Plan Review Details - Permit 11060719
| Plan Review Stops For Permit 11060719 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-08-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-08-03 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-08-03 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-07-26 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-07-26 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2011-07-26 13:25:15 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. SEE SHEET 16 OF THE PRODUCT APPROVAL. PLEASE REVISE | | | INSTALLATION SCHEDULE TO INCLUDE SHUTTER CONNECTION | | | MOUNTING TYPE. THIS SHOULD CORRELATE WITH THE ANCHOR | | | CHARTS (FOR EXAMPLE, M THROUGH X IF THE SUBSTRATE IS | | | WOOD). | | | | | | 2. THE ANCHOR SPACING PROPOSED (12") ON THE | | | INSTALLATION SCHEDULE DOES NOT COMPLY WITH THE | | | REQUIREMENTS OF THE PRODUCT APPROVAL FOR ANY OF THE | | | MOUNTING TYPES FOR WOOD SUBSTRATE. PLEASE REVISE | | | INSTALLATION SCHEDULE. | | | | | | 3. PRIOR TO RESUBMITTAL, PLEASE HAVE THE QUALIFIER | | | REVIEW INSTALLATION SCHEDULE FOR CODE COMPLIANCE. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-07-05 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-07-05 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2011-07-05 12:25:54 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | 2. THE PRODUCT APPROVAL HAS ANCHOR SPACING CIRCLED FOR | | | THREE DIFFERENT ANCHORS INTO CONCRETE SUBSTRATE. THE | | | BOTTOM IS TYPICALLY A CONCRETE BLOCK SUBSTRATE IN CBS | | | CONSTRUCTION. ONE STORY CONDOMINIUMS ARE USUALLY EITHER | | | FRAME OR CBS. EITHER PROVIDE INFORMATION AS TO HOW A | | | BOTTOM CONCRETE SUBSTRATE HAS BEEN DETERMINED OR | | | SPECIFY CBS BOTTOM SUBSTRATE (AND A SHUTTER CONNECTION | | | MOUNTING TYPE ALLOWED FOR CONCRETE BLOCK). | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-07-26 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-07-21 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2011-07-21 14:03:01 | TO SH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-07-05 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-06-28 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2011-06-28 13:06:18 | TO BLDG < $5K |
|
|
|