Plan Review Details - Permit 11050596
| Plan Review Stops For Permit 11050596 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2012-06-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-06-25 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-06-25 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2012-06-25 16:51:38 | BUILDING PLAN REVIEW | | | PERMIT: 11050596 | | | ADD: 114 S OLIVE AVE | | | CONT: LAKESIDE CONTRACTING CORP | | | TEL: (954)553-8398 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | 2007/09 FLORIDA EXISTING BUILDING CODE W/ SUPPLEMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 4TH REVIEW | | | JUNE 25,/ 2012 | | | ACTION: DENIED | | | | | | NOTE: WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY | | | MAKING TWO COMPLETE SETS OF PLANS. PLANS WERE SUBMITTED | | | IN INCOMPLETE SETS MAKING A PLAN REVIEW OF 4 PARTIAL | | | SETS VERY TIME CONSUMING AND WHAT STILL LOOKS OR | | | APPEARS TO BE INCOMPLETE PLANS! A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 1) COMPLIED. | | | | | | 2) 4TH REQUEST, NOT FOUND ON EITHER THE COVER SHEET NOR | | | LS-01. WHAT WAS THE LAST KNOWN USE FOR THIS BUILDING, | | | IS THIS A CHANGE OF OCCUPANCY? THE PLANS DO NOT | | | REFERENCE THE FLORIDA EXISTING BUILDING CODE AND TO | | | WHICH TYPE OF COMPLIANCE METHOD THE PLANS WERE DESIGNED | | | TOO? FL EXST BLDG CODE 101.5 (.1-.3).RESPONCE INDICATES | | | THE LAST KNOWN USE A RESTARAUNT. THE PALM BEACH COUNTY | | | IMPACT FEE OFFICE INDICATES THE LAST KNOWN USE TO BE A | | | BUSINESS OFFICE NOT A RESTARAUNT, THIS TRIGGERS THE | | | 2007 EXISTING BUILDING CODE CHAPTER 9 SECTION 901.3AND | | | THE PROVISIONS OF 902 THROUGH 912 OF THE EXISTING | | | BUILDING CODE SHALL APPLY. | | | | | | 3A) FOURTH REQUEST, PLEASE REFER TO THE 2007 FBC-B FOR | | | BUILDING TYPE, NOTE THE 2007FBC-B 603.1.3 REQUIRES ALL | | | ROOF CONSTRUCTION GIRDERS, JOIST, TRUSSES AND DECKING | | | ARE TO BE FIRE RETARDANT TREATED WOOD. SHEET S-5 | | | INDICATES THE EXISTING 2X6 ROOF FRAMING, IS THE | | | EXISTING STRUCTURE TRULY A BUILDING TYPE II-B? PLEASE | | | NOTE THE NEW FRAMING MEMBERS LOCATED ON SHEET S-5 DO | | | NOT INDICATE THE USE OF FIRE RETARDANT TREATED WOOD. | | | SHEET INDICATES THE USE OF EXISTING 2X6 ROOF JOISST AND | | | DECKING TO REMAIN. HOW WILL THIS ISSUE BE | | | RESOLVED??????? PLANS INDICATE THIS IS A TYPE II-B | | | CONSTRUCTION. | | | | | | 3B) COMPLIED. | | | | | | 4-7) COMPLIED. | | | | | | 8) SEMI-COMPLIED, RE | | | | | | THE RESPONCE LETTER INDICATES THE ELEVATOR TO BE A | | | SCHINDLER 3300 MRL ELECTRIC TRACTION ELEVATOR, PLEASE | | | PROVIDE DOCUMENTATION THIS ELEVATOR MEETS THE | | | REQUIREMENTS OF 3001.2 REFERENCED STANDARDS AND | | | ACCESSIBILITY REQUIREMENTS. FORMER COMMENT .PLEASE | | | INDICATE WHERE THE ELEVATOR HYDROLIC PUMP (MACHINE | | | ROOM) WILL BE LOCATED. . PLEASE PROVIDE INFORMATION AS | | | TO SHEET A2-01 & LS-01 WHAT IS THE ROOM # 119 USED FOR | | | IS THIS THE ELEVATOR MACHINE ROOM? IF SO IT NEEDS TO BE | | | RATED AS DOES THE DOOR. | | | | | | | | | THIS REVIEW WILL CONTINUE TUESDAY 6/26/2012 | | | | | | | | | 9) 4TH REQUEST. SHEET A2-01 INDICATES NEW RAISED | | | PLATFORM FLOORING PLEASE PROVIDE SQUARE FOOTAGE OF | | | RAISED PLATFORM FLOORING, PLEASE REVIEW SECTION 2007/09 | | | FBC-B 410.4 FIRE RETARDANT TREATED WOOD REQUIREMENT. | | | THE STRUCTURAL S-4 DATED 01-04-12 STILL INDICATES WOOD | | | FRAMING THE NEW S-2 05/04/12 INDICATES STEEL JOIST, | | | STEEL PAN AND CONCRETE | | | FLOOR FINISH PLEASE REVIEW ALL SHEETS FOR CODE | | | COMPLIANCE. | | | | | | 10) 4TH REQUEST. STRUCTURAL PLANS SUBMITTED S-2 DATED | | | 05-04-12 STILL HAS A DISCREPANCY AS TO WHAT APPEARS TO | | | BE A DOORWAY THAT WOULD LED INTO THE LADIES RESTROOM | | | FROM THE STAIR.DISCREPANCY IN PLANS. 106.1.2 ADDITIONAL | | | INFORMATION REQUIRED. | | | | | | 11) 4TH REQUEST ROOF HATCH PLEASE BE AWARE OF | | | ADDITIONAL INFORMATION REQUIRED, SHEET A2.04 INDICATES | | | THE USE OF A NEW ROOF HATCH ANS DETAIL TO BE LOCATED ON | | | SHEET DETAIL # 11 A7.02. MISSING SHEET A7.02. PLEASE | | | SEE FBC-B 1013.5. & 2007/09 MECH CODE 304.10 FOR GUARD | | | REQUIREMENTS WHEN UNITS ARE WITHIN 10'-0" OF THE ROOF | | | EDGE. | | | | | | ***** NOTED RESPONCE TO KEEP EQUIPMENT 10'-0" AWAY FROM | | | EDGE OF ROOF.***** | | | | | | 11A) GUARDS SHALL BE PROVIDED WHERE APPLIANCES, | | | EQUIPMENT, FANS, ROOF HATCH OPENINGS OR OTHER | | | COMPONENTS THAT REQUIRE SERVICE ARE LOCATED WITHIN 10 | | | FEET (3048 MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING | | | SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN | | | 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE | | | BELOW. THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT | | | THE PASSAGE OF A 21-INCH-DIAMETER (533 MM) SPHERE. THE | | | GUARD SHALL EXTEND NOT LESS THAN 30 INCHES (762 MM) | | | BEYOND EACH END OF SUCH APPLIANCE, EQUIPMENT, FAN OR | | | COMPONENT. | | | | | | 11B) 1013.6 ROOF ACCESS. GUARDS SHALL BE PROVIDED WHERE | | | THE ROOF HATCH OPENING IS LOCATED WITHIN 10 FEET (3048 | | | MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE | | | AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 | | | INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. | | | THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE | | | PASSAGE OF A 21-INCH-DIAMETER (533 MM) SPHERE. | | | | | | | | | 12) COMPLIED. | | | | | | 13) 4TH REQUEST. FL BLD CODE 1609.6.2.2 COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES, 3 IF THRESHOLD OR RESIDENT | | | INSPECTOR OF PRODUCT TESTING REPORTS, MISSING REPORTS | | | ARE AS FOLLOWS: | | | 13A) WINDOWS | | | 13B) EXTERIOR DOORS | | | 13C) ROOF HATCH | | | 13D) A/C PRE-MANUFACTURED STANDS | | | | | | 14) 4TH REQUEST. 106.3.3 PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9B-72 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 15) COMPLIED. | | | | | | 16)4TH REQUEST, SHEET A-2.01 THE PLANS DO NOT PROVIDE | | | ELEVATION CHANGE FROM THE CONCRETE DECK TO FINISHED | | | MAIN SEATING AREA NOT THE VIP PLATFORM. FBC-B 1003.5.2. | | | NOR IS THERE A CUT SECTION THROUGH STAIRS FOR ACCESS TO | | | PLATFROM AREAS. 2007 FBC 1009.3. RISE & RUN. | | | | | | 17) 4TH REQUEST. RESPONCE COMMENTS INDICATE STAIR | | | DETAILS FOR STAIR # 2 ARE TO BE FOUND ON A4-03, A4-04 | | | AND DETAIL #4 ON SHEET A4-06. | | | THE NUMBERED SHEETS STATED IN RESPONCE WERE NOT FOUND | | | IN THE FOURTH SUBMITAL, NOR ON SHEETS DATED 2/16/12 NOR | | | 1/06/12/ | | | SHEET A-5.02 STAIRWELL # 2. NO STRUCTURAL PLANS WERE | | | SUBMITTED THE TYPE OF MATEIAL FOR STAIR CONSTRUCTION IS | | | NOT PROVIDED 2007/09 FBC-B 1009.5 NOR IS THE RISE NOR | | | RUN OF THE STAIRSFBC-B 1009.3. | | | | | | 18) 4TH REVIEW NO NEW LS02 SHEETS SUBMITTED . SHEET | | | LS-02 MEZZANINE RESTROOMS PLEASE SEE 11-4,11-4.1.3(11) | | | IF TOILET ROOMS ARE PROVIDED, THEN EACH PUBLIC & COMMON | | | USE TOILET ROOM SHALL COMPLY WITH 11-4.22. | | | PLEASE REVIEW 11-4.22(1) DOORS SHALL NOT SWING INTO THE | | | CLEAR FLOOR SPACE REQUIRED FOR ANY FIXTURE SEE 202 & | | | 205 RESTROOM STALL DOOR SWINGS INTO THE REQUIRED CLEAR | | | FLOOR SPACE FOR THE LAVATORY. | | | | | | 19)4TH REVIEW 2007 EXISTING BUILDING CODE LEVEL II | | | 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | LS-01 THE VIP PLATFORM #108 & DANCE FLOOR # 107 WILL | | | NEED TO COMPLY WITH VERTICAL ACCESSIBILITY REQUIREMENTS | | | 11-4.1.3(5). | | | | | | 20) COMPLIED. | | | | | | 21)4TH REVIEW, THIS COMMENT MAY OR MAY NOT BE RELEVENT. | | | COMMENTS RESPONCE SHEET INDICATES THE USE OF A | | | SCHINDLERE 3300 MRL ELEVATOR, TO DATE NO PRODUCT SPECS | | | HAVE BEEN SUBMITTED FOR REVIEW. | | | SHEET A4-04 & S-7 DETAIL #2 THE ELEVATOR SHAFT DETAIL | | | IS MISSING THE SUMP PUMP DETAIL 09/A6.121 DETAIL NOT | | | PROVIDED. | | | | | | 22) NOT REQUIRED. | | | ------------------------------------------------------- | | | ---------- | | | | | | 23) 4TH REQUEST. THERE IS A NEW 8X11 INTRODUCTORY | | | OVERVIEW STATEMENT SHEET, INCLUDED IN THE PERMIT | | | PACKAGE, AUTHOR UNKNOWN BUT THE COMMENT INDICATING THAT | | | ALL INTERIOR FINISHES AND FINISH MATERIALS WILL BE | | | SELECTED BY OWNER AND UNDER A SEPERATE CONTRACT SAID | | | MATERIALS INCLUDE ALL FLOOR FINISHES, CEILING MATERIALS | | | & FINISHES ALL WINDOW AND DOOR FINISHES, AND WALL | | | SURFACE FINISHES. | | | | | | WITH THE ABOVE STATEMENT THE PERMIT CAN BE ISSUED AS A | | | PROVISO, BUT A SECONDARY PERMIT WILL NEED TO BE APPLIED | | | FOR BEFORE A C.O. WILL BE ISSUED. | | | THE ARCHITECT OF RECORD SHOULD HAVE A STATEMENT ON THE | | | PLANS INDICATING THAT FINISHES TO BE UNDER A SEPERATE | | | PERMIT. 106.3.5.1.1. COMMERCIAL PLAN REVIEW CRITERIA | | | WOULD REQUIRE THIS INFORMATION BEFORE A PERMIT COULD BE | | | ISSUED, THAT WOULD BE THE REASON IT WOULD BE EXEMPTED | | | FROM THIS PERMIT. | | | | | | 24) THE NEW A SHEETS ARE SIGNED AND SEALED BUT NOT | | | DATED. | | | 61G1-16.004 FL. ADMIN. CODE. PLANS PREPARED BY A | | | REGISTERED ARCHITECT SHALL INCLUDE A TITLE BLOCK WHICH | | | MUST: | | | X= MISSING INFORMATION | | | X - STATE THE FIRM NAME, ADDRESS AND TELEPHONE NUMBER | | | X - STATE THE FIRM LICENSE NUMBER | | | - STATE PROJECT NAME OR IDENTIFICATION | | | - STATE DATE PREPARED | | | X - INCLUDE AN ORIGINAL SIGNATURE AND DATED SEALED | | | INCLUDE THE PRINTED NAME OF THE ARCHITECT SEALING THE | | | PLANS | | | | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER C.B.O. | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561)805-6715 | | | FAX:(561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2012-04-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-04-13 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-04-13 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2012-04-13 10:02:36 | BUILDING PLAN REVIEW | | | PERMIT: 11050596 | | | ADD: 114 S OLIVE AVE | | | CONT: LAKESIDE CONTRACTING CORP | | | TEL: (954)553-8398 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | 2007/09 FLORIDA EXISTING BUILDING CODE W/ SUPPLEMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | APRIL 13,/ 2012 | | | ACTION: DENIED | | | | | | NOTE: THERE ARE NO STRUCTURAL SHEETS IN EITHER SET OF | | | PLANS!!!!! NO S SHEETS!!!! | | | | | | 1) COMPLIED. | | | | | | 2) 3RD REQUEST, NOT FOUND ON EITHER THECOVER SHEET NOR | | | LS-01. WHAT WAS THE LAST KNOWN USE FOR THIS BUILDING, | | | IS THIS A CHANGE OF OCCUPANCY? THE PLANS DO NOT | | | REFERENCE THE FLORIDA EXISTING BUILDING CODE AND TO | | | WHICH TYPE OF COMPLIANCE METHOD THE PLANS WERE DESIGNED | | | TOO? FL EXST BLDG CODE 101.5 (.1-.3). | | | | | | 3A) THIRD REQUEST, NO STRUCTURAL SHEETS WERE SUBMITTED | | | FOR THIS REVIEW. PLEASE REFER TO THE 2007 FBC-B FOR | | | BUILDING TYPE, NOTE THE 2007FBC-B 603.1.3 REQUIRES ALL | | | ROOF CONSTRUCTION GIRDERS, JOIST, TRUSSES AND DECKING | | | ARE TO BE FIRE RETARDANT TREATED WOOD. SHEET S-5 | | | INDICATES THE EXISTING 2X6 ROOF FRAMING, IS THE | | | EXISTING STRUCTURE TRULY A BUILDING TYPE II-B? PLEASE | | | NOTE THE NEW FRAMING MEMBERS LOCATED ON SHEET S-5 DO | | | NOT INDICATE THE USE OF FIRE RETARDANT TREATED WOOD. | | | SHEET INDICATES THE USE OF EXISTING 2X6 ROOF JOISST AND | | | DECKING TO REMAIN. HOW WILL THIS ISSUE BE | | | RESOLVED??????? THIS IS A TYPE II-B CONSTRUCTION. | | | | | | 3B) COMPLIED. | | | | | | 4-7) COMPLIED. | | | | | | 8) SEMI-COMPLIED, PLEASE INDICATE WHERE THE ELEVATOR | | | HYDROLIC PUMP (MACHINE ROOM) WILL BE LOCATED. . PLEASE | | | PROVIDE INFORMATION AS TO SHEET A2-01 & LS-01 WHAT IS | | | THE ROOM # 119 USED FOR IS THIS THE ELEVATOR MACHINE | | | ROOM? IF SO IT NEEDS TO BE RATED AS DOES THE DOOR. | | | | | | 9) 3RD REQUEST. SHEET A2-01 INDICATES NEW RAISED | | | PLATFORM FLOORING PLEASE PROVIDE SQUARE FOOTAGE OF | | | RAISED PLATFORM FLOORING, PLEASE REVIEW SECTION 2007/09 | | | FBC-B 410.4 FIRE RETARDANT TREATED WOOD REQUIREMENT. | | | SECTION 410.4 ONLY ALLOWS 1/3RD OFTHE FLOOR AREA WITHIN | | | A ROOM TO BE ELEVATED. SHEET LS-01 THE ROOM SIZE | | | TABULATION IS NOT CLOSE IN AREAS MISSING ONE MENS | | | RESTROOM AND IT APPEARS THAT FOR ONE OF THE LADIES | | | RESTROOM THE UNISEX RESTROOM WAS PUT IN TWICE AS A | | | LADIES RESTROOM. | | | | | | 10) 3RD REQUEST. NO STRUCTURAL PLANS WERE BROUGHT IN AT | | | THIS TIME TO VERIFY.IT APPEARS THERE MAY BE A | | | DISCREPANCY BETWEEN A2-01 & S-2, ON SHEET S-2 IT | | | APPEARS THERE IS A DOORWAY THAT LEADS FROM THE RAISED | | | DECK IN TO THE STAIRWELL WITH NO LANDING OR STAIRS. | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | | | 11) ROOF HATCH PLEASE BE AWARE OF ADDITIONAL | | | INFORMATION REQUIRED, SHEET A2.04 INDICATES THE USE OF | | | A NEW ROOF HATCH ANS DEETAIL TO BE LOCATED ON SHEET | | | DETAIL # 11 A7.02. MISSING SHEET A7.02. PLEASE SEE | | | FBC-B 1013.5. & 2007/09 MECH CODE 304.10 FOR GUARD | | | REQUIREMENTS WHEN UNITS ARE WITHIN 10'-0" OF THE ROOF | | | EDGE. | | | | | | 11A) GUARDS SHALL BE PROVIDED WHERE APPLIANCES, | | | EQUIPMENT, FANS, ROOF HATCH OPENINGS OR OTHER | | | COMPONENTS THAT REQUIRE SERVICE ARE LOCATED WITHIN 10 | | | FEET (3048 MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING | | | SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN | | | 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE | | | BELOW. THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT | | | THE PASSAGE OF A 21-INCH-DIAMETER (533 MM) SPHERE. THE | | | GUARD SHALL EXTEND NOT LESS THAN 30 INCHES (762 MM) | | | BEYOND EACH END OF SUCH APPLIANCE, EQUIPMENT, FAN OR | | | COMPONENT. | | | | | | 11B) 1013.6 ROOF ACCESS. GUARDS SHALL BE PROVIDED WHERE | | | THE ROOF HATCH OPENING IS LOCATED WITHIN 10 FEET (3048 | | | MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE | | | AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 | | | INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. | | | THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE | | | PASSAGE OF A 21-INCH-DIAMETER (533 MM) SPHERE. | | | | | | | | | 12) COMPLIED. | | | | | | 13) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES, 3 IF THRESHOLD OR RESIDENT INSPECTOR | | | OF PRODUCT TESTING REPORTS, MISSING REPORTS ARE AS | | | FOLLOWS: | | | 13A) WINDOWS | | | 13B) EXTERIOR DOORS | | | 13C) ROOF HATCH | | | 13D) A/C PRE-MANUFACTURED STANDS | | | | | | 14) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 15) SHEET A5-01 STAIR # 1 INDICATES DETAIL 01 ON A-5.03 | | | INDICATES THE USE OF 2X WOOD STRINGERS. 2007/09 FBC-B | | | 1009.5 STAIRWAY CONSTRUCTION. ALL STAIRWAYS SHALL BE | | | BUILT OF MATERIALS CONSISTENT WITH THE TYPES PERMITTED | | | FOR THE TYPE OF CONSTRUCTION OF THE BUILDING, | | | | | | 15B) SHEET A5-03 DETAIL 01 DOES NOT PROVIDE THE RISER | | | DIMENSION FOR STAIRS. 2007/09 FBC-B 1009.3. | | | | | | 16) SHEET A-2.01 THE PLANS DO NOT PROVIDE ELEVATION | | | CHANGE FROM THE CONCRETE DECK TO FINISHED MAIN SEATING | | | AREA NOT THE VIP PLATFORM. FBC-B 1003.5.2. | | | | | | 17) SHEET A-5.02 STAIRWELL # 2. NO STRUCTURAL PLANS | | | WERE SUBMITTED THE TYPE OF MATEIAL FOR STAIR | | | CONSTRUCTION IS NOT PROVIDED 2007/09 FBC-B 1009.5 NOR | | | IS THE RISE NOR RUN OF THE STAIRSFBC-B 1009.3. | | | | | | 16) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | NEW COMMENTS | | | | | | 17) A4-03 & A4-04 : | | | | | | 17A) SEE DETAIL # 4 ON A-34 MISSING SHEET | | | | | | 17B) THE OLD PLANS INDICATE A ROOF / CEILING ASSEMBLY | | | WITH A WIDE BLACK LINE. THE NEW PLANS INDICATE A | | | SEPERATE WOOD ROOF JOIST SYSTEM AND A SEPERATE WOOD | | | CEIING JOIST SYSTEM HOW ARE YOU GOING TO COMPLY AS A | | | TYPE II-B BUILDING WITH NO COMBUSTIBLE FRAMING MEMBERS? | | | 2007/09 FBC-B 603.1 & TABLE 601. | | | | | | 17C) A4-03 ALSO INDICATES A DETAIL # 11 SHEET A8.04 NOT | | | IN PLANS? | | | | | | 18) SHEET LS-02 MEZZANINE RESTROOMS PLEASE SEE | | | 11-411-4.1.3(11) IF TOILET ROOMS ARE PROVIDED, THEN | | | EACH PUBLIC & COMMON USE TOILET ROOM SHALL COMPLY WITH | | | 11-4.22. | | | PLEASE REVIEW 11-4.22(1) DOORS SHALL NOT SWING INTO THE | | | CLEAR FLOOR SPACE REQUIRED FOR ANY FIXTURE. | | | | | | 19) 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | LS-01 THE VIP PLATFORM #108 & DANCE FLOOR # 107 WILL | | | NEED TO COMPLY WITH VERTICAL ACCESSIBILITY REQUIREMENTS | | | 11-4.1.3(5). | | | | | | 20) SHEET A4-05 MISSING DETAAIL 02/ A8.05. | | | | | | 21) SHEET A4-04 & S-7 DETAIL #2 THE ELEVATOR SHAFT | | | DETAIL IS MISSING THE SUMP PUMP DETAIL 09/A6.121 DETAIL | | | NOT PROVIDED. | | | | | | 22) TYPE II BUILDINGS REQUIRE A SPECIAL ONSITE | | | INSPECTOR, BUILDINGS WITH UNUSUAL DESIGN OR METHODS OF | | | CONSTRUCTION. | | | NEW COMMENT | | | ------------------------------------------------------- | | | ---------- | | | | | | 23) THERE IS A NEW 8X11 INTRODUCTORY OVERVIEW STATEMENT | | | SHEET, INCLUDED IN THE PERMIT PACKAGE, AUTHOR UNKNOWN | | | BUT THE COMMENT INDICATING THAT ALL INTERIOR FINISHES | | | AND FINISH MATERIALS WILL BE SELECTED BY OWNER AND | | | UNDER A SEPERATE CONTRACT SAID MATERIALS INCLUDE ALL | | | FLOOR FINISHES, CEILING MATERIALS & FINISHES ALL WINDOW | | | AND DOOR FINISHES, AND WALL SURFACE FINISHES. | | | | | | WITH THE ABOVE STATEMENT THE PERMIT CAN BE ISSUED AS A | | | PROVISO, BUT A SECONDARY PERMIT WILL NEED TO BE APPLIED | | | FOR BEFORE A C.O. WILL BE ISSUED. | | | THE ARCHITECT OF RECORD SHOULD HAVE A STATEMENT ON THE | | | PLANS INDICATING THAT FINISHES TO BE UNDER A SEPERATE | | | PERMIT. 106.3.5.1.1. COMMERCIAL PLAN REVIEW CRITERIA | | | WOULD REQUIRE THIS INFORMATION BEFORE A PERMIT COULD BE | | | ISSUED, THAT WOULD BE THE REASON IT WOULD BE EXEMPTED | | | FROM THIS PERMIT. | | | | | | 24) THE NEW A SHEETS ARE SIGNED AND SEALED BUT NOT | | | DATED. | | | 61G1-16.004 FL. ADMIN. CODE. PLANS PREPARED BY A | | | REGISTERED ARCHITECT SHALL INCLUDE A TITLE BLOCK WHICH | | | MUST: | | | X= MISSING INFORMATION | | | X - STATE THE FIRM NAME, ADDRESS AND TELEPHONE NUMBER | | | X - STATE THE FIRM LICENSE NUMBER | | | - STATE PROJECT NAME OR IDENTIFICATION | | | - STATE DATE PREPARED | | | X - INCLUDE AN ORIGINAL SIGNATURE AND DATED SEALED | | | INCLUDE THE PRINTED NAME OF THE ARCHITECT SEALING THE | | | PLANS | | | | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER C.B.O. | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561)805-6715 | | | FAX:(561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2012-02-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-02-28 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-02-28 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2012-02-28 14:22:16 | BUILDING PLAN REVIEW | | | PERMIT: 11050596 | | | ADD: 114 S OLIVE AVE | | | CONT: LAKESIDE CONTRACTING CORP | | | TEL: (954)553-8398 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | 2007/09 FLORIDA EXISTING BUILDING CODE W/ SUPPLEMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | FEB. 28/ 2012 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) WHAT WAS THE LAST KNOWN USE FOR THIS BUILDING, IS | | | THIS A CHANGE OF OCCUPANCY? THE PLANS DO NOT REFERENCE | | | THE FLORIDA EXISTING BUILDING CODE AND TO WHICH TYPE OF | | | COMPLIANCE METHOD THE PLANS WERE DESIGNED TOO? FL EXST | | | BLDG CODE 101.5 (.1-.3). | | | | | | 3A) SEMI-COMPLIED. PLEASE REFER TO THE 2007 FBC-B FOR | | | BUILDING TYPE, NOTE THE 2007FBC-B 603.1.3 REQUIRES ALL | | | ROOF CONSTRUCTION GIRDERS, JOIST, TRUSSES AND DECKING | | | ARE TO BE FIRE RETARDANT TREATED WOOD. SHEET S-5 | | | INDICATES THE EXISTING 2X6 ROOF FRAMING, IS THE | | | EXISTING STRUCTURE TRULY A BUILDING TYPE II-B? PLEASE | | | NOTE THE NEW FRAMING MEMBERS LOCATED ON SHEET S-5 DO | | | NOT INDICATE THE USE OF FIRE RETARDANT TREATED WOOD. | | | | | | 3B) COMPLIED. | | | | | | 4-7) COMPLIED. | | | | | | 8) 2ND REQUEST. PLEASE PROVIDE INFORMATION AS TO SHEET | | | A2-01 & LS-01 WHAT IS THE ROOM # 119 USED FOR IS THIS | | | THE ELEVATOR MACHINE ROOM? IF SO IT NEEDS TO BE RATED | | | AS DOES THE DOOR. | | | | | | 9) 2ND REQUEST. SHEET A2-01 INDICATES NEW RAISED | | | PLATFORM FLOORING PLEASE PROVIDE SQUARE FOOTAGE OF | | | RAISED PLATFORM FLOORING, PLEASE REVIEW SECTION 2007/09 | | | FBC-B 410.4 FIRE RETARDANT TREATED WOOD REQUIREMENT. | | | | | | 10) 2ND REQUEST. IT APPEARS THERE MAY BE A DISCREPANCY | | | BETWEEN A2-01 & S-2, ON SHEET S-2 IT APPEARS THERE IS A | | | DOORWAY THAT LEADS FROM THE RAISED DECK IN TO THE | | | STAIRWELL WITH NO LANDING OR STAIRS. 106.1.2 ADDITIONAL | | | INFORMATION REQUIRED. | | | | | | 11) ROOF HATCH PLEASE BE AWARE OF ADDITIONAL | | | INFORMATION REQUIRED, SHEET A8.01 INDICATES THE USE OF | | | A NEW ROOF HATCH PLEASE SEE FBC-B 1013.5. & 2007/09 | | | MECH CODE 304.10 FOR GUARD REQUIREMENTS WHEN UNITS ARE | | | WITHIN 10'-0" OF THE ROOF EDGE. | | | | | | 11A) GUARDS SHALL BE PROVIDED WHERE APPLIANCES, | | | EQUIPMENT, FANS, ROOF HATCH OPENINGS OR OTHER | | | COMPONENTS THAT REQUIRE SERVICE ARE LOCATED WITHIN 10 | | | FEET (3048 MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING | | | SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN | | | 30 INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE | | | BELOW. THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT | | | THE PASSAGE OF A 21-INCH-DIAMETER (533 MM) SPHERE. THE | | | GUARD SHALL EXTEND NOT LESS THAN 30 INCHES (762 MM) | | | BEYOND EACH END OF SUCH APPLIANCE, EQUIPMENT, FAN OR | | | COMPONENT. | | | | | | 11B) 1013.6 ROOF ACCESS. GUARDS SHALL BE PROVIDED WHERE | | | THE ROOF HATCH OPENING IS LOCATED WITHIN 10 FEET (3048 | | | MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE | | | AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 | | | INCHES (762 MM) ABOVE THE FLOOR, ROOF OR GRADE BELOW. | | | THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE | | | PASSAGE OF A 21-INCH-DIAMETER (533 MM) SPHERE. | | | | | | | | | 12) COMPLIED. | | | 13) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES, 3 IF THRESHOLD OR RESIDENT INSPECTOR | | | OF PRODUCT TESTING REPORTS, MISSING REPORTS ARE AS | | | FOLLOWS: | | | 13A) WINDOWS | | | 13B) ROOF HATCH | | | 13C) A/C PRE-MANUFACTURED STANDS | | | | | | 14) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 15) MISSING DETAILS SHEET A5-01 STAIR # 1 INDICATES | | | DETAIL 12 ON A-13 NO SHEET IS INDICATED ON THE | | | ARCHITECTURAL INDEX. | | | | | | 15B) MISSING DETAIL SHEET A---02 STAIR # 2 IS MISSING | | | DETAIL SHEET A-13 & A-14. | | | | | | 16) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | NEW COMMENTS | | | | | | 17) A4-03 & A4-04 : | | | | | | 17A) SEE DETAIL # 4 ON A-34 MISSING SHEET | | | | | | 17B) THE OLD PLANS INDICATE A ROOF / CEILING ASSEMBLY | | | WITH A WIDE BLACK LINE. THE NEW PLANS INDICATE A | | | SEPERATE WOOD ROOF JOIST SYSTEM AND A SEPERATE WOOD | | | CEIING JOIST SYSTEM HOW ARE YOU GOING TO COMPLY AS A | | | TYPE II-B BUILDING WITH NO COMBUSTIBLE FRAMING MEMBERS? | | | 2007/09 FBC-B 603.1 & TABLE 601. | | | | | | 17C) A4-03 ALSO INDICATES A DETAIL # 11 SHEET A8.04 NOT | | | IN PLANS? | | | | | | 18) SHEET LS-02 MEZZANINE RESTROOMS PLEASE SEE | | | 11-411-4.1.3(11) IF TOILET ROOMS ARE PROVIDED, THEN | | | EACH PUBLIC & COMMON USE TOILET ROOM SHALL COMPLY WITH | | | 11-4.22. | | | PLEASE REVIEW 11-4.22(1) DOORS SHALL NOT SWING INTO THE | | | CLEAR FLOOR SPACE REQUIRED FOR ANY FIXTURE. | | | | | | 19) 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | LS-01 THE VIP PLATFORM #108 & DANCE FLOOR # 107 WILL | | | NEED TO COMPLY WITH VERTICAL ACCESSIBILITY REQUIREMENTS | | | 11-4.1.3(5). | | | | | | 20) SHEET A4-05 MISSING DETAAIL 02/ A8.05. | | | | | | 21) SHEET A4-04 & S-7 DETAIL #2 THE ELEVATOR SHAFT | | | DETAIL IS MISSING THE SUMP PUMP DETAIL 09/A6.121 DETAIL | | | NOT PROVIDED. | | | | | | 22) TYPE II BUILDINGS REQUIRE A SPECIAL ONSITE | | | INSPECTOR, BUILDINGS WITH UNUSUAL DESIGN OR METHODS OF | | | CONSTRUCTION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER C.B.O. | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561)805-6715 | | | FAX:(561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-05-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-05-31 |
Time |
15:03 |
Rev Time |
7.00 |
| Received By |
jwitmer |
Date |
2011-05-26 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2011-05-31 15:04:50 | | | | BUILDING PLAN REVIEW | | | PERMIT: 11050596 | | | ADD: 114 S OLIVE AVE | | | CONT: LAKESIDE CONTRACTING CORP | | | TEL: (954)553-8398 | | | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | 2007/09 FLORIDA EXISTING BUILDING CODE W/ SUPPLEMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PLEASE PROVIDE PLANS OF THE EXISTING SPACE | | | INDICATING WHERE THE STAIRWELLS AND EXISTING EXIT | | | LOCATIONS. IT APPEARS THE MEZZANINE IS A NEW LEVEL? | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. 2007/09 FL | | | EXST BLDG CODE 701.3 NEW WORK. | | | | | | 2) WHAT WAS THE LAST KNOWN USE FOR THIS BUILDING, IS | | | THIS A CHANGE OF OCCUPANCY? THE PLANS DO NOT REFERENCE | | | THE FLORIDA EXISTING BUILDING CODE AND TO WHICH TYPE OF | | | COMPLIANCE METHOD THE PLANS WERE DESIGNED TOO? FL EXST | | | BLDG CODE 101.5 (.1-.3). | | | | | | 3A) SHEET A-1.0 THE BUILDING & CODE INFORMATION | | | INDICATES THIS BUILDING TYPE UNDER THE 1997 UBC AS A | | | TYPE II-B NON-COMBUSTIBLE/ NONRATED. PLEASE REFER TO | | | THE 2007 FBC-B FOR BUILDING TYPE, NOTE THE 2007FBC-B | | | 603.1.3 REQUIRES ALL ROOF CONSTRUCTION GIRDERS, JOIST, | | | TRUSSES AND DECKING ARE TO BE FIRE RETARDANT TREATED | | | WOOD. SHEET S-5 INDICATES THE EXISTING 2X6 ROOF | | | FRAMING, IS THE EXISTING STRUCTURE TRULY A BUILDING | | | TYPE II-B? PLEASE NOTE THE NEW FRAMING MEMBERS LOCATED | | | ON SHEET S-5 DO NOT INDICATE THE USE OF FIRE RETARDANT | | | TREATED WOOD. | | | | | | 3B) THE BUILDING & CODE INFORMATION FOUND ON SHEET A-1 | | | DOES NOT INDICATE IF THIS IS A FIRE SPRINKLERED | | | BUILDING? 2007/09 FBC-B 106.3.5.1.1. MINIMUM PLAN | | | REVIEW CRITERIA. | | | | | | 4A) PLEASE PROVIDE A LIFE SAFETY PLAN W/ FURNISHINGS | | | OCCUPANT LOADS & EGRESS CAPACITIES. 2007/09 FBC-B | | | 106.3.5.1.1(6). | | | | | | 4B) PLEASE PROVIDE COMMON PATH OF TRAVEL FOR THE FIRST | | | FLOOR SEE LIMITATIONS 1014.3 FOR THE FIRST FLOOR AS | | | WELL AS THE MEZZANINE LEVEL AND THE SECOND FLOOR. | | | REVIEW SECTION 505.3 FOR THE MEZZANINE MAXIMUM TRAVEL | | | DISTANCE INCLUDES THE DISTANCE TRAVELED ON THE STAIRWAY | | | MEASURED IN THE PLANE OF THE TREAD NOSING. | | | | | | 4C) PLEASE PROVIDE ADDITIONAL INFORMATION AS TO THE | | | OCCUPANCY SEPARATION IN CONJUNCTION TO THE OPEN AIR | | | STAIR BETWEEN THE MEZZANINE LEVEL AND THE 2ND FLOOR | | | LEVEL? | | | 2007 FBC-B TABLE 508.3.3. | | | | | | 4D) THE SECOND FLOOR FRONT STAIRWAY IS IN THE SAME | | | STAIRWELL AS THE ELEVATOR. 2007 FBC-B 3002.7 COMMON | | | ENCLOSURE WITH STAIRWAY. ELEVATORS SHALL NOT BE IN A | | | COMMON SHAFT ENCLOSURE WITH A STAIRWAY. THE 1ST FLOOR | | | AND MEZZANINE LEVEL WOULD BE OK SINCE THE MEZZANINE | | | LEVEL IS NOT CONSIDERED A STORY. HOW WILL SMOKE | | | ACCUMULATION IN THE STAIRWELL BE HANDLED SINCE THE | | | FLOOR BELOW (MEZZANINE LEVEL) IS OPEN. | | | | | | 4E) THE SECOND FLOOR FRONT STAIRWELL WILL NEED TO | | | INDICATE FIRE RATING ON THE WALLS AND OPENING | | | PENETRATIONS. FBC 1020.1 & TABLE 715.4. SHEET A8.03 | | | INDICATES WALL RATINGS BUT THE FLOOR PLANS DO NOT TIE | | | THEM TO ANY WALLS WITH WALL MARKERS. THE SAME HOLDS | | | TRUE FOR RATING OF FIRE RATED DOORS THE DOOR SCHEDULE | | | DOES NOT PROVIDE ANY DOOR OPENINGS THAT WOULD REQUIRE | | | FIRE RATING, STAIRWELL ENTRY DOORS, THE 2ND FLOOR | | | STAIRWELL, | | | | | | 5) PROVIDE THE OCCUPANT LOADS PER 2007/09 FBC-B | | | 106.3.5.1.1(7) OCCUPANT LOADS FOR EACH OF THE ASSEMBLY | | | AREAS WITH BREAKDOWN IF 5 NET, 7 NET OR 15 NET, PER | | | FLOOR AND FOR THE BUSINESS OCCUPANCY. FBC-B TABLE | | | 1004.1.1. | | | | | | 6) SHEET A-1 ALSO FAILS TO PROVIDE INFORMATION ON | | | OCCUPANCY SEPARATION BETWEEN THE A2 OCCUPANCY AND THE | | | BUSINESS OCCUPANCY LOCATED ON THE 2ND FLOOR, PLEASE | | | PROVIDE DESIGN CRITERIA 2007/09 FBC-B 508.3.1.3. | | | | | | 7) DEPENDING ON THE OCCUPANT LOAD OF THE A2 OCCUPANCY | | | THIS BUILDING MAY END UP BEING CLASSIFIED AS A | | | THRESHOLD BUILDINGREQIRING THE FOLLOWING: | | | | | | THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) " | | | THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH | | | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN | | | THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN | | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | | | | 7A)109.3.6.1 THE ENFORCING AGENCY SHALL REQUIRE A | | | SPECIAL INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON | | | A THRESHOLD BUILDING PURSUANT TO A STRUCTURAL | | | INSPECTION PLAN PREPARED BY THE ENGINEER OF RECORD. THE | | | STRUCTURAL INSPECTION PLAN MUST BE SUBMITTED TO THE | | | ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A BUILDING | | | PERMIT FOR THE CONSTRUCTION OF A THRESHOLD BUILDING. | | | THE PURPOSE OF THE STRUCTURAL INSPECTION PLAN IS TO | | | PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO | | | THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR | | | COMPLIANCE WITH THE PERMITTED DOCUMENTS. | | | | | | 7B) THRESHOLD INSPECTOR: | | | WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES | | | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL | | | INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA | | | STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS | | | CODE. | | | CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR | | | PROGRAM AT (561)805-6666 FOR FURTHER INFORMATION | | | BEFORE THE PERMIT MAY BE ISSUED. | | | | | | 7C) THRESHOLD BLDG, REQUIRED STATEMENT: | | | W.P.B. AMENDMENT 109.3.6.4.4 ALL PLANS FOR THE BUILDING | | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | | LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 7D) A HOLD WILL BE PUT ON THIS PROJECT UNTIL THESE | | | ITEMS ARE COMPLETED AS REQUESTED BY THE CHIEF BUILDING | | | INSPECTOR KEN CONRAD: | | | | | | PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR | | | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS. | | | | | | 1) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | | FOR THIS TYPE OF CONCRETE RESTORATION. | | | THIS MAY BE SUBMITTED TO KEN CONRAD BY E-MAIL. KEN | | | CONRAD: [email protected] | | | | | | 2) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | CONTACT KEN CONRAD | | | TEL: 561-805-6666 | | | E-MAIL: [email protected] | | | | | | 8) PLEASE PROVIDE INFORMATION AS TO SHEET A-6 WHAT IS | | | THE ROOM # 119 USED FOR IS THIS THE ELEVATOR MACHINE | | | ROOM? IF SO IT NEEDS TO BE RATED AS DOES THE DOOR. | | | | | | 9) SHEET A-6 & S-2 INDICATES NEW RAISED PLATFORM | | | FLOORING PLEASE PROVIDE SQUARE FOOTAGE OF RAISED | | | PLATFORM FLOORING, PLEASE REVIEW SECTION 2007/09 FBC-B | | | 410.4 FIRE RETARDANT TREATED WOOD REQUIREMENT. | | | | | | 10) IT APPEARS THERE MAY BE A DISCREPANCY BETWEEN A-6 & | | | S-2, ON SHEET S-2 IT APPEARS THERE IS A DOORWAY THAT | | | LEADS FROM THE RAISED DECK IN TO THE STAIRWELL WITH NO | | | LANDING OR STAIRS. 106.1.2 ADDITIONAL INFORMATION | | | REQUIRED. | | | | | | 11) ADDITIONAL INFORMATION REQUIRED, SHEET A8.01 | | | INDICATES THE USE OF A NEW ROOF HATCH WHICH IS NOT | | | INDICATED ON EITHER THE ARCHITECTURAL NOR STRUCTURAL | | | SHEETS. SHEET A8 IN STORAGE ROOM 304-A HAS WHAT APPEARS | | | TO BE A LADDER AND POSSIBLE LOCATION FOR THE ROOF HATCH | | | THE SECTION 11/ A-16 DOES NOT MATCH UP WITH ANY PLANS | | | WITHIN THIS SET, ADDITIONAL INFORMATION IS REQUIRED. | | | PLEASE REVIEW 2007/09 FBC-B 1509.6 FOR PERMANENT LADDER | | | REQUIREMENTS. PLEASE REVIEW 2007/09 MECH CODE 304.10 | | | FOR GUARD REQUIREMENTS WHEN UNITS ARE WITHIN 10?-0? OF | | | THE ROOF EDGE. | | | | | | 12) SHEET A-21 EAST ELEVATION INDICATES THE USE OF AN | | | EXISTING FIRE ESCAPE EXIT DOORS AND WINDOW # 12 BEING | | | REPLACED. PLEASE REVIEW 2007/09 EXST BLDG CODE 303.5 | | | OPENING PROTECTION. DOORS AND WINDOWS ALONG THE FIRE | | | ESCAPE SHALL BE PROTECTED WITH ? HR OPENING | | | PROTECTIVES. | | | | | | 13) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES, 3 IF THRESHOLD OR RESIDENT INSPECTOR | | | OF PRODUCT TESTING REPORTS, MISSING REPORTS ARE AS | | | FOLLOWS: | | | 13A) WINDOWS | | | 13B) ROOF HATCH | | | 13C) A/C PRE-MANUFACTURED STANDS | | | | | | 14) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 15A) SHEET A-53 STAIR DESIGN NEEDS TO BE UPDATED FROM | | | THE 1997 UBC. | | | | | | 15B) SHEET A-53 STAIR NOTE # 3 PLEASE UPDATE NOTE TO | | | THE 2007/09 FBC-B 1607.1.2 | | | INTERMEDIATE RAILS SHALL BE DESIGNED TO WITHSTAND | | | HORIZONTALLY | | | | | | 16) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER C.B.O. | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561)805-6715 | | | FAX:(561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2012-04-23 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-04-23 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-04-23 |
Time |
12:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2012-03-26 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-03-26 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-03-26 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2012-03-26 16:34:13 | RESUB DID NOT INCLUDE A RESPONSE TO ELECTRICAL COMMENTS | | | OF 6/1/2011 | | | | | | ROBERT LECKY | | | ELECTRIC PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2012-02-29 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2012-02-29 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2012-02-29 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2012-02-29 17:13:29 | RESUB DID NOT INCLUDE A RESPONSE TO ELECTRICAL COMMENTS | | | OF 6/1/2011 | | | | | | ROBERT LECKY | | | ELECTRIC PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-06-01 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-06-01 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-06-01 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2011-06-01 15:39:28 | PROVIDE SPECIFICATIONS FOR THE NEW ELECTRICAL SERVICE | | | EQUIPMENT SHOWING THE EQUIPMENT SELECTED IS CAPABLE OF | | | INTERRUPTING THE AVAILABLE FAULT CURRENT. NEC 110.9, | | | 110.10 | | | PROVIDE A DETAIL SHOWING THAT THE REQUIRED WORKING | | | CLEARANCES AND DEDICATED WORKING SPACE HAS BEEN | | | PROVIDED FOR THE ELECTRICAL EQUIPMENT. NEC 110.26, | | | 240.24, 408.17 | | | PROVIDE SPECIFICATIONS AND LISTING FROM AN APPROVED | | | TESTING AGENCY FOR THE CUSTOM LIGHTING FIXTURES. NEC | | | 110.3 | | | VERIFY ALL CUSTOM SOUND AND LIGHT SYSTEMS ARE LISTED BY | | | AN APPROVED TESTING AGENCY. NEC 110.3 | | | PROVIDE A STRUCTURAL SUPPORT DETAIL FOR LIGHT FIXTURES | | | AND LIGHTING ARRAYS RATED AT MORE THAN 50 POUNDS. NEC | | | 410.36, 314.27 | | | A SEPARATE PLAN AND ELECTRICAL PERMIT IS REQUIRED FOR | | | THE FIRE ALARM SYSTEM. | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2012-07-12 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-07-12 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-07-12 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2012-07-12 10:32:28 | 114 SOUTH OLIVE AVENUE | | | PERMIT #11050596 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NOTE: THE RESPONSE LETTER FROM THE ARCHITECT (WILLIAM | | | FRASER) DATED FEBRUARY 16, 2012 ADDRESSES THE FIRE | | | REVIEW COMMENTS; HOWEVER, MUCH OF THE RESPONSE | | | INFORMATION IS NOT SHOWN ON THE PLANS. | | | | | | | | | PROVIDE TACTILE SIGNAGE AT EXIT DOORS. | | | | | | EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS | | | SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A | | | CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. | | | SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | SHEET A0.01: WHEN THE OCCUPANT LOAD EXCEEDS 300 PERSONS | | | AND THE BUILDING IS FULLY SPRINKLERED, THE INTERIOR | | | WALL AND CEILING FINISHES SHALL BE AS FOLLOWS: | | | -ENCLOSED STAIRWAYS SHALL BE CLASS A OR B | | | | | | SHEET FP-01: STAIR LOBBY STEPS SHALL HAVE A TREAD DEPTH | | | OF AT LEAST 13-INCHES. PROVIDE A CONTRASTING STRIPE ON | | | EACH STEPPING SURFACE OF THE LEADING EDGE OR TREAD | | | NOSING TO MAKE THE PRESENCE OF AN ELEVATION CHANGE | | | READILY APPARENT TO OCCUPANTS. | | | | | | SHEET A2-03: STAIR DOOR #301 TO CATWALK SHALL BE LOCKED | | | AT ALL TIMES. PERMANENT SIGN READING "AUTHORIZED | | | PERSONNEL ONLY" SHALL BE AFFIXED TO THE DOOR. | | | | | | MEP SHEETS: PROJECT ADDRESS IS INCORRECTLY INDICATED AS | | | "114 STONE STREET." | | | | | | SHEET F2-1: CIVIL PLANS NOT SUBMITTED SHOWING FIRE LINE | | | CONNECTION TO CITY SUPPLY, BACKFLOW PREVENTER, FIRE | | | HYDRANT LOCATION IN RELATION TO FDC, ETC. | | | | | | SHEET F2-1: FIRE DEPARTMENT CONNECTION SHALL BE LOCATED | | | WITHIN 150 FEET OF A FIRE HYDRANT. LOCATE FDC ON OLIVE | | | AVENUE. | | | | | | SHEET F3-1: PER FLORIDA ADMINISTRATIVE CODE SECTION | | | 61G15-32.004, PLANS SHALL INDICATE THE HAZARD | | | CLASSIFICATIONS, DESIGN DENSITIES, AND HYDRANT FLOW | | | TEST DATA. | | | | | | SHEET A8-01: STAIR DOORS DO NOT HAVE A FIRE-RATING. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2012-04-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-04-25 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-04-24 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2012-04-24 15:41:19 | 114 SOUTH OLIVE AVENUE | | | PERMIT #11050596 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NOTE: THE RESPONSE LETTER FROM THE ARCHITECT (WILLIAM | | | FRASER) DATED FEBRUARY 16, 2012 ADDRESSES THE FIRE | | | REVIEW COMMENTS; HOWEVER, MUCH OF THE RESPONSE | | | INFORMATION IS NOT SHOWN ON THE PLANS. | | | | | | | | | PROVIDE TACTILE SIGNAGE AT EXIT DOORS. | | | | | | EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS | | | SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A | | | CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. | | | SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | SHEET A0.01: WHEN THE OCCUPANT LOAD EXCEEDS 300 PERSONS | | | AND THE BUILDING IS FULLY SPRINKLERED, THE INTERIOR | | | WALL AND CEILING FINISHES SHALL BE AS FOLLOWS: | | | -ENCLOSED STAIRWAYS SHALL BE CLASS A OR B | | | | | | SHEET FP-01: STAIR LOBBY STEPS SHALL HAVE A TREAD DEPTH | | | OF AT LEAST 13-INCHES. PROVIDE A CONTRASTING STRIPE ON | | | EACH STEPPING SURFACE OF THE LEADING EDGE OR TREAD | | | NOSING TO MAKE THE PRESENCE OF AN ELEVATION CHANGE | | | READILY APPARENT TO OCCUPANTS. | | | | | | SHEET A2-03: STAIR DOOR #301 TO CATWALK SHALL BE LOCKED | | | AT ALL TIMES. PERMANENT SIGN READING "AUTHORIZED | | | PERSONNEL ONLY" SHALL BE AFFIXED TO THE DOOR. | | | | | | MEP SHEETS: PROJECT ADDRESS IS INCORRECTLY INDICATED AS | | | "114 STONE STREET." | | | | | | SHEET F2-1: CIVIL PLANS NOT SUBMITTED SHOWING FIRE LINE | | | CONNECTION TO CITY SUPPLY, BACKFLOW PREVENTER, FIRE | | | HYDRANT LOCATION IN RELATION TO FDC, ETC. | | | | | | SHEET F2-1: FIRE DEPARTMENT CONNECTION SHALL BE LOCATED | | | WITHIN 150 FEET OF A FIRE HYDRANT. LOCATE FDC ON OLIVE | | | AVENUE. | | | | | | SHEET F3-1: PER FLORIDA ADMINISTRATIVE CODE SECTION | | | 61G15-32.004, PLANS SHALL INDICATE THE HAZARD | | | CLASSIFICATIONS, DESIGN DENSITIES, AND HYDRANT FLOW | | | TEST DATA. | | | | | | SHEET A8-01: STAIR DOORS DO NOT HAVE A FIRE-RATING. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2012-03-05 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2012-03-05 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2012-03-05 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2012-03-05 11:46:10 | 114 SOUTH OLIVE AVENUE | | | PERMIT #11050596 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | DESIGN SHALL CONFORM TO THE FLORIDA FIRE PREVENTION | | | CODE 2007 EDITION: NFPA 1 AND NFPA 101 - 2006 EDITION | | | WITH FLORIDA AMENDMENTS. | | | | | | ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS | | | OF NFPA 241. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | PROVIDE A CIVIL ENGINEERING PLAN SHOWING UNDERGROUND | | | UTILITIES, CONNECTIONS, FIRE HYDRANTS, PIPE SIZES ETC. | | | | | | PROVIDE TACTILE SIGNAGE AT EXIT DOORS. | | | | | | EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS | | | SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A | | | CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. | | | SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | SHEET A0.01: NFPA 5000 IS NOT ADOPTED BY THE STATE OF | | | FLORIDA. | | | | | | SHEET A0.01: WHEN THE OCCUPANT LOAD EXCEEDS 300 PERSONS | | | AND THE BUILDING IS FULLY SPRINKLERED, THE INTERIOR | | | WALL AND CEILING FINISHES SHALL BE AS FOLLOWS: | | | -ENCLOSED STAIRWAYS SHALL BE CLASS A OR B | | | -CORRIDORS AND LOBBIES SHALL BE CLASS A, B OR C | | | -GENERAL ASSEMBLY AREAS SHALL BE CLASS A, B OR C | | | | | | SHEET LS-01: PROVIDE HANDRAILS FOR STAIR #111. | | | | | | SHEET FP-01: LOBBY STEP AND GRAND STAIR LOBBY STEP | | | SHALL HAVE A TREAD DEPTH OF AT LEAST 13-INCHES. PROVIDE | | | A CONTRASTING STRIPE ON EACH STEPPING SURFACE OF THE | | | LEADING EDGE OR TREAD NOSING TO MAKE THE PRESENCE OF AN | | | ELEVATION CHANGE READILY APPARENT TO OCCUPANTS. | | | | | | SHEET A2-01: NO ROOM NAMES OR DOOR SCHEDULE PROVIDED | | | FOR DOOR #118 AND #119. | | | | | | SHEET A2-03: STAIR DOOR #301 TO CATWALK SHALL BE LOCKED | | | AT ALL TIMES. PERMANENT SIGN READING "AUTHORIZED | | | PERSONNEL ONLY" SHALL BE AFFIXED TO THE DOOR. | | | | | | MEP SHEETS: PROJECT ADDRESS IS INCORRECTLY INDICATED AS | | | "114 STONE STREET." | | | | | | SHEET F2-1: CIVIL PLANS NOT SUBMITTED SHOWING FIRE LINE | | | CONNECTION TO CITY SUPPLY, BACKFLOW PREVENTER, FIRE | | | HYDRANT LOCATION IN RELATION TO FDC, ETC. | | | | | | SHEET F2-1: FIRE DEPARTMENT CONNECTION SHALL BE LOCATED | | | WITHIN 150 FEET OF A FIRE HYDRANT. LOCATE FDC ON OLIVE | | | AVENUE. | | | | | | SHEET F3-1: PER FLORIDA ADMINISTRATIVE CODE SECTION | | | 61G15-32.004, PLANS SHALL INDICATE THE HAZARD | | | CLASSIFICATIONS, DESIGN DENSITIES, AND HYDRANT FLOW | | | TEST DATA. | | | | | | SHEET E2-2: PLANS DO NOT INDICATE THE METHOD (HEAT | | | DETECTOR/FLOW SWITCH WITHOUT TIME DELAY) USED TO SHUNT | | | TRIP POWER TO THE ELEVATOR IN THE EVENT AN AUTOMATIC | | | SPRINKLER ACTIVATES IN THE ELEVATOR MACHINE ROOM. | | | | | | SHEET A8-01: STAIR DOORS DO NOT HAVE A FIRE-RATING. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-06-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-06-03 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-06-03 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2011-06-03 12:55:26 | 114 SOUTH OLIVE AVENUE | | | PERMIT #11050596 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | DESIGN SHALL CONFORM TO THE FLORIDA FIRE PREVENTION | | | CODE 2007 EDITION: NFPA 1 AND NFPA 101 - 2006 EDITION | | | WITH FLORIDA AMENDMENTS. | | | | | | ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS | | | OF NFPA 241. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE APPROVED AND SUBMITTED IN WRITING TO THE OFFICE OF | | | THE FIRE MARSHAL. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | PROVIDE BUILDING ADDRESS VISIBLE FROM THE STREET. | | | NUMBERS SHALL BE AT LEAST SIX-INCHES IN HEIGHT AND | | | SHALL CONTRAST THE BACKGROUND PER NFPA 1 - FLORIDA | | | EDITION. | | | | | | PROVIDE A CIVIL ENGINEERING PLAN SHOWING UNDERGROUND | | | UTILITIES, CONNECTIONS, FIRE HYDRANTS, PIPE SIZES ETC. | | | | | | PROVIDE A LIFE SAFETY PLAN (WITH FURNITURE) SHOWING | | | OCCUPANT LOADS, TRAVEL DISTANCES TO EXITS, EXIT SIGNS, | | | FIRE EXTINGUISHERS, FIRE-RATED WALLS, ETC. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | | | PROVIDE TACTILE SIGNAGE AT EXIT DOORS. | | | | | | REFLECTED CEILING PLANS DO NOT INDICATE CEILING | | | ELEVATIONS. | | | | | | STAIR DOORS DO NOT HAVE A FIRE-RATING ACCORDING THE | | | DOOR SCHEDULE ON SHEET A-71. | | | | | | EVERY FLOOR SERVED BY THE ELEVATOR SHALL HAVE AN | | | ELEVATOR LOBBY WITH A ONE-HOUR FIRE RATING PER SECTION | | | 7.2.13.3 OF NFPA 101 - FLORIDA EDITION. ALSO, ELEVATORS | | | SHALL NOT OPEN TO AN EXIT PER SECTION 9.4.7 OF NFPA 101 | | | - FLORIDA EDITION. | | | | | | SHEET A1-1: PROVIDE ADDITIONAL INFORMATION FOR EXISTING | | | METAL CATWALK AND STAIR THAT IS TO REMAIN. INDICATE | | | STAIR DISCHARGE LOCATION. | | | | | | SHEET A-6: GRAND STAIR #103 IS SERVING AS AN EXIT. ALL | | | INSIDE STAIRS SERVING AS AN EXIT OR EXIT COMPONENT | | | SHALL BE ENCLOSED PER SECTION 7.2.2.5.1.1 OF NFPA 101 - | | | FLORIDA EDITION. | | | | | | SHEET A-6: TICKET RAMP APPEARS TO ONLY HAVE ONE | | | HANDRAIL. | | | | | | SHEET A-7: THE PLAN IS DESIGNATED AS A MEZZANINE BUT | | | DOES NOT MEET THE DEFINITION OF MEZZANINE AS PROVIDED | | | IN THE FLORIDA BUILDING CODE. THIS LEVEL IS FUNCTIONING | | | AS A FLOOR AND NEEDS TO HAVE OPENINGS PROTECTED. | | | | | | SHEET A-8: THE DOOR SWING OF #322 OBSTRUCTS ACCESS TO | | | EXIT STAIR #2. | | | | | | SHEET A-8: SOME ROOMS REQUIRE TRAVEL THROUGH ANOTHER | | | ROOM TO REACH AN EXIT. THESE DOORS CANNOT BE SUBJECT TO | | | LOCKING AND PROHIBIT EGRESS. | | | | | | SHEET A-8: EXTERIOR STAIRS SHALL BE SEPARATED AND HAVE | | | PROTECTED OPENINGS PER SECTION 7.2.2.6 OF NFPA 101 - | | | FLORIDA EDITION. | | | | | | SHEET E2-3: PROVIDE SPEAKER/STROBE NOTIFICATION | | | APPLIANCES FOR VOICE EVACUATION SYSTEM. MOST | | | NOTIFICATION APPLIANCES ARE SHOWN AS HORN/STROBES. | | | | | | SHEET E2-3: PROVIDE NOTIFICATION APPLIANCE IN CORRIDOR | | | #116. | | | | | | SHEET F2-1: CIVIL PLANS NOT SUBMITTED SHOWING FIRE LINE | | | CONNECTION TO CITY SUPPLY, BACKFLOW PREVENTER, FIRE | | | HYDRANT LOCATION IN RELATION TO FDC, ETC. | | | | | | SHEET F3-1: PER FLORIDA ADMINISTRATIVE CODE SECTION | | | 61G15-32.004, PLANS SHALL INDICATE THE HAZARD | | | CLASSIFICATIONS, DESIGN DENSITIES, AND HYDRANT FLOW | | | TEST DATA. | | | | | | NOTE: A DRAWING INDEX WOULD HELP EXPLAIN THE GAP IN | | | DRAWING NUMBER SEQUENCE. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-05-19 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-05-19 |
Time |
14:56 |
Rev Time |
0.25 |
| Received By |
jpapa |
Date |
2011-05-19 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2012-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-24 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-06-18 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2012-06-19 10:14:34 | RESUBMITTAL BUILDING ONLY | | | GAVE RESUB TO JIM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2012-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2012-07-12 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2012-04-12 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2012-04-12 11:03:16 | EXPEDITED | | | C--27 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2012-04-12 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2012-03-26 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-02-22 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2012-02-22 17:26:23 | REVISED DRAWINGS | | 2012-02-22 17:26:07 | EXPEDITED | | | C-27 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2012-01-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2012-01-09 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2012-01-19 13:59:00 | REVIEWS PLACED ON HOLD. SEE FRONT SCREEN NOTES. | | 2012-01-09 15:24:13 | **********************EXPEDITED********************* | | | C--25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2011-06-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-05-19 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2011-05-19 15:53:45 | *******************EXPEDITED******************** | | | B--7 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2012-02-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2012-02-28 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2012-02-28 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2012-02-28 14:27:14 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2012-06-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2012-06-25 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2012-06-25 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2012-06-27 12:42:50 | | | | | | | 1. SEE PREVIOUS COMMENT LIST REGARDING SHAFT. IT NOW | | | APPEARS THAT THE SHAFT HAS BEEN REMOVED FROM FLOOR | | | PLANS, BUT DOUBLE RECTANGLES DRAWN IN DASHED LINES | | | APPEAR ON THE MECHANICAL PLAN SHEETS FOR MEZZANINE AND | | | CATWALK. FOR INSTANCE, SEE SHEET M2-2, COLUMN LINE 2 | | | BETWEEN A AND B. PLEASE PROVIDE INFORMATION OR REMOVE. | | | | | | A HORIZONTAL SHAFT IS SHOWN ON A SHEETS, BUILDING | | | SECTIONS. PLEASE COORDINATE; MECHANICAL SHEETS DO NOT | | | SHOW A SHAFT, SEE FBC MECHANICAL 607.5.5. | | | | | | 2. FBC 2010 BUILDING 3006.2, SEE PREVIOUS COMMENT LIST, | | | NO ELEVATOR MACHINE ROOM SHOWN. IF A MRL ELEVATOR IS | | | PROPOSED, PLEASE SPECIFY ON MECHANICAL SHEETS OR ADVISE | | | WHERE THIS INFORMATION CAN BE FOUND ON THE PLAN IN | | | ORDER TO VERIFY THAT A SEPARATE, INDEPENDENT | | | VENTILATION SYSTEM IS NOT REQUIRED. PROVIDE | | | SPECIFICATIONS FOR THE ELEVATOR PROPOSED, FBC 107.1. | | | | | | 3. SEE PREVIOUS LIST, PROVIDE EITHER A CURB DETAIL OR | | | PROVIDE FLORIDA STATE OR LOCAL PRODUCT APPROVAL FOR | | | ROOF STANDS. DESIGNER IS TO SPECIFY DESIGN PRESSURES | | | FOR ROOFTOP EQUIPMENT, FBC BUILDING 301.12, FAC9N-3. | | | | | | 4. SEE PREVIOUS LIST, IF A SYSTEM SIZING SUMMARY IS | | | PROVIDED IN LIEU OF A FULL COOLING LOAD CALCULATION, IT | | | MUST BE SIGNED AND SEALED PER FBC BUILDING | | | 13-407.AB.1.1. | | | | | | 5. FIRE DAMPERS ARE MISSING AT THE FOLLOWING LOCATIONS; | | | 8X10 EXHAUST DUCTS (TWO LOCATIONS), M2-1, AND RISERS | | | BETWEEN FLOORS, EXHAUST THROUGH THE FLOOR M2-2. PLEASE | | | CHECK ALL REQUIRED LOCATIONS AND REVISE. FBC MECHANICAL | | | 607.6.3, 607.5.3. | | | | | | 6. LOCATION OF EXHAUST OUTLET NOT CLEAR, FBC MECHANICAL | | | 501.2.1. REVISE PLAN TO SHOW LOCATION. | | | | | | HAROLD MOSER, CHIEF MECHANICAL INSPECTOR | | | 561-805-6732 | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-06-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-06-17 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-06-15 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2011-06-17 15:52:40 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. DUCTS COMING FROM ROOF/SECOD FLOOR DOWN TO FIRST | | | FLOOR ARE SHOWN IN RATED SHAFT ENCLOSURES. DUCTS WHICH | | | PENETRATE SHAFT ENCLOSURES ARE REQUIRED TO BE PROTECTED | | | BY BOTH FIRE AND SMOKE DAMPERS PER FBC-M 607.5.5. FYI: | | | DUCTS THAT ONLY PENETRATE ONE FLOOR/CEILING ASSEMBLY | | | MAY NOT NEED A SHAFT ENCLOSURE AND COULD BE COMPLIANT | | | WITH A FIRE DAMPER PROTECTING THE PENETRATION AT THE | | | SECOND FLOOR SLAB. THIS WOULD ELIMINATE THE NEED FOR | | | SMOKE DAMPERS AND RATED SHAFTS. | | | | | | 2. AHU 1 AND AHU 2 ON MEZZANINE LEVEL SHARE A COMMON | | | RETURN AIR PLENUM. EACH UNIT IS REQUIRED TO HAVE DUCT | | | MOUNTED SMOKE DTECTORS ON BUTH THE SUPPLY AND RETURN IN | | | ACCORDANCE WITH FBC-M 606.2.2. | | | | | | 3. THE ELEVATOR MACHINE ROOM DOES NOT APPEAR ON THE | | | MECHANICAL FLOOR PLAN. HOW WILL THIS ROOM BE | | | VENTILATED? A SEPARATE, INDEPENDENT VENTILATION OR AIR | | | CONDITIONING SYSTEM IS REQUIRED FOR THE MACHINE ROOM | | | PER FBC-B 3006.2. | | | | | | 4. PAGE M2-1 SHOWS AHU-4 IN A CLOSET. NO SUCH APPLIANCE | | | APPEARS ON THE EQUIPMENT SCHEDULE (PAGE M3-3). PLEASE | | | COORDINATE SCHEDULES AND FLOOR PLANS. | | | | | | 5. ROOF PLAN SHOWS A PRE-ENGINEERED A/C STAND FOR | | | CONDENSING UNITS. PRODUCT APPROVAL IS REQUIRED PER FAC | | | RULE 9N-3. PROVIDE PRODUCT APPROVAL WHICH IS APPROVED | | | IN WRITING BY THE ENGINEER FOR THIS PROJECT PER FBC-M | | | 106.3.3. | | | | | | 6. IF A SYSTEM SIZING SUMMARY IS PROVIDED IN LIEU OF A | | | FULL COOLING LOAD CALCULATION, IT MUST BE SIGNED AND | | | SEALED PER FBC-B 13-407.AB.1.1. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2012-07-09 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-07-09 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-07-09 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2012-07-09 14:19:16 | FBC 2007 PLUMBING REVIEW #5 | | | DENIED: | | | | | | FROM LAST REVIEW: | | | | | | 2. THE SUMP PUMP SHOWN WILL BE REQUIRED TO CONNECT | | | INDIRECTLY (TO A FLOOR DRAIN OR HUB DRAIN) TO THE | | | **SANITARY** USING THE OIL SMART CONTROLS SHOWN ON | | | P3-1. | | | WITH THE USE OF THE OIL SMART CONTROLS, THE OIL | | | INTERCEPTOR WOULD NOT BE REQUIRED. | | | 301.6 PROHIBITED LOCATIONS. PLUMBING SYSTEMS SHALL NOT | | | BE LOCATED IN AN ELEVATOR SHAFT OR IN AN ELEVATOR | | | EQUIPMENT ROOM. | | | EXCEPTION: FLOOR DRAINS, SUMPS AND SUMP PUMPS SHALL BE | | | PERMITTED AT THE BASE OF THE SHAFT PROVIDED THEY ARE | | | ***INDIRECTLY*** CONNECTED TO THE PLUMBING SYSTEM. | | | THE SUMP LINE WILL NOT BE CONNECTED TO THE STORM SYSTEM | | | - CITY UTILITY CODE 90-203 (A) | | | | | | PLEASE CORRECT THE FOLLOWING: | | | | | | 1. WHILE SHEET P3-2 FIXTURE TABLE LISTS P-2 AS A | | | REGULAR WATER CLOSET P-3 AS A WALL HUNG LAV. | | | A. SHEET P2-2 SHOWS REGULAR WATER CLOSETS AS P-3 AND | | | WALL HUNG LAVS. AS P-2 | | | B. SHEET P3-3 SHOWS THE MEZZANINE A REGULAR WATER | | | CLOSET (2 WC'S ARE MISSING) AS P-3 AND 2 WALL HUNG LAVS | | | AS P-2 | | | C. SHEET P3-3 THE WATER PIPE ISO SHOWS 3 WC'S AS P-3 , | | | ALSO THE WALL HUNG LAVS APPEAR TO BE MISSING. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2012-04-25 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-04-25 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-04-25 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2012-04-25 14:46:58 | FBC 2007 PLUMBING REVIEW #4 | | | DENIED: | | | | | | FROM LAST REVIEW: | | | | | | 2. THE SUMP PUMP SHOWN WILL BE REQUIRED TO CONNECT | | | INDIRECTLY (TO A FLOOR DRAIN OR HUB DRAIN) TO THE | | | **SANITARY** USING THE OIL SMART CONTROLS SHOWN ON | | | P3-1. | | | WITH THE USE OF THE OIL SMART CONTROLS, THE OIL | | | INTERCEPTOR WOULD NOT BE REQUIRED. | | | 301.6 PROHIBITED LOCATIONS. PLUMBING SYSTEMS SHALL NOT | | | BE LOCATED IN AN ELEVATOR SHAFT OR IN AN ELEVATOR | | | EQUIPMENT ROOM. | | | EXCEPTION: FLOOR DRAINS, SUMPS AND SUMP PUMPS SHALL BE | | | PERMITTED AT THE BASE OF THE SHAFT PROVIDED THEY ARE | | | ***INDIRECTLY*** CONNECTED TO THE PLUMBING SYSTEM. | | | THE SUMP LINE WILL NOT BE CONNECTED TO THE STORM SYSTEM | | | - CITY UTILITY CODE 90-203 (A) | | | | | | PLEASE CORRECT THE FOLLOWING: | | | | | | 1. WHILE SHEET P3-2 FIXTURE TABLE LISTS P-2 AS A | | | REGULAR WATER CLOSET P-3 AS A WALL HUNG LAV. | | | A. SHEET P2-2 SHOWS REGULAR WATER CLOSETS AS P-3 AND | | | WALL HUNG LAVS. AS P-2 | | | B. SHEET P3-3 SHOWS THE MEZZANINE A REGULAR WATER | | | CLOSET (2 WC'S ARE MISSING) AS P-3 AND 2 WALL HUNG LAVS | | | AS P-2 | | | C. SHEET P3-3 THE WATER PIPE ISO SHOWS 3 WC'S AS P-3 , | | | ALSO THE WALL HUNG LAVS APPEAR TO BE MISSING. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2012-03-01 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-03-01 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-03-01 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2012-03-01 13:26:10 | FBC PLUMBING 2007 REVIEW #2 | | | DENIED: | | | | | | 1. THE LATEST SUBMITTED PLANS DATED 2/16/12 DO NOT | | | INCLUDE PLUMBING DRAWINGS. | | | | | | OLD P3-3 ISOMETRIC DRAWINGS DO NOT REFLECT THE NEW | | | P2-1- P2-2 PLUMBING DRAWINGS. NEW P3-3 ISOMETRICS WERE | | | NOT INCLUDED WITH RE-SUBMITTAL DRAWINGS. | | | | | | 2. THE SUMP PUMP SHOWN WILL BE REQUIRED TO CONNECT | | | INDIRECTLY (TO A FLOOR DRAIN OR HUB DRAIN) TO THE | | | **SANITARY** USING THE OIL SMART CONTROLS SHOWN ON | | | P3-1. | | | WITH THE USE OF THE OIL SMART CONTROLS, THE OIL | | | INTERCEPTOR WOULD NOT BE REQUIRED. | | | 301.6 PROHIBITED LOCATIONS. PLUMBING SYSTEMS SHALL NOT | | | BE LOCATED IN AN ELEVATOR SHAFT OR IN AN ELEVATOR | | | EQUIPMENT ROOM. | | | EXCEPTION: FLOOR DRAINS, SUMPS AND SUMP PUMPS SHALL BE | | | PERMITTED AT THE BASE OF THE SHAFT PROVIDED THEY ARE | | | INDIRECTLY CONNECTED TO THE PLUMBING SYSTEM. | | | THE SUMP LINE WILL NOT BE CONNECTED TO THE STORM SYSTEM | | | - CITY UTILITY CODE 90-203 (A) | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2012-03-01 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2012-01-11 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2012-01-11 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2012-01-11 11:21:53 | OWNER REMOVED PLANS. SEE FRONT SCREEN | | | | | | 1. OLD P-3.3 ISOMETRIC DRAWINGS DO NOT MATCH WITH NEW | | | PLUMBING DRAWINGS. NEW P-3.3 ISOMETRICS WERE NOT | | | INCLUDED WITH RE-SUBMITTAL DRAWINGS. | | | | | | 2. FIXTURE DESIGNATION NUMBERS ARE CROSSED. FOR EXAMPLE | | | - P-2 IS WC ON ONE PAGE AND LAV ON ANOTHER. | | | | | | 3. OCC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-05-27 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-05-27 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-05-24 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2011-05-24 08:28:32 | FBC PLUMBING 2007 REVIEW #1 | | | DENIED: | | | | | | MORE INFORMATION REQUESTED: | | | 1. SHEET A-1.0 BUILDING AND CODE INFORMATION CALLS FOR | | | OCCUPANCY A-2, BUT GIVES NO OCCUPANT LOAD. | | | THE NUMBER OF OCCUPANTS IS NEEDED FOR A FIXTURE COUNT. | | | THE 2ND FLOOR SHOWS NO FACILITIES. IN THAT CASE THE | | | FIXTURES ON THE MEZZANINE WOULD BE USED BY THE | | | OCCUPANTS ON THE 2ND FLOOR | | | | | | 2. MENS ADA RESTROOM ON SHEET A-41 DOES NOT MEET THE | | | REQUIREMENTS FOR 11-4.17.3 SIZE AND ARRANGEMENT. THE | | | SIZE AND ARRANGEMENT OF THE STANDARD TOILET STALL SHALL | | | COMPLY WITH FIGURE 30(A) | | | | | | 3. 403.7 UNISEX TOILET ROOM MAY, DEPENDING UPON FIXTURE | | | COUNT, BE REQUIRED. | | | 403.7 UNISEX TOILET AND BATHING ROOMS. IN ASSEMBLY AND | | | MERCANTILE OCCUPANCIES, AN ACCESSIBLE UNISEX TOILET | | | ROOM SHALL BE PROVIDED WHERE AN AGGREGATE OF SIX OR | | | MORE MALE AND FEMALE WATER CLOSETS IS REQUIRED. | | | | | | 4. SHEET P3-1 ELEVATOR SUMP PUMP DETAIL DOES NOT SHOW | | | THE SUMP PUMP OR PIPEING. FBC 3001.2 REFRENCED | | | STANDARDS ASME A17.1 WHERE DRAINS ARE NOT PROVIDED TO | | | PREVENT THE ACCUMULATION OF WATER, SUMP PUMPS SHALL BE | | | PROVIDED. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-06-01 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2011-06-01 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2011-06-01 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy