| Plan Review Stops For Permit 11060444 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-26 |
Time |
10:23 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2011-10-26 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2011-10-26 11:07:26 | ROOFING REVISION: | | | FL 11727.3 R1 | | | ENGLERT SERIES 1300 | | | STEEL 24 GAUGE | | | WOOD DECK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-08-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-08-17 |
Time |
12:51 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2011-08-17 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2011-08-17 12:57:09 | ROOFING PRODUCT APPROVALS: | | | | | | BERRIDGE MANUFACTURING ZEE-LOCK PANEL W/ CONTINUOUS | | | CLIP | | | NOA-1018.02 | | | FIELD -101PSF @ 16"OC FAASTENER SPACING | | | PERMITERS & CORNERS -174.25 @ 8" OC | | | | | | SIPLAST INC | | | NOA 07-1211.06 | | | PAGE 13 OF 15 | | | SBS WOOD INSULATED | | | -172.5 SEE LIMITATION # 7. | | | | | | WINDOWS: | | | YKK AP YOW 225 H NON-THERMAAL ALUMINUM FIXED WINDOW | | | L.M.I. | | | NOA 06-1016.07 | | | GLASS TYPE A -90 | | | GLASS TYPE B OR C -65. | | | | | | DOOR REPORT: | | | INDUSTRIAL MILLWORK "TENER LMI | | | NOA09-0511.05 | | | -50 MIN PRESS | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-06-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-06-30 |
Time |
11:10 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2011-06-29 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2011-06-30 12:57:46 | BUILDING PLAN REVIEW | | | PERMIT: 11060444 | | | ADD: 1507 BELVEDERE RD | | | CONT: AUTO BUILDERS | | | TEL: (561)722-3956 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | | | | 2007/09 EXIST BLD CODE 901.3 CHANGE OF OCCUPANCY | | | CLASSIFICATION. WHERE THE OCCUPANCY CLASSIFICATION OF A | | | BUILDING CHANGES, THE PROVISIONS OF SECTIONS 902 | | | THROUGH 912 SHALL APPLY. THIS INCLUDES A CHANGE OF | | | OCCUPANCY CLASSIFICATION WITHIN A GROUP AS WELL AS A | | | CHANGE OF OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A | | | DIFFERENT GROUP. | | | | | | 2007/09 EXIST BLD CODE 905.1 GENERAL. MEANS OF EGRESS | | | IN PORTIONS OF BUILDINGS UNDERGOING A CHANGE OF | | | OCCUPANCY CLASSIFICATION SHALL COMPLY WITH SECTION 912. | | | | | | 2007/09 EXIST BLD CODE 912.4.2 MEANS OF EGRESS FOR | | | CHANGE OF USE TO EQUAL OR LOWER HAZARD CATEGORY. WHEN A | | | CHANGE OF OCCUPANCY CLASSIFICATION IS MADE TO AN EQUAL | | | OR LESSER HAZARD CATEGORY (HIGHER NUMBER) AS SHOWN IN | | | TABLE 912.4, EXISTING ELEMENTS OF THE MEANS OF EGRESS | | | SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 805 FOR | | | THE NEW OCCUPANCY CLASSIFICATION. NEWLY CONSTRUCTED OR | | | CONFIGURED MEANS OF EGRESS SHALL COMPLY WITH THE | | | REQUIREMENTS OF CHAPTER 10 OF THE FLORIDA BUILDING | | | CODE, BUILDING. | | | | | | 1) THE LIFE SAFETY PLAN (COVERSHEET) AND A-1.0 DOES NOT | | | INDICATE ANY RATED CORRIDORS. THE CODE DOES ALLOW FOR | | | SMALL BUSINESS OCCUPANCIES THAT ONLY REQUIRE A SINGLE | | | EXIT NOT TO REQUIRE RATED CORRIDORS AND OR EVEN SINGLE | | | TENANT BUSINESS OCCUPANCIES THAT OCCUPY A WHOLE FLOOR | | | MAY NOT REQUIRE RATED CORRIDORS IF THE DESIGN IS AN | | | OPEN FLOOR PLAN. | | | | | | THE ISSUE IS WITHIN THE CLASSROOM #118 TABLE 1015.1 | | | DOES REQUIRE 2 EXITS FROM THE CLASS ROOM. THE ONE EXIT | | | IS DIRECTLY TO THE EXTERIOR, THE SECOND IS TO WITHIN A | | | EXIT ACCESS COORIDOR. TABLE 1017.1 REQUIRES BUSINESS | | | OCCUPANCIES IN NON-SPRIRKLERED BUILDING HAVING A | | | OCCUPANT LOAD GREATER THAN 30 TO BE ONE-HOUR FIRE RATED | | | CORRIDORS. THIS WOULD MEAN NOT ONLY FIRE RATING OF THE | | | CORRIDOR BUT FIRRE DAMPERS FOR ANY PENETRATIONS OF DUCT | | | WORK WITHIN THE CORRIDOR. | | | | | | 2) SHEET S-1 THERE APPEARS TO BE A DISCREPANCY IN THE | | | IDENTIFYING WIND ZONES ON THE ROOF AND WALL DIAGRAMS, | | | THEY DO NOT MATCH UP WITH THE COLUMN HEADINGS FOR WALLS | | | AND FLAT ROOF ZONES, ONE OF THE TWO IS MIS-LABELED. | | | PLEASE ALSO REVIEW PRESSURES TO VERIFY THE CORRECT | | | PRESSURE FOR COLUMN HEADING. | | | THANK YOU. | | | | | | 3) CHANGE OF OCCUPANCY, PLANS WILL NEED TO BE REVIEWED | | | BY PALM BEACH COUNTY FOR IMPACT FEE ASSESSMENT BEFORE | | | ISSUANCE OF PERMIT. | | | LOCATED AT 2300 N JOG RD 2W01-2W14. WEST PALM BEACH, | | | FL, 33411. | | | | | | | | | JAMES A. WITMER C.B.O. | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561)805-6715 | | | FAX:(561)805-6731 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-08-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-08-08 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-08-08 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-06-23 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-06-23 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-06-22 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-08-18 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-08-18 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-08-18 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2011-08-18 15:47:19 | 1507 BELVEDERE ROAD | | | PERMIT #11060444 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PROVIDE TACTILE SIGNAGE AT ALL EXIT DOORS WITH EXIT | | | SIGNS. | | | | | | THE MAIN ENTRANCE IS PERMITTED TO HAVE AN INTERIOR | | | KEYED DOOR LOCK WITH A READILY VISIBLE SIGN STATING | | | THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING IS | | | OCCUPIED. SIGN LETTERS SHALL BE AT LEAST 1-INCH IN | | | HEIGHT. THE LOCKING DEVICE SHALL BE OF A TYPE THAT IS | | | READILY DISTINGUISHABLE AS LOCKED. | | | | | | IF THE BUILDING WILL BE PROTECTED BY AN AUTOMATIC | | | SPRINKLER SYSTEM, PROVIDE AN EXTERIOR KEY SAFE TO ALLOW | | | EMERGENCY RESPONDERS NON-FORCIBLE ENTRY INTO THE | | | BUILDING DURING NON-BUSINESS HOURS. A KEY SAFE CAN BE | | | ORDERED FROM WWW.KNOXBOX.COM. | | | | | | SHEET SP-1: PROVIDE A MARKED FIRE LANE (STRIPING OR | | | FREESTANDING SIGNS) FOR THE WEST SIDE OF THE BUILDING. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-06-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-06-29 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-06-29 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2011-06-29 11:55:15 | 1507 BELVEDERE ROAD | | | PERMIT #11060444 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | STRUCTURES WITH LIGHT FRAME ROOF TRUSS CONSTRUCTION | | | SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO THE | | | BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS | | | 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED | | | REFLECTIVE COLOR AND BEAR THE LETTER R DESIGNATION PER | | | FLORIDA STATUTE 633.027 AND FLORIDA ADMINISTRATIVE CODE | | | 69A-60.0081. | | | | | | PORTABLE FIRE EXTINGUISHERS SHOWN IN CABINETS SHALL | | | HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE TAGGED BY | | | A LICENSED FIRE EXTINGUISHER COMPANY. | | | | | | PROVIDE BUILDING ADDRESS VISIBLE FROM THE STREET. | | | NUMBERS SHALL BE AT LEAST SIX-INCHES IN HEIGHT AND | | | SHALL CONTRAST THE BACKGROUND. | | | | | | THE OCCUPANCY IS LISTED AS BUSINESS; HOWEVER, THE | | | BUILDING IS FUNCTIONING AS A MULTI-USE (BUSINESS AND | | | ASSEMBLY) OCCUPANCY. THE BUILDING DESIGN SHALL CONFORM | | | TO THE REQUIREMENTS FOR MIXED USE (NON-SEPARATED) OR | | | SEPARATED USE AS INDICATED IN SECTION 6.1.14.2 OF NFPA | | | 101 FLORIDA EDITION 2006. FOR SEPARATED USE, THE | | | ASSEMBLY OCCUPANCY WOULD REQUIRE TWO EXITS AND NEED TO | | | BE SEPARATED FROM BUSINESS USE WITH A ONE HOUR FIRE | | | BARRIER. FOR MIXED USE, THE BUILDING OCCUPANT LOAD | | | EXCEEDS 100 PERSONS AND WOULD REQUIRE EXIT DOORS TO BE | | | EQUIPPED WITH PANIC HARDWARE AND WOULD NOT ALLOW THE | | | USE OF A THUMB TURN LOCK. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-10-26 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2011-10-24 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2011-10-24 15:59:02 | SENT TO JIM'S DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-09-08 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-09-07 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-08-02 |
Time |
17:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-07-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-07-19 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-06-20 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2011-09-08 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-09-08 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-08-17 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2011-09-08 11:42:30 | FEES NOT REQUIRED, SEE RECEIPT AND COUNTY STAMP ON | | | PLAN, '0' DUE. | | | L.MARTINEZ | | 2011-08-17 13:09:31 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
N |
Date |
2011-09-08 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-09-06 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-09-06 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2011-09-07 11:53:17 | SEE NOTES UNDER SEPARATE LANDSCAPE PERMIT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-08-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-08-12 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-08-12 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-07-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-07-19 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-07-14 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2011-07-19 07:30:47 | PLAN DENIED | | | AHU- A1 | | | REFER TO SECTION 606.2.1 SUPPLY SYSTEM AND SECTION | | | 606.3 INSTALLATION. | | | 2007 FBC (M) | | | REFER TO SECTION 13-409.AB.3.3 SHUTOFF DAMPER | | | CONTROLS.2007 FBC. | | | AHU- 1B | | | REFER TO SECTION 607.7 FLEX DUCT PASSING THROUGH A 1 | | | HR. RATED PARTITION. | | | ROOM 117 TO ROOM 116. | | | REFER TO SECTION 606.2.1 SUPPLY SYSTEM AND 606.3 | | | INSTALLATION | | | 2007 FBC (M) | | | AHU- 2 | | | REFER TO SECTION 601.4 BALANCED RETURN AIR. FOR OFFICE | | | 104. | | | 2007 FBC(M) | | | AHU-4 | | | REFER TO SECTION 601.4 BALANCED RETURN AIR. ROOM 101 | | | RECEPTION. | | | 2007 FBC (M) | | | SEE BUILDING REVIEW NOTES ON CHANGE OF OCCUPANCY, RATED | | | CORRIDORS | | | PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-08-22 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-08-22 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-08-22 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2011-08-22 10:38:10 | RE-STAMP |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2011-07-13 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-07-13 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-07-13 |
Time |
09:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2011-09-07 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-09-07 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-09-07 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2011-09-07 11:54:00 | PASSED PENDING APPLICATION FOR LANDSCAPE PERMIT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2011-09-06 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-09-06 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-09-06 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2011-09-06 12:01:44 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | THE DESIGNATED AREA FOR LOADING BLOCKS A PORTION OF THE | | | TWO-WAY DRIVE AISLE. SO THE LOADING AREA MUST BE | | | RELOCATED ON THE PROPERTY. IN ADDITION, THE DESIGNATED | | | LOADING AREA MUST BE CLEARLY MARKED WITHIN THE PARKING | | | LOT. | | | | | | THE RESPONSE TO THIS COMMENT MAY BE ADDRESSED ON THE | | | LANDSCAPE PLAN. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-07-09 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-07-09 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-07-09 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2011-07-09 14:59:01 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | THE VALUE OF THE RENOVATION EXCEEDS 50% OF THE VALUE OF | | | THE PROPERTY. PLEASE SUBMIT A SIGNED AND SEALED | | | LANDSCAPE PLAN IN ACCORDANCE WITH ARTICLE XIV OF THE | | | ZONING CODE. A 10'X25' LOADING SPACE MUST BE SHOWN ON | | | THE SITE PLAN. THE MECHANICAL EQUIPMENT MUST BE | | | SCREENED. PLEASE INDICATE PLANT MATERIALS USED FOR | | | SCREENING ON THE LANDSCAPE PLAN. | | | | | | SEPARATE PERMITS WILL BE REQUIRED FOR SIGNAGE AND ANY | | | IMPROVEMENTS TO THE PARKING LOT. | | | | | | YOUR RESUBMISSION MAY GENERATE ADDITIONAL COMMENTS. | | | | | | |
|
|