Plan Review Details - Permit 11050433
| Plan Review Stops For Permit 11050433 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-08-30 |
Time |
17:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-30 |
Time |
17:43 |
Sent To |
|
|
| Notes |
| 2011-08-30 17:43:53 | PROVIDE COMPLETED INSTALLATION SCHEDULE AT INSPECTION | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-06-27 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-06-27 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2011-06-27 10:46:14 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PRESSURES ARE TOO LOW. REVISE EXPOSURE TO CATEGORY C | | | OR PROVIDE RATIONAL ANALYSIS FOR REDUCED PRESSURES. | | | FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE CHANGED | | | EFFECTIVE MARCH 1, 2009. | | | | | | 2. SPANS ARE NOT CORRECT; WITH A WALL MOUNT, THIS | | | SHOULD BE LARGER THAN THE OPENING DIMENSION. SPAN FOR | | | ACCORDION SHUTTERS SHOULD EQUAL THE BLADE LENGTH. | | | | | | 3. EITHER REVISE BOTTOM SUBSTRATE TO BLOCK OR PROVIDE | | | INFORMATION AS TO HOW YOU HAVE DETERMINED THAT THE | | | BOTTOM SUBSTRATE IS CONCRETE. CBS HOMES TYPICALLY HAVE | | | CONCRETE TOP, BLOCK BOTTOM SUBSTRATE. A FILLED CELL | | | REQUIRES USE OF BLOCK SUBSTRATE UNLESS THE PRODUCT | | | APPROVAL INCLUDES FILLED CMU AS A SUBSTRATE. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU NEED ASSISTANCE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-05-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-05-19 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-05-19 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2011-05-19 14:00:28 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | | INSTALLATION.PDF | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-08-25 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2011-08-25 14:11:26 | TO SH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-06-27 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-06-26 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2011-06-26 10:18:03 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-05-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-05-19 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-05-17 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2011-05-17 12:52:04 | TO BLDG < $5K |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |