Plan Review Details - Permit 11050785
Plan Review Stops For Permit 11050785
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-06-29 Cont ID  
Sent By jwitmer Date 2011-06-29 Time 13:41 Rev Time 0.50
Received By jwitmer Date 2011-06-29 Time 13:41 Sent To  
Notes
2011-06-29 13:42:40RELOCATE HISTORIC BUILDING FROM 1901 S FLAGLER TO 1910
 S OLIVE AVE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-06-22 Cont ID  
Sent By jwitmer Date 2011-06-22 Time 08:47 Rev Time 0.99
Received By jwitmer Date 2011-06-22 Time 08:47 Sent To  
Notes
2011-06-22 09:06:04BUILDING PLAN REVIEW
 PERMIT: 11050785
 ADD: ????????
 CONT:KAUFMAN & LYNN CONSTRUCTION
 TEL: (561) 361-6700
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE THE BUILDING DEPARTMENT WITH AN UPDATED
 CONTRACTOR OF RECORD, I HAD CONTACTED KAUFMAN & LYNN
 WITH QUESTIONS ONLY TO FIND OUT THEY ARE NO LONGER THE
 CONTRACTOR OF RECORD.
  
 2) PLEAS PROVIDE A KEY PLAN OF WHAT BUILDINGS ARE BEING
 MOVED TO WHICH SITES DO NOT USE ADRESES SINCE THE NEW
 ADRESES MAY CHANGE THEY WIL BE ASIGNED BY THE CITY.
  
 3) THE PLANS ARE NOT CLEAR AS TO WHAT WORK IS TO BE
 COVERED UNDER THIS PERMIT, (3) ADRESSES ARE INDICATED
 ON THE PERMIT APLICATION?
  
 4) STRUCTURAL SHET S-1 DOES NOT HAVE THE ADDRESS OF
 WHERE THE STRUCTURE IS BEING MOVED TO, THIS WOULD BE
 WHERE THE NEW FOUNDATION WIL BE LOCATED.
  
 5) S-1,PLEASE REVIEW THE NEW LOCATION WHERE THIS
 BUILDING IS BEING LOCATED, THE FOUNDATION NEDS TO
 REFLECT THIS LOCATION BEING LOCATED WITHIN A "C"
 COASTAL EXPOSURE PLEASE UPDATE PLANS.
 1609.4.3 EXPOSURE CATEGORIES. AN EXPOSURE CATEGORY
 SHALL BE DETERMINED IN ACCORDANCE WITH THE FOLLOWING:
  
 EXPOSURE C. OPEN TERRAIN WITH SCATTERED OBSTRUCTIONS,
 INCLUDING SURFACE UNDULATIONS OR OTHER IRREGULARITIES,
 HAVING HEIGHTS GENERALLY LESS THAN 30 FEET (9144 MM)
 EXTENDING MORE THAN 1,500 FEET (457.2 M) FROM THE
 BUILDING SITE IN ANY QUADRANT. THIS EXPOSURE SHALL ALSO
 APPLY TO ANY BUILDING LOCATED WITHIN EXPOSURE B-TYPE
 TERRAIN WHERE THE BUILDING IS WITHIN 100 FEET
 HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF EXPOSURE
 C-TYPE TERRAIN THAT EXTENDS MORE THAN 600 FEET (182.9
 M) AND WIDTH GREATER THAN 150 FT. IN THE UPWIND
 DIRECTION. SHORT-TERM (LESS THAN TWO YEAR) CHANGES IN
 THE PRE-EXISTING TERRAIN EXPOSURE, FOR THE PURPOSES OF
 DEVELOPMENT, SHALL NOT BE CONSIDERED OPEN FIELDS. WHERE
 DEVELOPMENT BUILDOUT WILL OCCUR WITHIN THREE YEARS AND
 THE RESULTANT CONDITION WILL MEET THE DEFINITION OF
 EXPOSURE B, EXPOSURE B SHALL BE REGULATING FOR THE
 PURPOSE OF PERMITTING. THIS CATEGORY INCLUDES FLAT OPEN
 COUNTRY, GRASSLANDS AND OCEAN OR GULF SHORELINES AND
 SHALL EXTEND DOWNWIND FOR A DISTANCE OF 1500 FEET. FOR
 BUILDINGS LOCATED WITHIN A DISTANCE OF 600 FEET OF
 INLAND BODIES OF WATER THAT PRESENT A FETCH OF 1 MILE
 (1.61 KM) OR MORE OR INLAND WATERWAYS OR RIVERS WITH A
 WIDTH OF 1 MILE (1.61 KM) OR MORE ROOF SHEATHING UPLIFT
 AND ROOF-TO-WALL UPLIFT LOADS SHALL BE INCREASED BY 20
 PERCENT.
  
 6) S-1 JURISDICTION IS NOT ST. LUCIE CTY, AND PROJECT
 NAME.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-06-21 Cont ID  
Sent By rlecky Date 2011-06-21 Time 11:12 Rev Time 0.00
Received By rlecky Date 2011-06-21 Time 10:32 Sent To  
Notes
2011-06-21 11:12:57PROVISO:
 PROVIDE AN ENGINEERED DETAIL FOR THE FOUNDATION AND
 COMPLETE LIGHT POLE MOUNTED ASSEMBLY WHICH PROVIDES A
 MINIMUM WIND LOAD CAPABILITY OF 140 MPH.
  
 VERIFY THE ELECTRICAL SYSTEM FOR THE RELOCATED BUILDING
 IS SUITABLE FOR THE INTENDED USE PRIOR TO OCCUPANCY.
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2011-06-29 Cont ID  
Sent By mgonzale Date 2011-06-29 Time   Rev Time 1.00
Received By mgonzale Date 2011-06-29 Time   Sent To  
Notes
2011-06-29 12:45:25BUILDING LOCATION DOES NOT POSE A CONFLICT FOR CITY OF
 WEST PALM BEACH PUBLIC UTILITIES.
  
 CALL 811 BEFORE DIGG.
  
 ROW PERMIT MAY BE REQUIRED FOR MAKING USE OF THE ROW TO
 STAGE AND/OR MOVE EQUIPMENT.
 FOR MORE ON MAKING USE OF ROW PLEASE FEEL FREE TO
 CONTACT DEAN LAUDERMILK CITY OF WPB RIGH-OF-WAY.
  
 MANUEL JULIAN GONZALEZ
 CSD ENGINEERING
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-06-07 Cont ID  
Sent By wjolin Date 2011-06-07 Time 16:14 Rev Time 0.00
Received By wjolin Date 2011-06-07 Time 16:11 Sent To  
Notes
2011-06-07 16:14:091901 SOUTH FLAGLER DRIVE
 PERMIT #11050785
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVIDE A KNOX KEY SWITCH TO ALLOW EMERGENCY RESPONDERS
 ACCESS THROUGH THE SECURITY GATE. KEY SWITCH CAN BE
 ORDERED FROM WWW.KNOXBOX.COM.
  
 FIRE DEPARTMENT ACCESS ROADS SHALL HAVE A SURFACE
 DESIGNED TO ACCOMMODATE FIRE APPARATUS WEIGHING AT
 LEAST 32 TONS.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2011-06-30 Cont ID  
Sent By fmittner Date 2011-06-30 Time 11:33 Rev Time 0.00
Received By fmittner Date 2011-06-30 Time 11:33 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2011-06-20 Cont ID  
Sent By fmittner Date 2011-06-20 Time 14:13 Rev Time 0.00
Received By fmittner Date 2011-06-20 Time 14:13 Sent To  
Notes
2011-06-20 14:15:36RETURNING PLANS TO C-16 FOR REVIEW BY OTHERS.
2011-06-20 14:15:12WAITING ON REVISION OF CONDITION BY CITY COMMISSION
 JULY 11TH.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-07-15 Cont ID  
Sent By lmartine Date 2011-07-12 Time 15:44 Rev Time 0.00
Received By lmartine Date 2011-06-27 Time 16:27 Sent To  
Notes
2011-06-27 16:27:29SENT TO C10 FOR REVIEW BY BUILDING, HISTORIC & ZONING.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-07-15 Cont ID  
Sent By lmartine Date 2011-06-27 Time 15:42 Rev Time 0.00
Received By lmartine Date 2011-06-01 Time 11:26 Sent To  
Notes
2011-06-01 11:27:04SENT TO C16.

Review Stop L LANDSCAPING
Rev No 1 Status N Date 2011-06-13 Cont ID  
Sent By rkussner Date 2011-06-13 Time 14:34 Rev Time 0.00
Received By rkussner Date 2011-06-13 Time 14:34 Sent To  
Notes
2011-06-13 14:38:47***LANDSCAPE REVEIW NOT REQUIRED***
  
 PLEASE REFER TO PERMIT #11050786 FOR LANDSCAPE PERMIT
 AND PLANS.--RAK

Review Stop P PLUMBING
Rev No 1 Status N Date 2011-06-21 Cont ID  
Sent By lwagner Date 2011-06-21 Time 13:55 Rev Time 0.00
Received By lwagner Date 2011-06-21 Time 13:39 Sent To  
Notes
2011-06-21 14:00:50NO PLUMBING SHOWN AT THIS TIME. PLUMBING PERMIT
 REQUIRED.
 IRRIGATION TO BE SEPARATE APPLICATION, DRAWING, AND
 PERMIT.

Review Stop Z ZONING
Rev No 2 Status P Date 2011-07-12 Cont ID  
Sent By fmittner Date 2011-07-12 Time 15:39 Rev Time 0.00
Received By fmittner Date 2011-07-12 Time 15:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2011-06-09 Cont ID  
Sent By eschneid Date 2011-06-09 Time 09:44 Rev Time 0.50
Received By eschneid Date 2011-06-09 Time 09:44 Sent To  
Notes
2011-06-09 09:57:51FAILED
  
 1) PER ORD. NO. 4303-10, THE BUILDING MAY NOT BE
 RELOCATED UNTIL DEVELOPMENT IS COMMENCED ON EITHER THE
 ACADEMIC OR EDUCATIONAL BUILDING. PBDA HAS REQUESTED AN
 AMENDMENT TO THIS CONDITION TO ALLOW THE RELOCATION
 WITHOUT REQUIRING THE COMMENCEMENT OF DEVELOPMENT ON
 THE OTHER BUILDINGS. THE CITY COMMISSION IS SCHEDULED
 TO HAVE THE 2ND READING ON THE AMENDED ORDINANCE ON
 JULY 11. STAFF CAN NOT APPROVE THE RELOCATION PERMIT
 UNTIL THE ORDINANCE PASSES.
  
 2) THE RELOCATION CONFORMS TO THE LOCATION APPROVED AS
 PART OF ORD. NO. 4303-10. THE CIVIL PLANS AND SHEET
 GD1.2 DO NOT SHOW THE CORNER SIDE SETBACK DIMENSION.
 THE CORNER SIDE SETBACK SHALL BE 17.8 FEET AS STATED ON
 THE MASTER PLAN SHEET MP 1.
  
 3) PLEASE NOTE THAT THE PLANS SUBMITTED WITH THE PERMIT
 INCLUDE PLANS THAT ARE NOT DIRECTLY RELATED TO THE
 RELOCATION.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved