| Plan Review Stops For Permit 11050554 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-07-20 |
Time |
11:29 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2011-07-20 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-06-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-06-10 |
Time |
13:34 |
Rev Time |
2.20 |
| Received By |
jwitmer |
Date |
2011-06-10 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2011-06-10 13:34:19 | BUILDING PLAN REVIEW | | | PERMIT: 11050554 | | | ADD: 1601 BELVEDERE RD | | | CONT: TO BE DETERMINED | | | TEL: (561)###-#### | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | FRONT COUNTER TO VERIFY LICENSURE. | | | | | | 1) CONTRACTOR TO BE SIGNEDONTO THE PERMIT AND LICENSURE | | | VERIFIED BEFORE THE ISSUANCE OF PERMIT. | | | | | | PROVISOS: | | | 2) RECEPTION DESK A3.3 DETAILS 1A, 2A & 2C DO NOT | | | INDICATE COMPLIANCE WITH 2007/09 FBC-B 11-4-7. 2(2). | | | | | | 3) GUEST LAUNDRY A-1.6, A2.3 VENDING MACHINE LOCATED ON | | | WALL DOES NOT PROVIDE COMPLIANCE WITH 2007/09 FBC-B | | | 11-4.27 (1-4) . | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-06-21 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-06-21 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-06-20 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-07-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-07-25 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-07-25 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2011-06-15 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-06-15 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-06-15 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2011-06-15 11:26:09 | 1601 BELVEDERE ROAD | | | PERMIT #11050554 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SEPARATE PLANS AND PERMITS REQUIRED FOR FIRE ALARM AND | | | FIRE SPRINKLER WORK. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-08-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-08-10 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-07-18 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-08-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-06-20 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-05-18 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2011-05-18 15:53:04 | INCOMING SENT TO RON REGUEIRO DESK. JW |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-08-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-08-10 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-08-10 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-06-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-06-20 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-06-20 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2011-06-20 09:54:59 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PAGE M-2.2: DRYER EXHAUST IS SHOWN BEING ROUTED | | | THROUGH A RETURN AIR PLENUM CEILING SPACE. EXHAUST | | | TUCTS UNDER POSITIVE PRESSURE SHALL NOT PASS THROUGH A | | | PLENUM PER FBC-M 601.5. | | | | | | 2. PAGE M-2.2: PLAN SHOWS A DRYER BOOSTER FAN TO BE | | | USED. PROVIDE DRYER MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS SHOWING THAT A BOOSTER FAN MAY BE USED | | | WITH THESE SPECIFIC DRYERS. CLOTHES DRYERS SHALL BE | | | EXHAUSTED IN ACCORDANCE WITH THE DRYER MANUFACTURER'S | | | INSTRUCTIONS PER FBC-M 504.1. | | | | | | 3. PAGE M-2.2 SHOWS TWO DRYER EXHAUST DUCTS BEING | | | MANIFOLDED INTO ONE DUCT. NO DUCT SIZES ARE PROVIDED ON | | | PLAN. THIS CONDITION MUST ALSO BE COVERED BY THE DRYER | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS PER FBC-M | | | 504.1. | | | | | | 4. PAGE M-2.2: PLAN CALLS FOR DRYER EXHAUST TO | | | TERMINATE AT A GRS-8 ROOF VENT. WHERE WILL THE | | | BACKDRAFT DAMPER FOR THE DRYER EXHAUST BE LOCATED? IS | | | THE GRS-8 ROOF VENT OPENING SCREENED? BACKDRAFT DAMPER | | | IS REQUIRED ON DRYER EXHAUST DUCT OUTLETS AND SCREENS | | | ARE PROHIBITED PER FBC-M 504.4. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2011-06-20 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-06-20 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-06-08 |
Time |
11:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2011-08-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2011-08-22 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2011-08-22 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|