Plan Review Details - Permit 11050388
Plan Review Stops For Permit 11050388
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2011-08-22 Cont ID  
Sent By rmcdouga Date 2011-08-22 Time 12:08 Rev Time 0.00
Received By rmcdouga Date 2011-08-22 Time 12:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2011-08-17 Cont ID  
Sent By rmcdouga Date 2011-08-17 Time 07:11 Rev Time 0.00
Received By rmcdouga Date 2011-08-17 Time 07:11 Sent To  
Notes
2011-08-17 07:32:472007 FBC W/2009 REVISIONS
  
 1) SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE
 STRUCTURE AS REQUIRED BY FBCR N1100.3.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2011-08-03 Cont ID  
Sent By rmcdouga Date 2011-08-03 Time 09:39 Rev Time 0.00
Received By rmcdouga Date 2011-08-03 Time 07:29 Sent To  
Notes
2011-08-03 09:39:282007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) PROVIDE TWO COPIES OF A SURFACE WATER DRAINAGE PLAN
 SHOWING COMPLIANCE WITH FBC R401.3. THE SURVEY DOES NOT
 ADDRESS SURFACE WATER DRAINAGE OR SHOW COMPLIANCE WITH
 FBC R401.3.
  
 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE
 STRUCTURE AS REQUIRED BY FBCR N1100.3.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-06-24 Cont ID  
Sent By rmcdouga Date 2011-06-24 Time 10:17 Rev Time 0.00
Received By rmcdouga Date 2011-06-24 Time 10:17 Sent To  
Notes
2011-06-24 11:28:262007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF A SURVEY/SITE PLAN SHOWING THE
 LOCATION OF THE PROPOSED STRUCTURE ON THE LOT AND THE
 DISTANCES TO THE PROPERTY LINES. FBC R302.1
  
 2) PROVIDE TWO COPIES OF A SURFACE WATER DRAINAGE PLAN
 SHOWING COMPLIANCE WITH FBC R401.3.
  
 3) SHOW COMPLIANCE WITH FBC R 403.1.4 WHICH REQUIRES
 ALL EXTERIOR FOOTINGS TO BE AT LEAST 12 INCHES BELOW
 GRADE.
  
 4) SUBMIT TWO SETS OF ENERGY CALCULATIONS FORMS FOR THE
 STRUCTURE AS REQUIRED BY FBCR N1100.3.
  
 5) PROVIDE WINDOW AND DOOR BUCK FASTENING DETAILS
 COMPLYING WITH FBC R613.6.1.1.
  
 6) SHOW COMPLIANCE WITH FBC R3I3 FOR REQUIRED SMOKE
 ALARMS.
  
 7) THE DESIGNER OF RECORD FOR THE STRUCTURE IS REQUIRED
 TO REVIEW AND APPROVE THE PRODUCT APPROVALS IN WRITING.
 CITY AMENDMENTS 106.3.3
  
 8) THE STRUCTURE IS LOCATED WITHIN 1500 FEET OF THE
 INTRACOASTAL WATERWAY WHICH MAKES THE EXPOSURE CATEGORY
 C. PLEASE CORRECT SHEET 3 AND REVISE THE REQUIRED
 WINDOW AND DOOR DESIGN LOADS ON SHEET 2.
  
 9) FBC R803.2.3.1 REQUIRES ROOF SHEATHING FASTENER
 SPACING TO BE 6" OC IN THE FIELD AS WELL AS THE EDGES.
 PLEASE REVISE NOTES ON SHEET 4.
  
 10) THE VALUE OF THE PROJECT HAS BEEN INCREASED FROM
 $125,000.00 TO $129,922.00 BASED ON THE CURRENT ICC
 VALUATION DATA TABLES. CITY AMENDMENTS 108.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-06-02 Cont ID  
Sent By rmcdouga Date 2011-06-02 Time 11:26 Rev Time 0.00
Received By rmcdouga Date 2011-06-03 Time 07:20 Sent To  
Notes
2011-06-02 15:05:582007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF A SURVEY/SITE PLAN SHOWING THE
 LOCATION OF THE PROPOSED STRUCTURE ON THE LOT AND THE
 DISTANCES TO THE PROPERTY LINES. FBC R302.1
  
 2) PROVIDE TWO COPIES OF A SURFACE WATER DRAINAGE PLAN
 SHOWING COMPLIANCE WITH FBC R401.3.
  
 3) SHOW COMPLIANCE WITH FBC R 602.1.2 (1) - (4) FOR
 FIRE BLOCKING. SEVERAL OF THE CROSS SECTION DRAWINGS ON
 THE PLANS HAVE AREAS THAT REQUIRE FIRE BLOCKING
 INCLUDING THE STAIRS.
  
 4) SHOW COMPLIANCE WITH FBC R703.6.3 WHICH REQUIRES A
 BOND BREAK BETWEEN THE REQUIRED WATER-RESISTIVE BARRIER
 (R703.2) AND THE STUCCO.
  
 5) SHOW COMPLIANCE WITH FBC R320.7 WHICH REQUIRES
 DOWNSPOUTS TO DISCHARGE AT LEAST 1 FOOT AWAY FROM THE
 STRUCTURE.
  
 6) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 EXTERIOR DOORS, WINDOWS, ROOFING MATERIAL, STORM
 PANELS, AND PANEL WALLS AS REQUIRED BY DCA RULE 9N-3.
  
 7) SUBMIT SHOP DRAWINGS FOR THE PANEL WALLS THAT HAVE
 BEEN REVIEWED AND ACCEPTED BY THE DESIGNER OF RECORD OF
 THE STRUCTURE.
  
 8) SHOW COMPLIANCE WITH FBC R312 FOR THE STAIR AND
 LANDING GUARD HEIGHTS AND OPENING LIMITATIONS.
  
 9) SHOW COMPLIANCE WITH FBC R806 FOR ROOF VENTILATION.
  
 10) PLEASE PROVIDE A RESPONSE LETTER INDICATING HOW
 EACH OF THE REVIEW COMMENTS HAVE BEEN ADDRESSED.
  
 11) THE VALUE OF THE PROJECT HAS BEEN INCREASED FROM
 $125,000.00 TO $274,638.00 BASED ON THE CURRENT ICC
 VALUATION DATA TABLES. CITY AMENDMENTS 108.3
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2011-07-27 Cont ID  
Sent By rlecky Date 2011-07-27 Time 12:28 Rev Time 0.00
Received By rlecky Date 2011-07-27 Time 12:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2011-06-20 Cont ID  
Sent By rlecky Date 2011-06-20 Time 13:59 Rev Time 0.00
Received By rlecky Date 2011-06-20 Time 13:40 Sent To  
Notes
2011-06-20 14:00:21 
 PLEASE REVISE THE PLAN TO INCLUDE THE FOLLOWING:
 ADDITIONAL RECEPTACLES REQUIRED IN THE BEDROOMS AND
 HALLWAY. ADD RECEPTACLES SO THAT NO WALL SPACE IS MORE
 THAN 6 FEET FROM A RECEPTACLE AND ALL WALL SPACES MORE
 THAN 2 FEET IN WIDTH HAVE A RECEPTACLE. NEC 210.52
 PROVIDE INTERCONNECTED SMOKE DETECTORS WITH BATTERY
 BACKUP INSIDE AND OUTSIDE ALL SLEEPING AREAS. FBC
 R313.2
 PROVIDE AN INTERSYSTEM BONDING STRIP AT THE SERVICE
 GROUND. NEC 250.94
 RECEPTACLES MUST BE ARC FAULT CIRCUIT PROTECTED AND
 TAMPER RESISTANT. NEC 406.11, NEC 210-12 (B)
 PROVIDE A 20 AMP BRANCH CIRCUIT FOR THE BATHROOMS. NEC
 210.11 (C)(3)
 VERIFY THE AVAILABLE FAULT CURRENT AT THE ELECTRIC
 SERVICE IS LESS THAN 10,000 AIC. NEC 110.9
 PROVIDE ACCESS AND SAFETY CLEARANCES IN FRONT AND SIDE
 TO SIDE AT THE ELECTRICAL PANEL BOARD. NEC 110.26
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-06-01 Cont ID  
Sent By rlecky Date 2011-05-25 Time 10:22 Rev Time 0.00
Received By rlecky Date 2011-05-25 Time 10:18 Sent To  
Notes
2011-06-01 10:22:34ADDITIONAL RECEPTACLES REQUIRED IN THE ENTRANCE HALL
 WAY, EAST HALL AND ON WEST WALL. ADD RECEPTACLES SO
 THAT NO WALL SPACE IS MORE THAN 6 FEET FROM A
 RECEPTACLE AND ALL WALL SPACES MORE THAN 2 FEET IN
 WIDTH HAVE A RECEPTACLE. ADDITIONAL RECEPTACLES
 REQUIRED ON BOTH FLOORS. NEC 210.52
 KITCHEN RECEPTACLES SERVING THE COUNTER TOP SURFACES
 MUST BE GFCI PROTECTED. NEC 210.8
 PROVIDE INTERCONNECTED SMOKE DETECTORS WITH BATTERY
 BACKUP INSIDE AND OUTSIDE ALL SLEEPING AREAS. FBC
 R313.2
 PROVIDE AN INTERSYSTEM BONDING STRIP AT THE SERVICE
 GROUND. NEC 250.94
 RECEPTACLES MUST BE ARC FAULT CIRCUIT PROTECTED AND
 TAMPER RESISTANT. NEC 406.11, NEC 210-12 (B)
 PROVIDE A BRANCH CIRCUIT FOR THE BATHROOMS. NEC 210.11
 (C)(3)
 VERIFY THE AVAILABLE FAULT CURRENT AT THE ELECTRIC
 SERVICE IS LESS THAN 10,000 AIC. NEC 110.9
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2011-08-17 Cont ID  
Sent By rmcdouga Date 2011-08-17 Time 08:01 Rev Time 0.00
Received By rmcdouga Date 2011-08-16 Time 15:23 Sent To  
Notes
2011-08-16 15:29:46TO ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-08-22 Cont ID  
Sent By rlecky Date 2011-08-15 Time 15:27 Rev Time 0.00
Received By rmcdouga Date 2011-07-22 Time 17:21 Sent To  
Notes
2011-07-22 17:22:30************EXPEDITED************
 R--13

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-07-22 Cont ID  
Sent By lmartine Date 2011-07-09 Time 17:20 Rev Time 0.00
Received By lmartine Date 2011-06-20 Time 08:07 Sent To  
Notes
2011-06-20 08:08:07***** EXPEDITED 2ND RUN *****
 R13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-06-20 Cont ID  
Sent By shill Date 2011-06-02 Time 08:07 Rev Time 0.00
Received By shill Date 2011-05-13 Time 10:17 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2011-08-23 Cont ID  
Sent By rmcdouga Date 2011-08-23 Time 14:36 Rev Time 0.00
Received By rmcdouga Date 2011-08-23 Time 14:36 Sent To  
Notes
2011-08-23 14:38:02EXISTING USE CREDIT. NO FEES DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2011-06-02 Cont ID  
Sent By rmcdouga Date 2011-06-02 Time 11:23 Rev Time 0.00
Received By rmcdouga Date 2011-06-02 Time 11:22 Sent To  
Notes
2011-06-02 11:23:42IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.

Review Stop L LANDSCAPING
Rev No 3 Status P Date 2011-08-17 Cont ID  
Sent By astelly Date 2011-08-17 Time 14:38 Rev Time 0.00
Received By astelly Date 2011-08-17 Time 14:38 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 2 Status F Date 2011-08-15 Cont ID  
Sent By astelly Date 2011-08-15 Time 11:13 Rev Time 0.00
Received By astelly Date 2011-08-15 Time 11:11 Sent To  
Notes
2011-08-15 11:13:21AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 COMMENTS OF 5/20/11 LANDSCAPE REVIEW STILL APPLY.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2011-05-20 Cont ID  
Sent By rkussner Date 2011-05-20 Time 14:39 Rev Time 0.00
Received By rkussner Date 2011-05-20 Time 14:39 Sent To  
Notes
2011-05-20 14:54:17***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. PLEASE APPLY FOR A SEPARATE LANDSCAPE PERMIT. SUBMIT
 TWO (2) COPIES OF A LANDSCAPE PLAN SHOWING COMPLIANCE
 WITH SECTIONS 94-442 AND 94-445 OF THE ZLDR AND A
 CERTIFIED COST ESTIMATE THAT INCLUDES THE TOTAL COST OF
 ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO
 UNIT COST.
  
 2. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE
 XERISCAPE DESIGN OPTIONS.
  
 3. PURSUANT TO SECTION 94-448 (D) (2), ALL OF THE ITEMS
 ENUMERATED IN THIS SECTION SHALL BE INCLUDED IN THE
 LANDSCAPE PLAN.
  
 4. PLEASE APPLY FOR AN IRRIGATION PERMIT AND SUBMIT TWO
 COPIES OF AN IRRIGATION PLAN THAT PROVIDES 120%
 COVERAGE TO ALL LANDSCAPED AREAS, INCLUDING THE
 RIGHT-OF-WAY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2011-08-17 Cont ID  
Sent By rmcdouga Date 2011-08-17 Time 07:51 Rev Time 0.00
Received By rmcdouga Date 2011-08-17 Time 07:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2011-08-02 Cont ID  
Sent By rmcdouga Date 2011-08-02 Time 15:11 Rev Time 0.00
Received By rmcdouga Date 2011-08-02 Time 15:11 Sent To  
Notes
2011-08-02 15:30:532007 FBC W/2009 REVISIONS
  
 DENIED BY MECHANICAL
  
 1) SPECIFY THE SIZE OF THE DUCT SUPPLYING BEDROOM #2.
  
 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE HVAC PLANS.
  
 3) THE 10" TRANSFER DUCTS FOR BEDROOMS # 1 & 2 IS TOO
 SMALL FOR A 9" SUPPLY DUCT. A 12" TRANSFER DUCT WITH A
 1" DOOR UNDERCUT IS REQUIRED PER FBCR M1602.4.
  
 4) SPECIFY THE SIZE OF THE RETURN GRILL IN BEDROOM #4.
  
 5) PLEASE CLARIFY THE 14 X 14 GRILL AND 811 CFM SHOWN
 AT BATH #2.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2011-06-24 Cont ID  
Sent By rmcdouga Date 2011-06-24 Time 10:18 Rev Time 0.00
Received By rmcdouga Date 2011-08-17 Time 07:11 Sent To  
Notes
2011-06-24 10:21:132007 FBC W/2009 REVISIONS
  
 DENIED BY MECHANICAL
  
 1) SUBMIT TWO SETS OF MECHANICAL PLANS FROM A FLORIDA
 LICENSED ARCHITECT, ENGINEER OR MECHANICAL CONTRACTOR
 AS REQUIRED BY FS 481, 471 OR EXEMPTION 471.003(H).
  
 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS THAT HAVE
 BEEN SIGNED AND DATED BY THE PREPARER AND THE
 OWNER/AGENT AS REQUIRED BY FBC SECTION 13-600.
  
 3) SUBMIT TWO SETS OF HEATING AND COOLING EQUIPMENT
 SIZING CALCULATIONS AS REQUIRED BY FBC 13-607.AB.1.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-06-01 Cont ID  
Sent By rmcdouga Date 2011-06-01 Time 07:46 Rev Time 0.00
Received By rmcdouga Date 2011-06-01 Time 07:46 Sent To  
Notes
2011-06-01 08:13:522007 FBC W/2009 REVISIONS
  
 DENIED BY MECHANICAL
  
 1) ALTHOUGH THE COVER SHEET OF THE PLANS SPECIFIES
 MECHANICAL DRAWINGS ARE ON SHEET 21 OF THE PLANS, THERE
 WERE NONE. SUBMIT TWO SETS OF MECHANICAL PLANS FROM A
 FLORIDA LICENSED ARCHITECT, ENGINEER OR MECHANICAL
 CONTRACTOR AS REQUIRED BY FS 481, 471 OR EXEMPTION
 471.003(H).
  
 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS THAT HAVE
 BEEN SIGNED AND DATED BY THE PREPARER AND THE
 OWNER/AGENT AS REQUIRED BY FBC SECTION 13-600.
  
 3) SUBMIT TWO SETS OF HEATING AND COOLING EQUIPMENT
 SIZING CALCULATIONS AS REQUIRED BY FBC 13-607.AB.1.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2011-08-02 Cont ID  
Sent By rmcdouga Date 2011-08-02 Time 12:10 Rev Time 0.00
Received By rmcdouga Date 2011-08-02 Time 12:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2011-06-24 Cont ID  
Sent By rmcdouga Date 2011-06-24 Time 10:23 Rev Time 0.00
Received By rmcdouga Date 2011-06-24 Time 10:23 Sent To  
Notes
2011-06-24 10:24:482007 FBC W/2009 REVISIONS
  
 DENIED BY PLUMBING
  
 NOTE: THE NEW PLANS ARE FOR A COMPLETELY DIFFERENT
 DWELLING.
  
 1) THE NAME OF THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE PLUMBING SYSTEM IS REQUIRED ON THE DRAWINGS. IF
 DESIGNED BY A FLORIDA LICENSED ARCHITECT OR ENGINEER
 THE DRAWINGS ARE REQUIRED TO BE SIGNED AND SEALED AS
 REQUIRED BY FLORIDA STATUTES FS CHAPTERS 481 AND 471.
 IF DESIGNED BY A FLORIDA LICENSED PLUMBING CONTRACTOR
 UNDER EXEMPTION FS 471.003 (H), THE NAME LICENSE NUMBER
 AND SIGNATURE OF THE CONTRACTOR IS REQUIRED ON THE
 DRAWINGS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-06-01 Cont ID  
Sent By rmcdouga Date 2011-06-01 Time 07:26 Rev Time 0.00
Received By rmcdouga Date 2011-06-01 Time 07:06 Sent To  
Notes
2011-06-01 07:45:252007 FBC W/2009 REVISIONS
  
 DENIED BY PLUMBING
  
 1) THE NAME OF THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE PLUMBING SYSTEM IS REQUIRED ON THE DRAWINGS. IF
 DESIGNED BY A FLORIDA LICENSED ARCHITECT OR ENGINEER
 THE DRAWINGS ARE REQUIRED TO BE SIGNED AND SEALED AS
 REQUIRED BY FLORIDA STATUTES FS CHAPTERS 481 AND 471.
 IF DESIGNED BY A FLORIDA LICENSED PLUMBING CONTRACTOR
 UNDER EXEMPTION FS 471.003 (H), THE NAME LICENSE NUMBER
 AND SIGNATURE OF THE CONTRACTOR IS REQUIRED ON THE
 DRAWINGS.
  
 2) THE PLANS SPECIFY A SELF VENTING KITCHEN SINK.
 PLEASE CLARIFY. DID YOU INTEND FOR THE KITCHEN SINK TO
 BE VENTED WITH AN AIR ADMITTANCE VALVE (AAV) AS ALLOWED
 BY FBCR SECTION P3114?
  
 3) PROVIDE A ROOF DRAINAGE PLAN. INDICATE THE LOCATIONS
 AND SIZES OF ALL ROOF DRAINS, SCUPPERS AND SECONDARY
 DRAINS. PROVIDE SCUPPER SIZING CALCULATIONS. FBC
 R903.4, FBC P 1105, 1106 AND 1107.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 4 Status P Date 2011-08-17 Cont ID  
Sent By astelly Date 2011-08-17 Time 14:37 Rev Time 0.00
Received By astelly Date 2011-08-17 Time 14:37 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2011-08-15 Cont ID  
Sent By astelly Date 2011-08-15 Time 11:14 Rev Time 0.00
Received By astelly Date 2011-08-15 Time 11:13 Sent To  
Notes
2011-08-15 12:07:19AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 A LANDSCAPE PLAN IS REQUIRED FOR NEW CONSTRUCTION.
 PLEASE APPLY FOR A SEPARATE LANDSAPE PERMIT.
  
 A TREE REMOVAL PERMIT IS REQUIRED FOR THE REMOVAL OF
 ANY TREES ON THE PROPERTY.
  
 THIS PROJECT IS BEING REVIEWED A SINGLE FAMILY
 RESIDENCE. PLEASE BE ADVISED THAT CONGREGATE LIVING
 WILL NOT BE ALLOWED. THEREFORE, NO MORE THAN TWO (2)
 UNRELATED PEOPLE WILL BE ALLOWED TO RESIDE ON THE
 PROPERTY. ALL OTHERS MUST BE RELATED BY MARRIAGE OR
 BLOOD.

Review Stop Z ZONING
Rev No 2 Status F Date 2011-07-09 Cont ID  
Sent By astelly Date 2011-07-09 Time 15:05 Rev Time 0.00
Received By astelly Date 2011-07-09 Time 15:05 Sent To  
Notes
2011-07-09 15:06:25AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 REPEAT COMMENTS:
  
 A SURVEY, AND A SITE PLAN SHOWING ALL SETBACKS IS
 REQUIRED FOR REVIEW. A LANDSCAPE PLAN UNDER A SEPARATE
 LANDSCAPE PERMIT IS ALSO REQUIRED. A TREE REMOVAL
 PERMIT WILL BE REQUIRED FOR ANY TREES THAT MUST BE
 REMOVED FROM THE SITE.

Review Stop Z ZONING
Rev No 1 Status F Date 2011-05-26 Cont ID  
Sent By astelly Date 2011-05-26 Time 19:43 Rev Time 0.00
Received By astelly Date 2011-05-26 Time 19:43 Sent To  
Notes
2011-05-26 19:45:48AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 A SURVEY, AND A SITE PLAN SHOWING ALL SETBACKS IS
 REQUIRED FOR REVIEW. A LANDSCAPE PLAN UNDER A SEPARATE
 LANDSCAPE PERMIT IS ALSO REQUIRED. A TREE REMOVAL
 PERMIT WILL BE REQUIRED FOR ANY TREES THAT MUST BE
 REMOVED FROM THE SITE.