Plan Review Details - Permit 11060020
Plan Review Stops For Permit 11060020
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2011-08-05 Cont ID  
Sent By jgomez Date 2011-08-05 Time 10:37 Rev Time 0.00
Received By jgomez Date 2011-08-05 Time 10:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-07-18 Cont ID  
Sent By jgomez Date 2011-07-18 Time 09:16 Rev Time 0.00
Received By jgomez Date 2011-07-18 Time 09:16 Sent To  
Notes
2011-07-18 09:21:12BUILDING REVIEW APPROVED WITH PROVISO PER CONVERSATION
 WITH CONTRACTOR:
  
 1- ENGINEER LETTER FROM HUSTAD STRUCTURAL ENGINEERING
 NEEDS TO BE SIGNED AND SEALED BY THE ENGINEER AS
 REQUIRED BY CHAPTER 471 FLORIDA STATUTES. PROVIDE 2
 COPIES.
  
 2- A) FLAT ROOF NOA 07-1203.01 SUBMITTED WAS
 SUPERSEDED. PROVIDE 2 CURRENT NOA'S.
  
 B) ENGINEER DOING THE RAS 117 CALCULATIONS IS
 REFERENCING THIS NOA. ENGINEER NEEDS TO REVISE THE RAS
 117 CALCULATIONS USING A CURRENT NOA.
 PROVIDE 2 COPIES OF RAS 117 CALCULATIONS WITH ORIGINAL
 SEAL AND SIGNATURE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-07-18 Cont ID  
Sent By jgomez Date 2011-07-18 Time 08:42 Rev Time 0.00
Received By jgomez Date 2011-07-18 Time 08:22 Sent To  
Notes
2011-07-18 08:52:07RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW SECOND
 CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- ENGINEER LETTER FROM HUSTAD STRUCTURAL ENGINEERING
 NEEDS TO BE SIGNED AND SEALED BY THE ENGINEER AS
 REQUIRED BY CHAPTER 471 FLORIDA STATUTES. LETTER
 PROVIDED IS NOT SIGNED AND SEALED.
 PROVIDE 2 COPIES WITH ORIGINAL SEAL AND SIGNATURE. ONLY
 ONE COPY WITHOUT SEAL AND SIGNATURE WAS SUBMITTED.
  
 2- FLAT ROOF NOA 07-1203.01 SUBMITTED WAS SUPERSEDED.
 (REPEAT COMMENT). ENGINEER DOING THE RAS 117
 CALCULATIONS IS REFERENCING THIS NOA. ENGINEER NEEDS TO
 REVISE THE RAS 117 CALCULATIONS USING A CURRENT NOA.
 PROVIDE 2 COPIES OF RAS 117 CALCULATIONS ONLY ONE WAS
 PROVIDED.
  
 3- PROVIDE TWO COPIES OF POLYFOAM NOA. ONLY ONE COPY
 WAS SUBMITTED.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-06-02 Cont ID  
Sent By jgomez Date 2011-06-02 Time 08:42 Rev Time 0.00
Received By jgomez Date 2011-06-02 Time 08:25 Sent To  
Notes
2011-06-02 08:54:09RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- ACCORDING TO CITY RECORDS PERMIT #99081115 AND
 PROPERTY APPRAISAL RECORDS THIS HOUSE ROOF COVER IS
 ASPHALT SHINGLES. PROPOSED ROOF COVER IS CONCRETE TILE.
 NEED TO PROVIDE ENGINEERING SHOWING THAT THE EXISTING
 STRUCTURE IS DESIGNED TO RESIST THE ADDITIONAL LOAD.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC.
  
 2- FLAT ROOF PRODUCT APPROVAL SUBMITTED:
 A) NOA 07-1203.01 SUBMITTED WAS SUPERSEDED BY
 MIAMI-DADE. VISIT MIAMI-DADE WEBSITE DOWNLOAD CURRENT
 NOA AND RESUBMIT.
  
 B) CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO
 BE INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES OF SEC. R301.
  
 C) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS
 REQUIRED BY GENERAL LIMITATION # 7 ON LAST PAGE OF NOA.
 ***NOTE: ASSEMBLIES THAT ARE LIMITED BY GENERAL
 LIMITATION #9 CAN'T BE USED IN THIS BUILDING BECAUSE
 THEY DON'T MEET THE DESIGN PRESSURES REQUIRED BY SEC.
 R301.
  
 D) DESIGN PROFESSIONAL DOING THE RAS 117 CALCULATIONS
 TO TAKE INTO CONSIDERATION THAT ACCORDING TO THE 2009
 REVISIONS SEC. R301.2.1.4.3 THS BUILDING IS LOCATED ON
 EXPOSURE "C".
  
 3- CONCRETE TILE NOA 07-1018.08 SUBMITTED WAS
 SUPERSEDED BY MIAMI-DADE. VISIT MIAMI-DADE WEBSITE
 DOWNLOAD CURRENT NOA AND RESUBMIT.
  
 4- POLYFOAM NOA 06-0201.02 SUBMITTED EXPIRED ON
 05/10/11. PROVIDE CURRENT NOA.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2011-06-01 Cont ID  
Sent By jpapa Date 2011-06-01 Time 13:07 Rev Time 0.00
Received By jpapa Date 2011-06-01 Time 13:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2011-08-05 Cont ID  
Sent By jgomez Date 2011-08-05 Time 10:36 Rev Time 0.00
Received By jgomez Date 2011-08-05 Time 10:36 Sent To  
Notes
2011-08-05 10:36:50PACKAGE SUBMITTAL TO ADDRESS PROVISO. JG.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-07-18 Cont ID  
Sent By jgomez Date 2011-07-18 Time 09:07 Rev Time 0.00
Received By jgomez Date 2011-07-18 Time 09:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-07-18 Cont ID  
Sent By jgomez Date 2011-07-18 Time 08:22 Rev Time 0.00
Received By jgomez Date 2011-07-18 Time 08:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-06-02 Cont ID  
Sent By jgomez Date 2011-06-02 Time 08:25 Rev Time 0.00
Received By jgomez Date 2011-06-02 Time 08:25 Sent To  
Notes
***NONE***