Plan Review Details - Permit 11060454
Plan Review Stops For Permit 11060454
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-06-24 Cont ID  
Sent By shill Date 2011-06-24 Time 09:41 Rev Time 0.00
Received By shill Date 2011-06-24 Time 09:41 Sent To  
Notes
2011-06-24 09:42:21****PROVISO****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
  
 PER CONTRACTOR, FOAM ADHESIVE WILL BE USED FOR ROOF
 TILE FASTENING. PROVIDE PRODUCT APPROVAL AT INSPECTION
 PRIOR TO INSTALLATION.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-06-21 Cont ID  
Sent By shill Date 2011-06-21 Time 15:46 Rev Time 0.00
Received By shill Date 2011-06-21 Time 15:46 Sent To  
Notes
2011-06-21 15:55:51****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLEASE CLARIFY INSTALLATION. IN MY CONVERSATION WITH
 OWNER, I WAS INFORMED THAT THE PROPOSED INSTALLATION IS
 A FLAT DECK. THE PLAN SHOWS TILE, AND TILE PRODUCT
 APPROVALS WERE SUBMITTED. ARCHITECT HAS SPECIFIED 30/90
 HOT MOP WITH TILE. IT IS NOT CLEAR WHERE THE POLYGLASS
 IS TO BE INSTALLED AS THIS PRODUCT WAS NOT DESIGNED AS
 A TILE UNDERLAYMENT.
  
 2. PLEASE HAVE THE ARCHITECT REVIEW PROPOSED
 INSTALLATION AND APPROVE.
  
 3. FOR A TILE ROOF, CIRCLE THE FASTENING PROPOSED ON
 THE PRODUCT APPROVAL. IF ADHESIVE IS TO BE USED,
 PROVIDE PRODUCT APPROVAL.
  
 4. HAVE THE ARCHITECT CLARIFY ROOF PITCH. THE PLAN
 STATES TO "MATCH EXISTING," GRAPHICALLY SHOWS A PITCHED
 ROOF, BUT I'VE BEEN INFORMED THAT THIS WILL BE A FLAT
 ROOF. PLEASE CLARIFY SO CODE COMPLIANCE CAN BE
 DETERMINED.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-06-20 Cont ID  
Sent By shill Date 2011-06-20 Time 11:06 Rev Time 0.00
Received By shill Date 2011-06-20 Time 11:06 Sent To  
Notes
2011-06-20 11:06:17****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED,
 FAC9N-3. PLEASE PROVIDE PRODUCT APPROVAL FOR THE
 PROPOSED ROOF COVERING.
  
 2. FOR THE FLAT DECK, INDICATE WHICH ASSEMBLY IS
 PROPOSED AND SPECIFY ENHANCED FASTENING FOR ZONES 2 AND
 3 (IF APPLICABLE). IF THE PRODUCT APPROVAL REQUIRES FOR
 THIS TO BE DONE BY AN ARCHITECT OR ENGINEER (SEE
 GENERAL LIMITATION #7, LAST PAGE OF NOA), PLEASE
 PROVIDE SIGNED & SEALED ENHANCED FASTENING
 CALCULATIONS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-06-21 Cont ID  
Sent By shill Date 2011-06-21 Time 15:56 Rev Time 0.00
Received By shill Date 2011-06-21 Time 14:37 Sent To  
Notes
2011-06-21 14:37:56TO SH DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-06-20 Cont ID  
Sent By shill Date 2011-06-20 Time 11:05 Rev Time 0.00
Received By shill Date 2011-06-20 Time 11:00 Sent To  
Notes
***NONE***