Plan Review Details - Permit 11050735
| Plan Review Stops For Permit 11050735 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-06-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-06-23 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-06-23 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-06-10 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-06-10 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2011-06-10 13:15:47 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. SEE OPENING 2 (AND ALL OTHER OPENINGS OVER 5' WHICH | | | PROPOSE A SILL INSTALLATION). 9.5" ANCHOR SPACING IS | | | HIGHLIGHTED ON THE PRODUCT APPROVAL, BUT 10" IS | | | PROPOSED FOR ANCHOR SPACING. PLEASE REVISE INSTALLATION | | | SCHEDULE TO BE COMPLIANT WITH THE REQUIREMENTS OF THE | | | PRODUCT APPROVAL. | | | | | | 2. OPENING 10, BOTTOM ANCHOR SPACING, WAS LEFT BLANK. | | | PLEASE REVISE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-06-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-06-01 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-06-01 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2011-06-01 09:44:15 | ****CORRECTIONS**** | | | REVISED 6/3 | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. APPLICATION IS FOR ACCORDION SHUTTERS, BUT | | | INSTALLATION SCHEDULE IS FOR HORIZONTAL INSTALLATION | | | (SEE 7TH COLUMN ON INSTALLATION SCHEDULE FORM COMPLETED | | | BY CONTRACTOR). SPANS DO APPEAR, HOWEVER, TO CORRELATE | | | WITH THE VERTICAL DIMENSION. | | | | | | 2. THE "SHUTTER MOUNTING CONNECTION TYPE" SHOULD STATE | | | WHICH CONNECTION TYPES ARE PROPSED. SEE SHEET 10; | | | NAMING CONVENTION FOR THIS PRODUCT APPROVAL WOULD BE | | | WALL MOUNT 1 (W/1"), WALL MOUNT 3. | | | | | | 3. PLEASE NOTE THAT THE SUBSTRATE ON THE INSTALLATION | | | SCHEDULE IS BLOCK, BUT WALL MOUNT 1 (HIGHLIGHTED) | | | REQUIRES A CONCRETE SUBSTRATE. CBS HOUSES TYPICALLY | | | HAVE A POURED CONCRETE TOP SUBSTRATE, BLOCK BOTTOM | | | SUBSTRATE. | | | | | | 4. SPANS NOT CORRECT. SPAN CANNOT BE THE SAME AS | | | OPENING SIZE DUE TO EDGE DISTANCE. SPAN SHOULD EQUAL | | | BLADE LENGTH. | | | | | | 5 PLEASE PROVIDE TWO SETS WHEN RESUBMITTING. DUE TO | | | WORK LOAD, DECREASED STAFF, AND INCREASED OFFICE | | | DUTIES, IT IS VERY DIFFICULT TO PROVIDE CLERICAL | | | SERVICES. FAILURE TO PROVIDE ALL DOCUMENTS REQUIRED MAY | | | RESULT IN PERMIT ISSUANCE DELAYS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-06-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-06-23 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-06-20 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2011-06-20 08:00:27 | TO SH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-06-10 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-06-09 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2011-06-09 10:49:26 | GAVE TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-06-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-06-01 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-05-26 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2011-05-26 08:51:47 | MISC. 1 |
|
|
|