| 2011-07-19 13:47:22 | BUILDING PLAN REVIEW |
| | PERMIT: 11070120 |
| | ADD: 225 DYER RD #2 |
| | CONT: PALM BEACH WINDOW & DOOR |
| | TEL: (561)373-3902 |
| | |
| | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| | OFFICIAL . |
| | |
| | 1) THE THREE PICTURES SUBMITTED AS REFERENCE TO SCOPE |
| | OF WORK DOES NOT MATCH UP WITH THE FLOOR PLAN OF |
| | WINDOWS TO BE REPLACED. AN EXAMPLE THE 2ND FLOOR FLOOR |
| | PLAN INDICATES TWO SEPERATE WINDOWS WITH A WALL SECTION |
| | BETWEEN THEM WHEREAS THE PICTURE OF THE SECOND FLOOR |
| | INDICATES TWO DOUBLE HUNG WINDOWS WITH COUNTER BALANCE |
| | SASH COMPARTMENT, THERE IS USUALLY NO FRAMING MEMBERS |
| | BETWEEN THE TWO WINDOWS. |
| | |
| | 2.1) THE SECOND ISSUE IS THE PRODUCT APPROVAL SUBMITTED |
| | DOES NOT INDICATE ANY VERTICAL MULLIONS INCLUDED WITHIN |
| | THE PRODUCT APPROVAL. A SEPERATE MULLION REPORT WILL BE |
| | REQUIRED. 2007/09 FBC-B 1714.5.5 |
| | |
| | 2.2 PLEASE CIRCLE IN THE PRODUCT APPROVAL THE TYPE OF |
| | FASTENER TO BE USED FOR ANCHORING THESE WINDOWS AND |
| | TYPE OF MATERIAL THE WINDOWS WILL BE ANCHORED TO. IS |
| | THIS A WOOD FRAME/ STUCCO BUILDING? |
| | |
| | 3) THE FIRST FLOOR FLOOR PLAN APPEARS TO HAVE SIMILAR |
| | ISSUES THE WINDOWS ARE DRAWN IN AS TWO INDIVIDUAL |
| | WINDOWS WITH WALL SEECTION BETWEEN THEM AND THE FIRST |
| | FLOOR PICTURE INDICATES THE SAME TWO DOUBLE HUNG WOOD |
| | SASH WINDOWS WITH COUNTER BALANCE COMPARTMENT BETWEEN |
| | THEM AND NO MULLION REPORT. |
| | THE QUESTION IS ARE THERE ONLY TWO WINDOWS ON THE FIRST |
| | FLOOR THIS ELEVATION OR IS THERE TWO PAIR OF WINDOW ? |
| | |
| | 4) CONTRACTOR TO TAKE RESPONSIBILITY FOR PLANS |
| | SUBMITTED, AS THE DESIGNER OF RECORD, PLEASE PRINT |
| | NAME, SIGN YOUR NAME AND LICESNE NUMBER. |
| | |
| | 5) PLANS ARE MISSING WIND DESIGN CRITERIA: |
| | 1609.6.2 WIND DESIGN PROCEDURES |
| | 4.1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE |
| | ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION. |
| | |
| | 4.2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH SECTION1609.5. |
| | |
| | 4.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.4. |
| | |
| | 4.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| | SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4) |
| | |
| | 4.5 POSSITE & NEGATIVE PRESSURES |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |