| 2011-06-16 13:26:12 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW |
| | CHECKLIST. |
| | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| | |
| | 1- MISSING STRUCTURAL DRAWINGS S1 AND S2 THAT ARE |
| | LISTED ON THE LIST OF DRAWINGS ON TITLE SHEET T. SUBMIT |
| | THIS DRAWINGS FOR REVIEW. |
| | ***NOTE: ACCORDING TO 2009 REVISIONS SEC. R301.2.1.4.3 |
| | THIS BUILDING IS LOCATED ON EXPOSURE "C". STRUCTURAL |
| | DRAWINGS TO REFLECT THIS DESIGN CONSIDERATION. |
| | |
| | 2- SPECIFY CARBON MONOXIDE ALARMS ON DRAWINGS AS |
| | REQUIRED BY SEC. R313.4. |
| | |
| | 3- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 |
| | FLORIDA STATUTES. |
| | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK |
| | UP. |
| | |
| | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) EXTERIOR DOOR AS SHOWN ONPLANS. |
| | |
| | B) CASEMENT WINDOWS AS SHOWN ON PLANS. |
| | |
| | C) PRECAST LINTELS IF SPECIFIED ON STRUCTURAL PLANS. |
| | |
| | 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS. SEC. |
| | 106.3.3 CITY AMENDMENTS TO FBC. |
| | |
| | 6- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS |
| | FOR NEW PULL DOWN ATTIC ACCESSS. ALSO, SPECIFY ATTIC |
| | ACCES SIZE. ***NOTE: TAKE INTO CONSIDERATION THAT |
| | EXISTING TRUSSES MAY NEED TO BE CUT TO ALLOW FOR THE |
| | NEW OPENING. PROVIDE DETAIL/SPECS SHOWING HOW |
| | REINFORCING EXISTING TRUSSES TO KEEP TRUSSES |
| | STRUCTURALLY SOUND. SEC. 106.1.2 CITY AMENDMENTS TO |
| | FBC. |
| | |
| | 7- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| | N1100.0 |
| | |
| | 8- SHEET T: A) REVISE PLUMBING NOTE #2. SEE SEC. |
| | P3005.3 FOR MIN. REQUIRED SLOPE AND REVISE AS REQUIRED. |
| | |
| | B) SPECIFY CURRENT BUILDING CODE AND REVISIONS. 2007 |
| | FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| | |
| | 9- SHEET A2: REVISE DESIGN PRESSURES FOR NEW SWING DOOR |
| | AND NEW CASEMENT WINDOWS. SEC. R301. NEED DESIGN |
| | PRESSURES FOR EXP[OSURE "C". COORDINATE WITH STRUCTURAL |
| | DRAWINGS S1 & S2 AND WITH ITEM #1 ABOVE. |
| | |