| Plan Review Stops For Permit 11060309 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-07-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-07-14 |
Time |
13:12 |
Rev Time |
1.20 |
| Received By |
jwitmer |
Date |
2011-07-14 |
Time |
11:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-06-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-06-20 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2011-06-20 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2011-06-20 15:09:53 | BUILDING PLAN REVIEW | | | PERMIT: 11060309 | | | ADD: 2201 45 TH ST | | | CONT: WESTBROOKE | | | TEL: (561)239-7133 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) THERE SEEMS TO BE A DISCREPANCY IN THE USE OF DOOR | | | SYMBOLS FOUND ON SHEET A-001, THE DIFFERENCE BETWEEN | | | EXISSTING DOORS AND NEW DOORS AS FOUND | | | ON SHEET A-112. THE DOORS IN QUESTION WILL BE DOOR 101 | | | THE ELECTRIC ROOM WHICH IS INDICATED AS 1 HOUR WALL | | | RATINGS BUT THE DOOR DOES NOT SHOW ANY FIRE RATING ON | | | SHEET A303. | | | | | | 2) THE ROOM 103 IS INDICATED AS 1 HR WALLS BUT THE DOOR | | | SCHEDULE FOUND ON A-303 THE FIRE RATING FOR DOOR 103 IS | | | BLANK. THE SAME ISSUE WITH DOOR 104A. | | | | | | 3) ROOM 111 SOILED HOLD WALL TYPE IS INDICATED AS 16-B | | | BUT NO WALL TYPE IS FOUND ON SHEET A-300 . | | | | | | 4) ROOM 126 IS VINDICATED AS A 1HOUR RATED WALL SYSTEM, | | | THE DOOR SYMBOL INDICATES THIS TO BE A NEW DOOR WHERE | | | AS THE DOOR SCHEDULE INDICATES THIS TO BE EXISTING, | | | DISCREPANCY NO FIRE RATING IS PROVIDED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-06-22 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-06-22 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-06-21 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-07-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-07-22 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-07-22 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-07-05 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-06-29 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-06-29 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2011-07-05 10:16:11 | 2201 45TH STREET - CATH LAB | | | PERMIT #11060309 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | REFER TO BUILDING DEPT REVIEW COMMENTS. DRAWINGS WILL | | | BE STAMPED, INITIALED, AND DATED BY THE FIRE DEPARTMENT | | | AFTER ALL PLAN REVIEWER COMMENTS HAVE BEEN SATISFIED. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-07-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-07-22 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-07-14 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2011-07-14 08:57:30 | SENT TO SHELF C25 FOR BUILDING AND FIRE REVIEW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-07-06 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-06-30 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-06-15 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2011-06-15 10:38:36 | SENT TO B8 SHELF FOR REVIEW. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2011-06-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-06-30 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-06-30 |
Time |
06:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
1 |
Status |
P |
Date |
2011-06-27 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-06-27 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-06-27 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2011-06-27 11:14:40 | MED GAS PERMIT IS REQUIRED BEFORE ANY MED GAS DEMO WORK | | | IS STARTED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2011-06-27 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-06-27 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-06-23 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2011-06-27 10:59:13 | ****PROVISO**** | | | 1. THE DRIP TROUGH SHOWN ON P2.02 IS SHOWN TURNED DOWN | | | OVER A PATIENT PREP HAND WASH. THIS LINE SHOULD | | | TERMINATE OVER THE SOILED SINK OR EXISTING JANITORS | | | SINK. | | | | | | 2. MED GAS PERMIT IS REQUIRED BEFORE ANY MED GAS DEMO | | | WORK IS STARTED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2011-06-29 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-06-29 |
Time |
11:48 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2011-06-29 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2011-06-29 11:48:55 | INTERIOR WORK ONLY. LESS THEN 50% VALUE AND CSPD HAS | | | APPROVED LANDSCAPE PLAN MEETING CURRENT ZLDRS. |
|
|