| Plan Review Stops For Permit 11060463 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-07-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-07-07 |
Time |
08:51 |
Rev Time |
0.40 |
| Received By |
jwitmer |
Date |
2011-07-07 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-08-16 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-08-16 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-08-16 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-07-07 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-07-07 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-07-07 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2011-07-07 09:35:53 | PHASE, AMPACITY, VOLTAGE AND WIRE SIZE NOT CLEARLY | | | INDICATED ON PLANS. SHEET E2 CONFLICTS WITH E5. | | | POWER CONDUCTORS NOT SHOW. CONDUITS MAY BE UNDERSIZED. | | | PROVIDE SPECIFICATION ON THE TRANSFERE SWITCH. PROVIDE | | | A SUMMARY LOAD CALCULATION. NEC 215. 5 | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2011-06-27 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-06-27 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-06-27 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2011-07-12 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-07-12 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-07-12 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2011-07-12 10:22:06 | GAS PERMIT REQUIRED |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-08-16 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-08-16 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-08-16 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2011-08-16 11:15:59 | TO ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-07-12 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-07-12 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-06-20 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2011-06-20 14:18:57 | SENT TO B2 SHELF FOR REVIEW. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2011-07-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-07-08 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-07-08 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2011-07-08 09:20:42 | PLAN SHOWS NATURAL GAS MUST GO TO PLUMBING. NO PLAN FOR | | | EXHAUST SUBMITTED. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2011-07-12 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-07-12 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-07-12 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-07-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2011-07-06 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2011-07-06 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2011-07-06 15:33:23 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 07.06.2011 | | | PERMIT NO.: 11060463 | | | ADDRESS: 1700 PALM BEACH LAKES BOULEVARD | | | CONTRACTOR/CONTACT: JOE BURGESS | | | TELEPHONE NO.: 561.282.4106 | | | SCOPE OF REVIEW: GAS GENERATOR TO POWER ATT CELL PHONE | | | EQUIPMENT (TO BE LOCATED ON 3RD FLOOR OF PARKING | | | GARAGE) | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. PRIOR TO ISSUANCE OF A CERTIFICATE OF COMPLETION, | | | THE GENERATOR SHALL BE PAINTED TO MATCH THE COLOR OF | | | THE SURROUNDING PARKING GARAGE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, SENIOR PLANNER | | | CITY OF WEST PALM BEACH | | | PLANNING AND ZONING DEPARTMENT | | | 401 CLEMATIS STREET - P.O. BOX 3366 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1435 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.CITYOFWPB.COM |
|
|