Plan Review Details - Permit 11060272
Plan Review Stops For Permit 11060272
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-07-08 Cont ID  
Sent By rmcdouga Date 2011-07-08 Time 09:31 Rev Time 0.00
Received By rmcdouga Date 2011-07-08 Time 07:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-06-17 Cont ID  
Sent By rmcdouga Date 2011-06-17 Time 08:04 Rev Time 0.00
Received By rmcdouga Date 2011-06-17 Time 08:04 Sent To  
Notes
2011-06-17 08:04:522007 FBC W/2009 REVISIONS
  
 1) THE NEW BATHROOM IS REQUIRED TO HAVE MECHANICAL
 VENTILATION PER FBC R303.3. SHOW COMPLIANCE ON THE
 PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-07-08 Cont ID  
Sent By rmcdouga Date 2011-07-08 Time 09:31 Rev Time 0.00
Received By rmcdouga Date 2011-07-08 Time 09:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-06-17 Cont ID  
Sent By rmcdouga Date 2011-06-17 Time 08:19 Rev Time 0.00
Received By rmcdouga Date 2011-06-17 Time 08:19 Sent To  
Notes
2011-06-17 08:38:072007 FBC W/2009 REVISIONS
 2008 NEC
  
 DENIED BY ELECTRIC
  
 1) SHOW LOCATIONS OF RECEPTACLES (NEC 210.52), LIGHTING
 OUTLETS AND WALL SWITCHES (NEC 210.70).
  
 2) SHOW COMPLIANCE WITH NEC 406.11 FOR TAMPER RESISTANT
 RECEPTACLES AND NEC 210.8 FOR GFCI PROTECTION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2011-06-16 Cont ID  
Sent By jpapa Date 2011-06-16 Time 16:23 Rev Time 0.00
Received By jpapa Date 2011-06-16 Time 16:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-07-08 Cont ID  
Sent By jwitmer Date 2011-06-30 Time 16:07 Rev Time 0.00
Received By rmcdouga Date 2011-06-30 Time 16:06 Sent To  
Notes
2011-06-30 16:07:56INCOMING SENT TO R MC DOUGAL DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-06-17 Cont ID  
Sent By rmcdouga Date 2011-06-17 Time 08:19 Rev Time 0.00
Received By rmcdouga Date 2011-06-14 Time 15:32 Sent To  
Notes
2011-06-14 15:32:34SENT TO R4 FOR REVIEW.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2011-06-17 Cont ID  
Sent By rmcdouga Date 2011-06-17 Time 07:53 Rev Time 0.00
Received By rmcdouga Date 2011-06-17 Time 07:53 Sent To  
Notes
2011-06-17 08:04:08NO MECHANICAL WORK SHOWN ON PLANS AND NO MECHANICAL
 PERMIT APPLIED FOR.

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-07-08 Cont ID  
Sent By rmcdouga Date 2011-07-08 Time 09:31 Rev Time 0.00
Received By rmcdouga Date 2011-07-08 Time 09:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-06-17 Cont ID  
Sent By rmcdouga Date 2011-06-17 Time 07:10 Rev Time 0.00
Received By rmcdouga Date 2011-06-17 Time 07:10 Sent To  
Notes
2011-06-17 07:41:33DENIED BY PLUMBING
  
 1) SHOWER IS NOT PROPERLY VENTED. THE TRAP SEAL OF THE
 WATER CLOSET WILL BE SUBJECTED TO PNEUMATIC PRESSURE IN
 VIOLATION OF FBCR P3101.2.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2011-06-16 Cont ID  
Sent By jpapa Date 2011-06-16 Time 16:24 Rev Time 0.25
Received By jpapa Date 2011-06-16 Time 16:24 Sent To  
Notes
***NONE***