2011-06-23 18:29:36****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLEASE PROVIDE INFORMATION ON HOW YOU HAVE
 DETERMINED THAT THE BOTTOM SUBSTRATE IS CONCRETE RATHER
 THAN CONCRETE BLOCK. CBS HOMES TYPICALLY HAVE CONCRETE
 TOP SUBSTRATE, BLOCK BOTTOM. EITHER PROVIDE REQUESTED
 INFORMATION OR REVISE BOTTOM SUBSTRATE AND ANCHOR
 SPACING.
  
 2. PLEASE REVISE SPAN; THIS SHOULD EQUAL BLADE LENGTH
 (NOT OPENING SIZE). WITH A 2 1/2" EDGE DISTANCE, SPANS
 SHOULD BE A MINIMUM OF 2" LARGER THAN OPENING SIZES.
  
 3. PLEASE CLARIFY INSTALLATION, "H" IS SPECIFIED;
 ACCORDION SHUTTERS ARE TYPICALLY INSTALLED VERTICALLY.
 IF THE CLEAR PANEL IS TO BE INSTALLED HORIZONTALLY,
 SUBSTRATE IS CONCRETE BLOCK FOR BOTH SIDES (FILLED
 CELLS ARE BLOCK).
  
 4. THE INSTALLATION SCHEDULE DOES NOT INCLUDE THE SPANS
 ON THE FIRST SHEET, PLEASE REVISE.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-06-23 Cont ID  
Sent By shill Date 2011-06-23 Time 18:29 Rev Time 0.00
Received By shill Date 2011-06-21 Time 14:23 Sent To  
Notes
2011-06-21 14:24:08TO MISC 1
  