION AND INTERIOR FINISH, RESPECTIVELY, SHALL
 APPLY TO ALL BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY
 CLASSIFICATION.
  
  
 4) 912.4.3 EGRESS CAPACITY. EGRESS CAPACITY SHALL MEET
 OR EXCEED THE OCCUPANT LOAD AS SPECIFIED IN THE FLORIDA
 BUILDING CODE, BUILDING , FOR THE NEW OCCUPANCY.
  
 5) 912.4.4 HANDRAILS. EXISTING STAIRWAYS SHALL COMPLY
 WITH THE HANDRAIL REQUIREMENTS OF SECTION 705.9 IN THE
 AREA OF THE CHANGE OF OCCUPANCY CLASSIFICATION.
  
 6) 912.4.5 GUARDS. EXISTING GUARDS SHALL COMPLY WITH
 THE REQUIREMENTS IN SECTION 705.10 IN THE AREA OF THE
 CHANGE OF OCCUPANCY CLASSIFICATION.
  
 7) PLANS INDICATE THE INSTALATION OF NEW ROOFING
 ASSEMBLIES, NO PRODUCT AAPPROVALS WERE SUBMITTED AT
 THIS TIME. FBC-B 1609 COMPONENTS & CLADDING.
  
 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2011-09-08 Cont ID  
Sent By rlecky Date 2011-09-08 Time 15:58 Rev Time 0.00
Received By rlecky Date 2011-09-08 Time 15:58 Sent To  
Notes
2011-09-08 15:59:18NO ELECTRIC REPAIR OR CHANGES PROPOSED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-08-04 Cont ID  
Sent By rlecky Date 2011-08-04 Time 14:11 Rev Time 0.00
Received By rlecky Date 2011-08-04 Time 14:09 Sent To  
Notes
2011-08-04 14:12:50ELECTRICAL PLANS REQUIRED FOR REPAIRED AREAS. NEW
 CONSTRUCTION MUST COMPLY WITH THE 2008 NEC.
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status N Date 2011-08-30 Cont ID  
Sent By wjolin Date 2011-08-30 Time 10:07 Rev Time 0.00
Received By wjolin Date 2011-08-30 Time 09:56 Sent To  
Notes
2011-08-30 10:07:26223 PINE STREET
 PERMIT #11070335
  
 PLANS CORRECTED FROM "CHANGE OF OCCUPANCY (BUSINESS)"
 TO "CODE VIOLATION REPAIRS (RESIDENTIAL)." NO REVIEW
 REQUIRED BY FIRE DEPARTMENT FOR REPAIRS TO SINGLE
 FAMILY HOME.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2011-07-26 Cont ID  
Sent By wjolin Date 2011-07-26 Time 12:35 Rev Time 0.00
Received By wjolin Date 2011-07-26 Time 12:26 Sent To  
Notes
2011-07-26 12:35:56223 PINE STREET
 PERMIT #11070335
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PLANS INDICATE A CHANGE OF OCCUPANCY TO BUSINESS
 OCCUPANCY.
  
 DESIGN SHALL CONFORM TO THE FLORIDA FIRE PREVENTION
 CODE 2007 EDITION: NFPA 1 AND NFPA 101 - 2006 EDITION
 WITH FLORIDA AMENDMENTS.
  
 PROVIDE BUILDING ADDRESS VISIBLE FROM THE STREET.
 NUMBERS SHALL BE AT LEAST SIX-INCHES IN HEIGHT AND
 SHALL CONTRAST THE BACKGROUND (REFERENCE: SECTION
 10.12.1.2 OF THE FLORIDA FIRE PREVENTION CODE ? NFPA
 1).
  
 STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS
 CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO
 THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R/F/RF
 DESIGNATION PER FLORIDA STATUTE 633.027 AND FLORIDA
 ADMINISTRATIVE CODE 69A-60.0081.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 STAIRS AND EGRESS COMPONENTS SHALL CONFORM TO THE LIFE
 SAFETY REQUIREMENTS OF CHAPTER 7 OF NFPA 101 FLORIDA
 2007 EDITION.
  
 HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIR.
 HANDRAILS SHALL BE LOCATED NOT LESS THAN 34 INCHES AND
 NOT MORE THAN 38 INCHES ABOVE THE SURFACE OF THE TREAD,
 MEASURED VERTICALLY TO THE TOP OF THE RAIL FROM THE
 LEADING EDGE OF THE TREAD. HANDRAIL ENDS SHALL BE
 RETURNED TO THE WALL OR FLOOR OR SHALL TERMINATE AT
 NEWEL POSTS. HANDRAIL CROSS SECTION SHALL HAVE A
 DIAMETER OF NOT LESS THAN 1.25 INCHES AND NOT MORE THAN
 2 INCHES.
  
 STAIR RISERS SHALL BE BETWEEN 4 INCHES AND 7 INCHES IN
 HEIGHT. STAIRS SHALL BE SLIP RESISTANT AND HAVE A
 MINIMUM TREAD DEPTH OF 11 INCHES AND PREVENT THE
 ACCUMULATION OF WATER.
  
 PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 THE RELEASING MECHANISM ON ALL DOORS SHALL OPEN THE
 DOOR WITH NOT MORE THAN ONE RELEASING OPERATION. THE
 RELEASING MECHANISM SHALL HAVE AN OBVIOUS METHOD OF
 OPERATION THAT IS READILY OPERATED UNDER ALL LIGHTING
 CONDITIONS. THE RELEASING DEVICE SHOULD BE CAPABLE OF
 BEING OPERATED WITH ONE HAND AND SHOULD NOT REQUIRE
 TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST
 TO OPERATE PER SECTION 7.2.1.5.9 OF NFPA 101 FLORIDA
 EDITION 2007.
  
 PROVIDE A LIFE SAFETY PLAN SHOWING ALL ROOM NAMES,
 FURNITURE, EXITS, EXIT SIGNS, EMERGENCY LIGHTING,
 TRAVEL DISTANCES, COMMON PATH OF TRAVEL ETC.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-09-14 Cont ID  
Sent By lmartine Date 2011-09-13 Time 15:39 Rev Time 0.00
Received By lmartine Date 2011-08-26 Time 15:11 Sent To  
Notes
2011-08-26 15:12:04B14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-08-04 Cont ID  
Sent By rlecky Date 2011-08-05 Time 15:38 Rev Time 0.00
Received By lmartine Date 2011-07-15 Time 09:41 Sent To  
Notes
2011-07-25 10:02:07B22
  
2011-07-15 10:29:21MISC. 1

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2011-09-15 Cont ID  
Sent By lmartine Date 2011-09-15 Time 10:19 Rev Time 0.00
Received By lmartine Date 2011-09-15 Time 10:19 Sent To  
Notes
2011-09-15 10:20:43NO CHANGE OF USE AND NO ADDITIONAL SQ. FOOTAGE ADDED.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2011-08-05 Cont ID  
Sent By jwitmer Date 2011-08-05 Time 11:22 Rev Time 0.00
Received By jwitmer Date 2011-08-05 Time 11:22 Sent To  
Notes
2011-08-05 11:22:45BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2011-08-04 Cont ID  
Sent By hmoser Date 2011-08-04 Time 13:44 Rev Time 0.00
Received By hmoser Date 2011-08-04 Time 13:43 Sent To  
Notes
2011-08-04 13:44:44NO MECHANICAL PLANS REQUIRED.

Review Stop P PLUMBING
Rev No 2 Status N Date 2011-08-29 Cont ID  
Sent By lwagner Date 2011-08-29 Time 14:38 Rev Time 0.00
Received By lwagner Date 2011-08-29 Time 14:06 Sent To  
Notes
2011-08-29 14:38:53NO PLUMBING WORK SHOWN AT THIS TIME

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-07-26 Cont ID  
Sent By lwagner Date 2011-07-26 Time 11:56 Rev Time 0.00
Received By lwagner Date 2011-07-26 Time 09:56 Sent To  
Notes
2011-07-26 13:02:38FBC 2007 PLUMBING PLAN REVIEW #1
 DENIED:
  
 THE APPLICATION IS CHECKED OFF FOR NO CHANGE OF
 OCCUPANCY AND THE PLAN HAS CHANGE OF OCCUPANCY STATED
 UPON IT. THERE IS NOT ENOUGH INFORMATION TO DO A
 PLUMBING REVIEW AT THIS TIME. THE TYPE OF OCCUPANCY AND
 OCCUPANT COUNT WILL DETERMINE THE FIXTURE COUNT,
 ACCESSIBILITY, ETC.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 2 Status P Date 2011-09-13 Cont ID  
Sent By astelly Date 2011-09-13 Time 13:56 Rev Time 0.00
Received By astelly Date 2011-09-13 Time 13:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2011-07-29 Cont ID  
Sent By astelly Date 2011-07-29 Time 16:42 Rev Time 0.00
Received By astelly Date 2011-07-29 Time 16:42 Sent To  
Notes
2011-07-29 16:43:06AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 PLEASE INDICATE THE NEW USE FOR THE PROPERTY.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved