| Plan Review Stops For Permit 11070290 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-09-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-09-19 |
Time |
14:01 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2011-09-19 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-07-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-07-18 |
Time |
10:09 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2011-07-15 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2011-07-18 10:32:16 | BUILDING PLAN REVIEW | | | PERMIT: 11070290 | | | ADD: 1120 13TH ST | | | CONT: GENERAL ENGINEERING & DEVELOPMENT | | | TEL: (561)509-4000 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | | | | 1) COVER SHEET INDICATES A MIXED USE OCCUPANCY AS | | | BUSINESS/ DAYCARE PLEASE INDICATE WHERE THE BUSINESS | | | PORTION OF THE MIXED USE OCCUPANCY IS LOCATED. THE | | | PLANS APPEAR TO BE A DAYCARE OCCUPANCY PER 2007/ 09 | | | FBC-B 202 DEFINITIONS AND SECTION 436 OF THE FBC-B. | | | | | | 2) PLEASE REVIEW THE OCCUPANT LOADS VERSES SQ FT, COVER | | | SHEET SEE FBC-B TABLE 1004.1.1DAYCARE 20 NET | | | | | | 3) OF THE OCCUPANT LOAD FOR THE DAYCARE OCCUPANCY HOW | | | MANY OF THE OCCUPANTS (CLIENTS) WILL BE 24 MONTHS OLD | | | OR LESS IN AGE ? 2007/09 FBC-B 436.2. | | | | | | 4) PLEASE UPDATE PLANS TO COMPLY WITH : | | | 4A) 436.2 CLOSET DOORS. EVERY CLOSET DOOR LATCH SHALL | | | BE SUCH THAT CLIENTS CAN OPEN THE DOOR FROM INSIDE THE | | | CLOSET. | | | | | | 4B) 436.3 BATHROOM DOORS. EVERY BATHROOM DOOR LOCK | | | SHALL BE DESIGNED TO PERMIT OPENING OF THE LOCKED DOOR | | | FROM THE OUTSIDE IN AN EMERGENCY. THE OPENING DEVICE | | | SHALL BE READILY ACCESSIBLE TO THE STAFF. | | | | | | 4C) 436.4 DOOR CLOSURE. ANY EXIT DOOR DESIGNED TO BE | | | NORMALLY CLOSED SHALL BE KEPT CLOSED AND SHALL COMPLY | | | WITH SECTION 715.3. | | | | | | 5) 2007/09 FBC-B 436.1 & 436.2 PLEASE PROVIDE | | | INFORMATION ON ROOMS OR AREAS OF CONCERN SINCE THEY ARE | | | NOT INDICATED ON THE PLANS: | | | 5A) 436.1(3.) ROOMS OR SPACES USED FOR THE STORAGE OF | | | HAZARDOUS MATERIALS OR FLAMMABLE OR COMBUSTIBLE LIQUIDS | | | IN QUANTITIES DEEMED HAZARDOUS BY RECOGNIZED STANDARDS. | | | | | | 5B) 436.1(4) JANITOR CLOSETS. | | | | | | 5C) 436.6.2 ( 1.) LAUNDRIES. | | | | | | 5D) 436.2 (4.) ROOMS OR SPACES USED FOR PROCESSING OR | | | USE OF HAZARDOUS MATERIALS (CLEANING PRODUCTS) OR | | | FLAMMABLE OR COMBUSTIBLE LIQUIDS IN QUANTITIES DEEMED | | | HAZARDOUS BY RECOGNIZED STANDARDS. | | | | | | 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-09-13 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-09-13 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-09-13 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-07-20 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-07-20 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-07-19 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2011-07-20 09:25:46 | PROVIDE AN ELECTRICAL PLAN. NEC 215.5 | | | MAXIMUM OVERCURRENT PROTECTION FOR #3 SERVICE | | | CONDUCTORS AT MAIN DISCONNECT IS 100 AMPERES. NEC T. | | | 310.16 | | | ALL RECEPTACLES SHALL BE TAMPER RESISTANT. NEC 406.11 | | | RECEPTACLES IN BATHROOMS, KITCHEN AREAS AND OUTDOORS | | | SHALL BE GFCI PROTECTED. NEC 210. 8 | | | | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2012-09-14 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2012-09-14 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
mgonzale |
Date |
2012-09-14 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2012-09-14 15:31:25 | PLAN DOES NOT CONFLICT WITH CITY OF WPB PUBLIC | | | UTILITIES. | | | | | | PLAN WILL REQUIRE A ROW PERMIT FOR OFF-SITE PARKING AND | | | USE OF 15' ALLEYWAY. | | | | | | CONTACT CITY OF WEST PALM BEACH ENGINEERING SERVICES | | | DEPARTMENT. | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-09-06 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-09-06 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-09-06 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-07-21 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-07-21 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-07-20 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2011-07-20 16:57:28 | 1120 13TH STREET | | | PERMIT #11070290 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PROVIDE BUILDING ADDRESS VISIBLE FROM THE STREET. | | | NUMBERS SHALL BE AT LEAST SIX-INCHES IN HEIGHT AND | | | SHALL CONTRAST THE BACKGROUND (REFERENCE: SECTION | | | 10.12.1.2 OF THE FLORIDA FIRE PREVENTION CODE - NFPA | | | 1). | | | | | | STRUCTURES WITH LIGHT FRAME ROOF TRUSS CONSTRUCTION | | | SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO THE | | | BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS | | | 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED | | | REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R | | | DESIGNATION PER FLORIDA STATUTE 633.027 AND FLORIDA | | | ADMINISTRATIVE CODE 69A-60.0081. | | | | | | PORTABLE FIRE EXTINGUISHERS SHALL HAVE A MINIMUM RATING | | | OF 2A:10BC AND SHALL BE TAGGED BY A LICENSED FIRE | | | EXTINGUISHER COMPANY. | | | | | | THE RELEASING MECHANISM ON ALL DOORS SHALL OPEN THE | | | DOOR WITH NOT MORE THAN ONE RELEASING OPERATION. THE | | | RELEASING MECHANISM SHALL HAVE AN OBVIOUS METHOD OF | | | OPERATION THAT IS READILY OPERATED UNDER ALL LIGHTING | | | CONDITIONS. THE RELEASING DEVICE SHOULD BE CAPABLE OF | | | BEING OPERATED WITH ONE HAND AND SHOULD NOT REQUIRE | | | TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST | | | TO OPERATE PER SECTION 7.2.1.5.9 OF NFPA 101 FLORIDA | | | EDITION 2007. | | | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | | EXIT SIGNS. | | | | | | INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE | | | CLASS A OR CLASS B. | | | | | | JANITOR CLOSETS SHALL BE SEPARATED FROM THE REST OF THE | | | BUILDING WITH A ONE-HOUR FIRE RESISTANCE RATING. | | | | | | EMERGENCY PLAN (EXIT LOCATIONS, EMERGENCY PHONE | | | NUMBERS, ETC) TO BE DEVELOPED AND POSTED IN BUILDING | | | PRIOR TO OCCUPANCY. | | | | | | EMERGENCY EGRESS DRILLS SHALL BE CONDUCTED MONTHLY. | | | | | | ARTWORK AND TEACHING MATERIALS ATTACHED TO THE WALLS | | | SHALL NOT EXCEED 20 PERCENT OF THE INDIVIDUAL WALL | | | AREA. | | | | | | FIRE PREVENTION INSPECTIONS SHALL BE CONDUCTED MONTHLY | | | BY A TRAINED SENIOR MEMBER OF THE STAFF, AFTER WHICH A | | | COPY OF THE LATEST INSPECTION REPORT SHALL BE POSTED IN | | | A CONSPICUOUS PLACE IN THE DAY-CARE FACILITY. IT SHALL | | | BE THE DUTY OF THE STAFF TO INSPECT ALL EXITS DAILY TO | | | ENSURE THAT ALL DOORS AND EXIT PATHS ARE MAINTAINED | | | CLEAR OF OBSTRUCTIONS. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2012-09-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-09-05 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-09-04 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2012-09-04 14:53:17 | GAVE TO JIM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-02-06 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2012-02-06 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-12-22 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2011-12-22 10:21:40 | INCOMING SENT TO AMEY S. DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-11-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-10-01 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-30 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2011-08-30 10:49:57 | INCOMING SENT TO B-3 .JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-08-08 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-08-08 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-07-14 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2011-07-14 13:38:57 | SENT TO SHELF B13 FOR ALL TRADES REVIEW. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2012-09-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-09-05 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-09-05 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2012-09-05 09:57:04 | IMPACT FEES: | | | RECEIPT # 2012-0803-115 | | | TRACKING# MU-2012-014194-0000 | | | FEES: $477.13 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2011-07-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-07-18 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2011-07-18 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2011-07-18 10:32:54 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-09-07 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-09-07 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-09-07 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2011-09-07 11:39:04 | REFER TO SECTION 602.2.1 MATERIALS EXPOSED WITHIN | | | PLENUMS 2007 FBC(M) . | | | IF MORE MECHANICAL WORK IS BEING DONE BESIDE BATH | | | EXHAUST THE MECHANICAL CONTRACTOR MUST | | | SUBMIT PLANS TO BE REVIEWED BY THE CITY. | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2011-08-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-08-08 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-08-08 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2011-08-08 13:03:25 | PLAN SUBMITTED IS FOR BATH EXHAUST ONLY. | | | AIR CONDITIONING SHOWS EXISTING. | | | REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-09-08 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-09-08 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-09-08 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-07-22 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-07-22 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-07-21 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2011-07-21 13:16:06 | FBC 2007 PLUNBING REVIEW # 1 | | | DENIED: | | | | | | 1. ONE SET OF PLANS THE DESIGNER OF RECORD IS A COPIED | | | SIGNATURE AND MISSING THE ARCHITECT'S SEAL. SANDRA | | | PUERTA, AR 95385. FL ADMINISTRATIVE RULE 61G-16.003 | | | | | | 2. COVER-SHEET PLUMBING FIXTURE CALULATIONS: | | | | | | 2A) WILL NEED TO BE BASED ON THE CORRECT BUILDING CODE | | | CLASSIFICATION OF DAYCARE OCCUPANCY, PLUMBING FIXTURE | | | COUNT IS BASED ON A BUSINESS OCCUPANCY. | | | | | | 2B) THE PLUMBING FIXTURE CALCULATIONS WILL NEED TO BE | | | BASED ON THE CORRECTED OCCUPANCY LOAD OF 20 OCCUPANTS | | | PER 2007/09 FBC-B TABLE 1004.1.1. INDICATE THE REQUIRED | | | FIXTURES FOR A DAYCARE OCCUPANCY PER 2007/09 FBC-P | | | TABLE 403.1(3) | | | EDUCATIONAL/ DAYCARE. | | | | | | 3) THE FLOOR PLAN ONLY SHOWS ONE RESTROOM THAT IS | | | ACCESSIBLE, IN REVIEWING FBC-P | | | TABLE 403.1(3) FOR BOTH MALE AND FEMALES 1/50 FOR BOTH | | | WATER CLOSETS AND LAVS SO TWO ACCESSIBLE RESTROOMS WILL | | | BE REQUIRED PER 403.2. 403.2 SEPARATE FACILITIES. WHERE | | | PLUMBING FIXTURES ARE REQUIRED, SEPARATE FACILITIES | | | SHALL BE PROVIDED FOR EACH SEX. | | | THE BUSINESS EXCEPTION DOES NOT MEET THE CRITERIA, NO | | | BUSINESS OCCUPANCY WAS INDICATED ON THE PLANS. | | | | | | 4) PLANS ARE MISSING THE WATER SUPPLY PIPING ISOMETRIC | | | PER 2007/09 106.5.1.3. | | | | | | 5) PLANS FAIL TO INDICATE COMPLIANCE WITH 2007/09 FBC-P | | | 608.13 BACKFLOW PROTECTION. MEANS OF PROTECTION AGAINST | | | BACKFLOW SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS | | | 608.13.1 THROUGH 608.13.9. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2012-02-06 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2012-02-06 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2012-02-06 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2012-02-06 12:00:51 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | PASSED W/ PROVISO | | | DRIVE AISLE SHALL BE MEASURED AT 24 FT. FROM EDGE OF | | | UTILITY POLE. 15.5 FT. OF PROVATE PROPERTY SHALL BE | | | DEVOTED TO PAVED DRIVE AISLE. OUTDOOR PLAY AREA AND | | | STUDENT CAPACITY MUST BE RE-CALCULATED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2011-10-01 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-10-01 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-10-01 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2011-10-01 10:15:11 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | REPEAT COMMENTS: | | | | | | PLEASE PROVIDE A SURVEY OF THE PROPERTY. | | | | | | CIRCULATION TO PARKING SPACES THROUGH AN UN-PAVED ALLEY | | | IS NOT ALLOWED. | | | | | | THE REQUIRED PARKING FOR DAYCARES IS ONE (1) SPACE PER | | | EMPLOYEE PLUS FIVE (5) VISITOR SPACES. A MINIMUM OF | | | SEVEN (7) SPACES IS REQUIRED. | | | | | | LANDSCAPING MUST BE INSTALLED PER SEC. 94-443 | | | | | | A SIGNED AND SEALED LANDSCAPE PLAN MUST BE SUBMITTED | | | PER SEC. 94-448 | | | | | | LANDSCAPED TERMINAL ISLANDS ARE REQUIRED AT THE ENDS OF | | | EACH PARKING ROW. | | | | | | THE GATE SHOWN ALONG CARVER AVE. IS NOT PERMITTED TO | | | SWING INTO THE RIGHT-OF-WAY. | | | | | | THE CIRCULATION /PICK-UP AREA SHOWN ON THE PLAN | | | INDICATES THAT GRASS WILL BE INSTALLED IN THE PAVEMENT | | | AREA OF THE RIGHT-OF-WAY. THIS IS NOT ALLOWED. PLEASE | | | SHOW PAVEMENT AREA AS IT EXISTS IN THE REVISED | | | DRAWINGS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-07-29 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-07-29 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-07-29 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2011-07-29 16:41:33 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | PLEASE PROVIDE A SURVEY OF THE PROPERTY. | | | CIRCULATION TO PARKING SPACES THROUGH AN UN-PAVED ALLEY | | | IS NOT ALLOWED. | | | THE REQUIRED PARKING FOR DAYCARES IS ONE (1) SPACE PER | | | EMPLOYEE PLUS FIVE (5) VISITOR SPACES. A MINIMUM OF | | | SEVEN (7) SPACES IS REQUIRED. | | | LANDSCAPING MUST BE INSTALLED PER SEC. 94-443 | | | A SIGNED AND SEALED LANDSCAPE PLAN MUST BE SUBMITTED | | | PER SEC. 94-448 | | | LANDSCAPED TERMINAL ISLANDS ARE REQUIRED AT THE ENDS OF | | | EACH PARKING ROW. | | | THE CIRCULATION /PICK-UP AREA MUST ALSO BE SHOWN ON THE | | | PLAN IN ACCORDANCE WITH TABLE XV-6 IN SEC. 94-486 OF | | | THE ZONING CODE. | | | THE GATE SHOWN ALONG CARVER AVE. IS NOT PERMITTED TO | | | SWING INTO THE RIGHT-OF-WAY. |
|
|