Plan Review Details - Permit 11050468
Plan Review Stops For Permit 11050468
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-02-03 Cont ID  
Sent By shill Date 2012-02-03 Time 11:44 Rev Time 0.00
Received By shill Date 2012-02-03 Time 09:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-10-20 Cont ID  
Sent By shill Date 2011-10-20 Time 10:21 Rev Time 0.00
Received By shill Date 2011-10-20 Time 10:21 Sent To  
Notes
2011-10-20 11:44:47****CORRECTIONS****
 (REVISED 11/7/11)
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 COMMENTS FROM PREVIOUS LIST:
  
 1. PROVIDE MORE INFORMATION REGARDING THE OCCUPANCY OF
 THIS BUILDING. SEE ZONING COMMENTS. IF A CHANGE OF
 OCCUPANCY IS INVOLVED, SHOW COMPLIANCE.
  
 2ND REVIEW, LETTER STATES THAT THERE IS NO BATHROOM OR
 KITCHEN, OWNER USING THE ADJACENT SPACE FOR STORAGE.
 HOWEVER, THERE IS A CURRENT BUSINESS TAX FOR APARTMENT,
 AND ARCHITECT'S PROPOSED SITE PLAN SHOWS THIS AS AN
 APARTMENT. IT APPEARS THAT A CHANGE OF OCCUPANCY WAS
 DONE WITHOUT PERMIT. PLEASE INCLUDE THE CONVERSION OF
 THE RESIDENTIAL SPACE TO STORAGE OCCUPANCY IN THE SCOPE
 OF THIS PERMIT. SEE FBC EXISTING BUILDING CODE FOR
 REQUIREMENTS FOR A CHANGE OF OCCUPANCY.
  
 COURTESY REVIEW 11/7/11 - PER ADDRESSING, THIS ADDRESS
 WAS IMPROPERLY USED BY ANOTHER ENTITY AND LOCATION.
 PLEASE CONSIDER THE COMMENT REGARDING CHANGE OF
 OCCUPANCY AS RESOLVED.
  
 2. REVISE EXPOSURE CATEGORY OR PROVIDE RATIONAL
 ANALYSIS CALCULATIONS FOR USE OF EXPOSURE B PRESSURES.
 FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE CHANGED
 EFFECTIVE MARCH 1, 2009.
  
 PLANS STILL STATE EXPOSURE B, PLEASE ADDRESS PREVIOUS
 COMMENT. DESIGN PRESSURES ON A4 TOO LOW FOR EXPOSURE C.
 LETTER REFERS TO SP1, CANNOT LOCATE THIS SHEET IN
 PERMIT PACKAGE.
  
 3. IMPACT PROTECTION REQUIRED,FBC1609.1.4, ALSO SEE
 ARCHITECT'S REQUIREMENTS ON SHEET A3. NON IMPACT
 PRODUCT APPROVALS SUBMITTED.
  
 2ND REVIEW, IMPACT PRODUCT APPROVALS SUBMITTED.
 HOWEVER, PLEASE NOTE THE FOLLOWING:\
  
 PGT FRENCH DOOR PRODUCT APPROVALS SUBMITTED, NOT CLEAR
 WHERE THIS WILL BE INSTALLED, AND THIS BRAND IS
 INTENDED FOR RESIDENTIAL USE AND DOES NOT COMPLY WITH
 THE REQUIREMENTS OF FBC CHAPTER 11 (SEE THRESHOLD
 HEIGHT ON PRODUCT APPROVAL, ALSO PER MANUFACTURER).
  
 4. SEE OTHER COMMENT REGARDING THE OCCUPANCY OF THIS
 BUILDING. PLANS STATE THAT THIS IS AN "EXISTING
 SHOWROOM" WHICH WOULD IMPLY MERCANTILE. NON IMPACT
 RESIDENTIAL DOOR PRODUCT APPROVAL WAS SUBMITTED.
 ARCHITECT HAS SPECIFIED PANIC BARS. THIS IS NOT
 INCLUDED IN THE PRODUCT APPROVAL. SILL HEIGHT ON THE
 DOOR PRODUCT APPROVAL EXCEEDS THE DIMENSION PERMITTED
 BY FBC11-4.5.2, PRODUCT APPROVAL DOES NOT INCLUDE PANIC
 BARS.
  
 IT APPEARS THAT PROPOSED USE (OR PERHAPS EXISTING USE,
 DONE WITHOUT PERMIT) IS MERCANTILE, BUSINESS, AND
 STORAGE. REVISE PLAN TO SHOW COMPLIANCE WITH CHANGE OF
 OCCUPANCY FROM RESIDENTIAL TO STORAGE, SEE OTHER
 COMMENTS. SEE FBC EXISTING BUILDING CHAPTER 9. IF YOU
 BELIEVE THAT A CHANGE OF OCCUPANCY WAS DONE PREVIOUSLY
 THROUGH THE BUILDING DEPARTMENT AS REQUIRED BY FBC
 105.1, PLEASE PROVIDE DOCUMENTATION (PERMIT NUMBER) AND
 EXPLAIN THE APARTMENT BUSINESS TAX RECEIPT (FORMERLY
 CALLED "OCCUPATIONAL LICENSE") FOR THIS STRUCTURE.
  
 COURTESY REVIEW 11/7/11 - PER ARCHITECT, BUILDING IS
 EXISTING; MERCANTILE, BUSINESS, AND STORAGE.
  
 5-7. ADDRESSED.
  
 NEW COMMENTS:
  
 8. SLIDING DOORS ARE NOW SHOWN IN THE PLAN, SHOW
 COMPLIANCE WITH FBC1008.1.3.3. THE SLIDING GLASS DOOR
 PRODUCT APPROVAL IS A RESIDENTIAL DOOR, PLEASE SUBMIT
 APPROPRIATE PRODUCT APPROVAL.
  
 9. AS NO MECHANICAL INFORMATION WAS PROVIDED,
 MECHANICAL REVIEW WILL NOT BE DONE ON THIS REVIEW.
 PLEASE PROVIDE INFORMATION TO SHOW COMPLIANCE WITH FBC
 EXISTING BUIDLING 709.1 AND 909 (EXHAUST FOR BATHROOMS,
 VENTILATION (OUTDOOR AIR) FBC MECHANICAL CHAPTER 4).
  
 COURTESY REVIEW 11/7/11, N/A (PLEASE DISREGARD #9)
  
 10. PROVIDE A DETAIL FOR THE RAMP, FBC 11-4.8. ALSO SEE
 MANEUVERING CLEARANCE FOR DOORS, FBC 11 FIGURE 25 AND
 REVISE PLAN TO SHOW MINIMUM DIMENSIONS.
  
 11. PROVIDE A COST BREAKDOWN FOR THIS JOB, SEE FBC
 11-4.1.6(2).
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-06-02 Cont ID  
Sent By shill Date 2011-06-02 Time 14:20 Rev Time 0.00
Received By shill Date 2011-06-02 Time 14:20 Sent To  
Notes
2011-06-02 14:42:14****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PROVIDE MORE INFORMATION REGARDING THE OCCUPANCY OF
 THIS BUILDING. SEE ZONING COMMENTS. IF A CHANGE OF
 OCCUPANCY IS INVOLVED, SHOW COMPLIANCE.
  
 2. REVISE EXPOSURE CATEGORY OR PROVIDE RATIONAL
 ANALYSIS CALCULATIONS FOR USE OF EXPOSURE B PRESSURES.
 FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE CHANGED
 EFFECTIVE MARCH 1, 2009.
  
 3. IMPACT PROTECTION REQUIRED,FBC1609.1.4, ALSO SEE
 ARCHITECT'S REQUIREMENTS ON SHEET A3. NON IMPACT
 PRODUCT APPROVALS SUBMITTED.
  
 4. SEE OTHER COMMENT REGARDING THE OCCUPANCY OF THIS
 BUILDING. PLANS STATE THAT THIS IS AN "EXISTING
 SHOWROOM" WHICH WOULD IMPLY MERCANTILE. NON IMPACT
 RESIDENTIAL DOOR PRODUCT APPROVAL WAS SUBMITTED.
 ARCHITECT HAS SPECIFIED PANIC BARS. THIS IS NOT
 INCLUDED IN THE PRODUCT APPROVAL. SILL HEIGHT ON THE
 DOOR PRODUCT APPROVAL EXCEEDS THE DIMENSION PERMITTED
 BY FBC11-4.5.2, PRODUCT APPROVAL DOES NOT INCLUDE PANIC
 BARS.
  
 5. PLEASE PROVIDE A SITE PLAN TO SHOW LOCATION OF
 PROPOSED IMPROVEMENTS IN RELATION TO THE PROPERTY LINE.
 A COMPLETE PLAN REVIEW CANNOT BE PERFORMED AT THIS
 TIME.
  
 6. PLEASE REVISE PLAN TO SHOW WHETHER A1 IS "PROPOSED
 FLOOR PLAN" OR "EXISTING FLOOR PLAN." IF THIS IS
 "PROPOSED," IT IS NOT CLEAR HOW PANIC HARDWARE WILL
 OPERATE ON AN INSWING DOOR.
  
 7. DOOR HARDWARE TO COMPLY WITH FBC1008.1.4, PLEASE
 PROVIDE SPECS TO SHOW COMPLIANCE IF NOT INCLUDED IN THE
 PRODUCT APPROVAL.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2012-01-30 Cont ID  
Sent By rlecky Date 2012-01-30 Time 12:45 Rev Time 0.00
Received By rlecky Date 2012-01-30 Time 12:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2011-10-26 Cont ID  
Sent By rlecky Date 2011-10-26 Time 16:55 Rev Time 0.00
Received By rlecky Date 2011-10-26 Time 16:51 Sent To  
Notes
2011-10-26 16:56:46NO ELECTRICAL SHOWN. DEPENDING ON THE FUTURE OCCUPANCY
 TYPE CHANGES MAY BE REQUIRED TO THE EXISTING ELECTRICAL
 SYSTEM.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2012-06-08 Cont ID  
Sent By wjolin Date 2012-06-08 Time 13:28 Rev Time 0.00
Received By wjolin Date 2012-06-08 Time 13:28 Sent To Z
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2012-01-27 Cont ID  
Sent By wjolin Date 2012-01-27 Time 10:42 Rev Time 0.00
Received By wjolin Date 2012-01-27 Time 09:56 Sent To  
Notes
2012-01-27 10:42:462417 SPRUCE AVENUE
 PERMIT #11050468
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 ANY AREA (STORAGE) HAVING A DEGREE OF HAZARD GREATER
 THAN NORMAL TO THE GENERAL OCCUPANCY (MERCANTILE) OF
 THE BUILDING, SHALL BE SEPARATED FROM NON-STORAGE AREAS
 WITH A 1-HOUR FIRE-RATED BARRIER. DOORS SHALL BE SELF
 CLOSING, POSITIVE LATCHING, AND FIRE-RATED FOR AT LEAST
 45-MINUTES PER SECTION 8.7 OF NFPA 101.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2011-10-25 Cont ID  
Sent By wjolin Date 2011-10-25 Time 14:13 Rev Time 0.00
Received By wjolin Date 2011-10-25 Time 14:01 Sent To  
Notes
2011-10-25 14:13:502417 SPRUCE AVENUE
 PERMIT #11050468
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE ADDRESS ON THE PLANS DOES NOT MATCH THE ADDRESS ON
 THE PERMIT APPLICATION.
  
 CONFIRM EXISTING BUILDING ADDRESS VISIBLE FROM THE
 STREET. NUMBERS SHALL BE ATTACHED TO THE BUILDING AND
 BE AT LEAST SIX-INCHES IN HEIGHT WITH 1-INCH STROKE AND
 SHALL CONTRAST THE BACKGROUND (REFERENCE: SECTION
 10.12.1.2 OF THE FLORIDA FIRE PREVENTION CODE ? NFPA
 1).
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-02-03 Cont ID  
Sent By lwagner Date 2012-02-03 Time 13:58 Rev Time 0.00
Received By lwagner Date 2012-01-17 Time 13:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-10-26 Cont ID  
Sent By rlecky Date 2011-10-26 Time 16:59 Rev Time 0.00
Received By rlecky Date 2011-09-27 Time 10:35 Sent To  
Notes
2011-09-27 10:36:27SENT TO B1 SHELF FOR ERIC'S AND SAMANTHA'S REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-06-02 Cont ID  
Sent By shill Date 2011-06-02 Time 14:42 Rev Time 0.00
Received By shill Date 2011-05-17 Time 12:50 Sent To  
Notes
2011-05-17 12:50:59TO ZONING
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2012-01-31 Cont ID  
Sent By hmoser Date 2012-01-31 Time 08:15 Rev Time 0.00
Received By hmoser Date 2012-01-31 Time 08:00 Sent To  
Notes
2012-01-31 08:18:25APPLICATION STATES RENOVATION OF WINDOWS AND DOORS
 MECHANICAL NOT REQUIRED.
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-10-20 Cont ID  
Sent By shill Date 2011-10-20 Time 11:45 Rev Time 0.00
Received By shill Date 2011-10-20 Time 11:45 Sent To  
Notes
2011-10-20 11:45:43NO MECHANICAL PLANS SUBMITTED; PROVIDE PLAN WHICH SHOWS
 COMPLIANCE WITH CHANGE OF OCCUPANCY AND LEVEL 2
 ALTERATION FOR NEXT REVIEW
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2012-02-03 Cont ID  
Sent By lwagner Date 2012-02-03 Time 13:12 Rev Time 0.00
Received By lwagner Date 2012-01-27 Time 11:01 Sent To  
Notes
2012-02-03 13:14:58EXISTING BUILDING - NO PLUMBING

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-10-21 Cont ID  
Sent By lwagner Date 2011-10-21 Time 13:17 Rev Time 0.00
Received By lwagner Date 2011-10-21 Time 12:58 Sent To  
Notes
2011-10-21 13:19:021. UNABLE TO REVIEW FOR PLUMBING AT THIS TIME. PLUMBING
 FIXTURES REQUIREMENTS ARE BASED UPON OCCUPANCY TYPE AND
 OCCUPANT LOAD.
 FROM NOTE #1 BUILDING - 1. PROVIDE MORE INFORMATION
 REGARDING THE OCCUPANCY OF THIS BUILDING. SEE ZONING
 COMMENTS. IF A CHANGE OF OCCUPANCY IS INVOLVED, SHOW
 COMPLIANCE.
  
 2. CHANGE OF OCCUPANCY WOULD REQUIRE FIXTURE COMPLIANCE
 WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE
 FBC EXISTING BUILDING CODE SECTION 906
 ACCESSIBILITY
  
 906.1 GENERAL. ACCESSIBILITY IN PORTIONS OF BUILDINGS
 UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL
 COMPLY WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE,
 BUILDING .

Review Stop Z ZONING
Rev No 4 Status P Date 2012-06-12 Cont ID  
Sent By eschneid Date 2012-06-12 Time 10:06 Rev Time 1.00
Received By eschneid Date 2012-06-08 Time 15:41 Sent To  
Notes
2012-06-12 10:07:43CONDITIONAL PERMIT - THE INSTALLATION OF LANDSCAPE PER
 AN APPROVED LANDSCAPE PERMIT IS REQUIRED.
  
  

Review Stop Z ZONING
Rev No 3 Status F Date 2012-01-24 Cont ID  
Sent By eschneid Date 2012-01-24 Time 08:40 Rev Time 1.50
Received By eschneid Date 2012-01-23 Time 16:30 Sent To  
Notes
2012-01-24 09:22:17FAILED
  
 1) REPEAT COMMENT - THE NORTHWOOD MIXED USE DISTRICT
 REQUIRES ALL SURFACE PARKING LOTS SHALL BE LANDSCAPED
 WITH A STREET FRONT HEDGE AT THREE FEET SIX INCHES IN
 HEIGHT AND SHADE TREES AT EVERY THIRD PARKING SPACE
 ALONG THE SIDEWALK. SHRUBS SHALL BE PLANTED AT TWO-FOOT
 INTERVALS. THE AREAS ALONG SPRUCE AVE. AND 24TH ST.
 THAT ARE NOT PART OF THE DRIVEWAY SHALL MEET THIS
 REQUIREMENT. A LANDSCAPE PERMIT SHALL BE SUBMITTED FOR
 REVIEW PRIOR TO ZONING APPROVAL OF THIS PERMIT. PLEASE
 NOTE THAT THE CRA IMPROVEMENTS TO SPRUCE AVE. AND 24TH
 STREET WERE ONLY IN THE RIGHT-OF-WAY AND DO NOT ABSOLVE
 THE PROPERTY OWNER FROM COMPLYING WITH THE NMUD
 REGULATIONS. KELLY FREEMAN HAS CONVEYED THIS TO THE
 PROPERTY OWNER.
  
 2) SIGNAGE WILL REQUIRE A SEPARATE PERMIT.
  
 CONTACT ERIC SCHNEIDER (561) 822-1446.
  

Review Stop Z ZONING
Rev No 2 Status F Date 2011-10-13 Cont ID  
Sent By eschneid Date 2011-10-13 Time 18:57 Rev Time 1.00
Received By eschneid Date 2011-10-13 Time 18:09 Sent To  
Notes
2011-10-13 18:55:35FAILED
  
 1) REPEAT COMMENT - THE NORTHWOOD MIXED USE DISTRICT
 HAS MINIMUM GLAZING REQUIREMENTS. PLEASE PROVIDE THE
 GLAZING CALCULATIONS BETWEEN 2 AND 8 FEET ("STOREFRONT
 AREA") FOR THE ENTIRE SPRUCE AVENUE AND 24TH STREET
 FACADES. THE CALCULATIONS ON SHEET A-2.1 ONLY INCLUDE A
 SOUTHERN PORTION OF THE FACADE, IT SHALL INCLUDE THE
 ENTIRE EASTERN FACADE. NOTE - THE CALCULATIONS FOR THE
 SQUARE FOOTAGE IS THE SAME IN BOTH AND SHALL BE
 CORRECTED. NO SHEET IS PROVIDED FOR THE NORTH FACADE.
 THE GLAZING CALCULATIONS SHALL INCLUDE THE EXISTING AND
 PROPOSED CONDITIONS.
  
 2) REPEAT COMMENT - THE NORTHWOOD MIXED USE DISTRICT
 REQUIRES ALL SURFACE PARKING LOTS SHALL BE LANDSCAPED
 WITH A STREET FRONT HEDGE AT THREE FEET SIX INCHES IN
 HEIGHT AND SHADE TREES AT EVERY THIRD PARKING SPACE
 ALONG THE SIDEWALK. SHRUBS SHALL BE PLANTED AT TWO-FOOT
 INTERVALS. THE AREAS ALONG SPRUCE AVE. AND 24TH ST.
 THAT ARE NOT PART OF THE DRIVEWAY SHALL MEET THIS
 REQUIREMENT. A LANDSCAPE PERMIT SHALL BE SUBMITTED FOR
 REVIEW PRIOR TO ZONING APPROVAL OF THIS PERMIT.
  
 3) SIGNAGE WILL REQUIRE A SEPARATE PERMIT.
  
 CONTACT ERIC SCHNEIDER (561) 822-1446.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2011-05-25 Cont ID  
Sent By eschneid Date 2011-05-25 Time 13:33 Rev Time 3.00
Received By eschneid Date 2011-05-18 Time 14:45 Sent To  
Notes
2011-05-25 13:49:01FAILED
  
 1) THE BUILDING APPEARS TO BE CONSTRUCTED AT THE
 PROPERTY LINE ALONG SPRUCE AVENUE AND THE ALLEY. THE
 PLANS SHOW ARCHITECTURAL ELEMENTS THAT WILL EXTEND FROM
 THE FACADE OF THE BUILDING. PLEASE PROVIDE A RECENT
 SURVEY, LESS THAN ONE YEAR OLD, SHOWING THE BUILDING
 AND THE DIMENSION TO ALL PROPERTY LINES.
  
 2) THE INFORMATION PROVIDED ON THE SURVEY, TAKEN WITH
 THE PROPOSED FACADE TREATMENTS, MAY REQUIRE
 RIGHT-OF-WAY PERMITS IF ANY ENCROACHMENTS ARE
 IDENTIFIED.
  
 3) THE ACTIVE BUSINESS TAX RECEIPTS FOR THE SITE ARE
 FOR A RETAIL BUSINESS (BIRDS OFF BROADWAY) AND AN
 APARTMENT. NEITHER OF THESE IS INDICATED ON THE FLOOR
 PLAN. PLEASE INDICATE WHERE THESE USES ARE LOCATED
 WITHIN THE BUILDING.
  
 4) DOES THIS PERMIT INCLUDE INTERIOR RENOVATIONS?
  
 5) THE NORTHWOOD MIXED USE DISTRICT LIMITS EXTERIOR
 FINISH MATERIAL TO STONE, BRICK, STUCCO, EXPOSED
 CONCRETE, TERRA COTTA TILE, CERAMIC TILE, ANY STONE
 CLADDING MATERIAL-MARBLE, LIMESTONE, GRANITE, PRECAST
 CONCRETE, CLAPBOARD SIDING, AND WOOD SHINGLES. PLEASE
 DESCRIBE WHAT THE COMPOSITE MATERIAL SHOWN ON THE PLANS
 IS AND WHICH CATEGORY IT FITS INTO.
  
 6) THE NORTHWOOD MIXED USE DISTRICT LIMITS EXTERIOR
 FINISH MATERIAL TO NO MORE THAN TWO ON A WALL. THE EAST
 ELEVATION SHOWS THE COMPOSITE MATERIAL, STUCCO AND
 TILE. THIS IS 3 DIFFERENT MATERIALS.
  
 7) THE NORTHWOOD MIXED USE DISTRICT HAS MINIMUM GLAZING
 REQUIREMENTS. PLEASE PROVIDE THE GLAZING CALCULATIONS
 BETWEEN 2 AND 8 FEET ("STOREFRONT AREA") FOR THE SPRUCE
 AVENUE AND 24TH STREET FACADES. THE GLAZING
 CALCULATIONS SHALL INCLUDE THE EXISTING AND PROPOSED
 CONDITIONS. PLEASE NOTE THAT IF THE CURRENT GLAZED AREA
 EXCEEDS 50 PERCENT OF THE STOREFRONT AREA, IT MAY NOT
 BE REDUCED AND IF IT IS CURRENTLY LESS THAN 50 PERCENT
 OF THE STOREFRONT AREA IT SHALL BE INCREASED TO 50
 PERCENT.
  
 8) THE NORTHWOOD MIXED USE DISTRICT REQUIRES WINDOWS TO
 BE RECESSED A MINIMUM OF TWO INCHES FROM THE EXTERIOR
 FACE OF THE FACADE. PLEASE PROVIDE VERIFICATION THAT
 THE NEW WINDOWS MEET THIS REQUIREMENT.
  
 9) THE NORTHWOOD MIXED USE DISTRICT REQUIRES THAT
 MULTIPLE WINDOWS IN THE SAME ROUGH OPENING BE SEPARATED
 BY A FOUR-INCH WIDE POST AND SIT ON ONE CONTINUOUS
 SILL. PLEASE PROVIDE THE DIMENSION TO VERIFY THAT THE
 WINDOWS IN THE SAME OPENING ON THE NORTH SIDE OF THE
 BUILDING MEET THIS REQUIREMENT.
  
 10) THE NORTHWOOD MIXED USE DISTRICT REQUIRES AWNINGS
 AT THE SIDEWALK LEVEL SHALL PROJECT A MINIMUM OF FOUR
 FEET FROM THE BUILDING FACADE AND HAVE A MINIMUM OF
 NINE FEET IN CLEARANCE FROM THE SIDEWALK LEVEL TO THE
 BOTTOM OF THE AWNING. NEITHER OF THESE STANDARDS IS MET
 FOR THE PROPOSED AWNINGS. ADDITIONALLY, A RIGHT-OF-WAY
 PERMIT IS REQUIRED FOR THE AWNING PROJECTION OVER
 SPRUCE AVENUE.
  
 11) THE NORTHWOOD MIXED USE DISTRICT REQUIRES
 MECHANICAL SYSTEMS TO BE SCREENED FROM VIEW BY
 LANDSCAPING OR BUILT ELEMENTS DESIGNED AS AN INTEGRAL
 PART OF THE BUILDING ARCHITECTURE. THERE APPEARS TO BE
 AN A/C UNIT IN THE PARKING LOT. THIS NEEDS TO BE
 SCREENED IN ACCORDANCE WITH THE REGULATIONS. ANY NEW
 EQUIPMENT ALSO NEEDS TO BE SCREENED.
  
 12) THE AWNINGS AND ANY SIGNAGE WILL REQUIRE A SEPARATE
 PERMIT.
  
 13) THE NORTHWOOD MIXED USE DISTRICT REQUIRES ALL
 SURFACE PARKING LOTS SHALL BE LANDSCAPED WITH A STREET
 FRONT HEDGE AT THREE FEET SIX INCHES IN HEIGHT AND
 SHADE TREES AT EVERY THIRD PARKING SPACE ALONG THE
 SIDEWALK. SHRUBS SHALL BE PLANTED AT TWO-FOOT
 INTERVALS. THE AREAS ALONG SPRUCE AVE. AND 24TH ST.
 THAT ARE NOT PART OF THE DRIVEWAY SHALL MEET THIS
 REQUIREMENT.
  
 CONTACT ERIC SCHNEIDER (561) 822-1446.
  