| Plan Review Stops For Permit 11050388 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2011-08-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-08-22 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-22 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2011-08-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-08-17 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-17 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2011-08-17 07:32:47 | 2007 FBC W/2009 REVISIONS | | | | | | 1) SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE | | | STRUCTURE AS REQUIRED BY FBCR N1100.3. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2011-08-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-08-03 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-03 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2011-08-03 09:39:28 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) PROVIDE TWO COPIES OF A SURFACE WATER DRAINAGE PLAN | | | SHOWING COMPLIANCE WITH FBC R401.3. THE SURVEY DOES NOT | | | ADDRESS SURFACE WATER DRAINAGE OR SHOW COMPLIANCE WITH | | | FBC R401.3. | | | | | | 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE | | | STRUCTURE AS REQUIRED BY FBCR N1100.3. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-24 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-24 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2011-06-24 11:28:26 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO COPIES OF A SURVEY/SITE PLAN SHOWING THE | | | LOCATION OF THE PROPOSED STRUCTURE ON THE LOT AND THE | | | DISTANCES TO THE PROPERTY LINES. FBC R302.1 | | | | | | 2) PROVIDE TWO COPIES OF A SURFACE WATER DRAINAGE PLAN | | | SHOWING COMPLIANCE WITH FBC R401.3. | | | | | | 3) SHOW COMPLIANCE WITH FBC R 403.1.4 WHICH REQUIRES | | | ALL EXTERIOR FOOTINGS TO BE AT LEAST 12 INCHES BELOW | | | GRADE. | | | | | | 4) SUBMIT TWO SETS OF ENERGY CALCULATIONS FORMS FOR THE | | | STRUCTURE AS REQUIRED BY FBCR N1100.3. | | | | | | 5) PROVIDE WINDOW AND DOOR BUCK FASTENING DETAILS | | | COMPLYING WITH FBC R613.6.1.1. | | | | | | 6) SHOW COMPLIANCE WITH FBC R3I3 FOR REQUIRED SMOKE | | | ALARMS. | | | | | | 7) THE DESIGNER OF RECORD FOR THE STRUCTURE IS REQUIRED | | | TO REVIEW AND APPROVE THE PRODUCT APPROVALS IN WRITING. | | | CITY AMENDMENTS 106.3.3 | | | | | | 8) THE STRUCTURE IS LOCATED WITHIN 1500 FEET OF THE | | | INTRACOASTAL WATERWAY WHICH MAKES THE EXPOSURE CATEGORY | | | C. PLEASE CORRECT SHEET 3 AND REVISE THE REQUIRED | | | WINDOW AND DOOR DESIGN LOADS ON SHEET 2. | | | | | | 9) FBC R803.2.3.1 REQUIRES ROOF SHEATHING FASTENER | | | SPACING TO BE 6" OC IN THE FIELD AS WELL AS THE EDGES. | | | PLEASE REVISE NOTES ON SHEET 4. | | | | | | 10) THE VALUE OF THE PROJECT HAS BEEN INCREASED FROM | | | $125,000.00 TO $129,922.00 BASED ON THE CURRENT ICC | | | VALUATION DATA TABLES. CITY AMENDMENTS 108.3 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-06-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-02 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-03 |
Time |
07:20 |
Sent To |
|
|
| Notes |
| 2011-06-02 15:05:58 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO COPIES OF A SURVEY/SITE PLAN SHOWING THE | | | LOCATION OF THE PROPOSED STRUCTURE ON THE LOT AND THE | | | DISTANCES TO THE PROPERTY LINES. FBC R302.1 | | | | | | 2) PROVIDE TWO COPIES OF A SURFACE WATER DRAINAGE PLAN | | | SHOWING COMPLIANCE WITH FBC R401.3. | | | | | | 3) SHOW COMPLIANCE WITH FBC R 602.1.2 (1) - (4) FOR | | | FIRE BLOCKING. SEVERAL OF THE CROSS SECTION DRAWINGS ON | | | THE PLANS HAVE AREAS THAT REQUIRE FIRE BLOCKING | | | INCLUDING THE STAIRS. | | | | | | 4) SHOW COMPLIANCE WITH FBC R703.6.3 WHICH REQUIRES A | | | BOND BREAK BETWEEN THE REQUIRED WATER-RESISTIVE BARRIER | | | (R703.2) AND THE STUCCO. | | | | | | 5) SHOW COMPLIANCE WITH FBC R320.7 WHICH REQUIRES | | | DOWNSPOUTS TO DISCHARGE AT LEAST 1 FOOT AWAY FROM THE | | | STRUCTURE. | | | | | | 6) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE | | | EXTERIOR DOORS, WINDOWS, ROOFING MATERIAL, STORM | | | PANELS, AND PANEL WALLS AS REQUIRED BY DCA RULE 9N-3. | | | | | | 7) SUBMIT SHOP DRAWINGS FOR THE PANEL WALLS THAT HAVE | | | BEEN REVIEWED AND ACCEPTED BY THE DESIGNER OF RECORD OF | | | THE STRUCTURE. | | | | | | 8) SHOW COMPLIANCE WITH FBC R312 FOR THE STAIR AND | | | LANDING GUARD HEIGHTS AND OPENING LIMITATIONS. | | | | | | 9) SHOW COMPLIANCE WITH FBC R806 FOR ROOF VENTILATION. | | | | | | 10) PLEASE PROVIDE A RESPONSE LETTER INDICATING HOW | | | EACH OF THE REVIEW COMMENTS HAVE BEEN ADDRESSED. | | | | | | 11) THE VALUE OF THE PROJECT HAS BEEN INCREASED FROM | | | $125,000.00 TO $274,638.00 BASED ON THE CURRENT ICC | | | VALUATION DATA TABLES. CITY AMENDMENTS 108.3 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2011-07-27 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-07-27 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-07-27 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2011-06-20 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-06-20 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-06-20 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2011-06-20 14:00:21 | | | | PLEASE REVISE THE PLAN TO INCLUDE THE FOLLOWING: | | | ADDITIONAL RECEPTACLES REQUIRED IN THE BEDROOMS AND | | | HALLWAY. ADD RECEPTACLES SO THAT NO WALL SPACE IS MORE | | | THAN 6 FEET FROM A RECEPTACLE AND ALL WALL SPACES MORE | | | THAN 2 FEET IN WIDTH HAVE A RECEPTACLE. NEC 210.52 | | | PROVIDE INTERCONNECTED SMOKE DETECTORS WITH BATTERY | | | BACKUP INSIDE AND OUTSIDE ALL SLEEPING AREAS. FBC | | | R313.2 | | | PROVIDE AN INTERSYSTEM BONDING STRIP AT THE SERVICE | | | GROUND. NEC 250.94 | | | RECEPTACLES MUST BE ARC FAULT CIRCUIT PROTECTED AND | | | TAMPER RESISTANT. NEC 406.11, NEC 210-12 (B) | | | PROVIDE A 20 AMP BRANCH CIRCUIT FOR THE BATHROOMS. NEC | | | 210.11 (C)(3) | | | VERIFY THE AVAILABLE FAULT CURRENT AT THE ELECTRIC | | | SERVICE IS LESS THAN 10,000 AIC. NEC 110.9 | | | PROVIDE ACCESS AND SAFETY CLEARANCES IN FRONT AND SIDE | | | TO SIDE AT THE ELECTRICAL PANEL BOARD. NEC 110.26 | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-06-01 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-05-25 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-05-25 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2011-06-01 10:22:34 | ADDITIONAL RECEPTACLES REQUIRED IN THE ENTRANCE HALL | | | WAY, EAST HALL AND ON WEST WALL. ADD RECEPTACLES SO | | | THAT NO WALL SPACE IS MORE THAN 6 FEET FROM A | | | RECEPTACLE AND ALL WALL SPACES MORE THAN 2 FEET IN | | | WIDTH HAVE A RECEPTACLE. ADDITIONAL RECEPTACLES | | | REQUIRED ON BOTH FLOORS. NEC 210.52 | | | KITCHEN RECEPTACLES SERVING THE COUNTER TOP SURFACES | | | MUST BE GFCI PROTECTED. NEC 210.8 | | | PROVIDE INTERCONNECTED SMOKE DETECTORS WITH BATTERY | | | BACKUP INSIDE AND OUTSIDE ALL SLEEPING AREAS. FBC | | | R313.2 | | | PROVIDE AN INTERSYSTEM BONDING STRIP AT THE SERVICE | | | GROUND. NEC 250.94 | | | RECEPTACLES MUST BE ARC FAULT CIRCUIT PROTECTED AND | | | TAMPER RESISTANT. NEC 406.11, NEC 210-12 (B) | | | PROVIDE A BRANCH CIRCUIT FOR THE BATHROOMS. NEC 210.11 | | | (C)(3) | | | VERIFY THE AVAILABLE FAULT CURRENT AT THE ELECTRIC | | | SERVICE IS LESS THAN 10,000 AIC. NEC 110.9 | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2011-08-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-08-17 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-16 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2011-08-16 15:29:46 | TO ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-08-22 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-08-15 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-07-22 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2011-07-22 17:22:30 | ************EXPEDITED************ | | | R--13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-07-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-07-09 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-06-20 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2011-06-20 08:08:07 | ***** EXPEDITED 2ND RUN ***** | | | R13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2011-06-02 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2011-05-13 |
Time |
10:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2011-08-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-08-23 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-23 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2011-08-23 14:38:02 | EXISTING USE CREDIT. NO FEES DUE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2011-06-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-02 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-02 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2011-06-02 11:23:42 | IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
2011-08-17 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-08-17 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-08-17 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
2011-08-15 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-08-15 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-08-15 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2011-08-15 11:13:21 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | COMMENTS OF 5/20/11 LANDSCAPE REVIEW STILL APPLY. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2011-05-20 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2011-05-20 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2011-05-20 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2011-05-20 14:54:17 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT. | | | | | | 1. PLEASE APPLY FOR A SEPARATE LANDSCAPE PERMIT. SUBMIT | | | TWO (2) COPIES OF A LANDSCAPE PLAN SHOWING COMPLIANCE | | | WITH SECTIONS 94-442 AND 94-445 OF THE ZLDR AND A | | | CERTIFIED COST ESTIMATE THAT INCLUDES THE TOTAL COST OF | | | ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO | | | UNIT COST. | | | | | | 2. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE | | | EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE | | | XERISCAPE DESIGN OPTIONS. | | | | | | 3. PURSUANT TO SECTION 94-448 (D) (2), ALL OF THE ITEMS | | | ENUMERATED IN THIS SECTION SHALL BE INCLUDED IN THE | | | LANDSCAPE PLAN. | | | | | | 4. PLEASE APPLY FOR AN IRRIGATION PERMIT AND SUBMIT TWO | | | COPIES OF AN IRRIGATION PLAN THAT PROVIDES 120% | | | COVERAGE TO ALL LANDSCAPED AREAS, INCLUDING THE | | | RIGHT-OF-WAY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2011-08-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-08-17 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-17 |
Time |
07:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2011-08-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-08-02 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-02 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2011-08-02 15:30:53 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY MECHANICAL | | | | | | 1) SPECIFY THE SIZE OF THE DUCT SUPPLYING BEDROOM #2. | | | | | | 2) PROVIDE AN EQUIPMENT SCHEDULE ON THE HVAC PLANS. | | | | | | 3) THE 10" TRANSFER DUCTS FOR BEDROOMS # 1 & 2 IS TOO | | | SMALL FOR A 9" SUPPLY DUCT. A 12" TRANSFER DUCT WITH A | | | 1" DOOR UNDERCUT IS REQUIRED PER FBCR M1602.4. | | | | | | 4) SPECIFY THE SIZE OF THE RETURN GRILL IN BEDROOM #4. | | | | | | 5) PLEASE CLARIFY THE 14 X 14 GRILL AND 811 CFM SHOWN | | | AT BATH #2. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2011-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-24 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-17 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2011-06-24 10:21:13 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY MECHANICAL | | | | | | 1) SUBMIT TWO SETS OF MECHANICAL PLANS FROM A FLORIDA | | | LICENSED ARCHITECT, ENGINEER OR MECHANICAL CONTRACTOR | | | AS REQUIRED BY FS 481, 471 OR EXEMPTION 471.003(H). | | | | | | 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS THAT HAVE | | | BEEN SIGNED AND DATED BY THE PREPARER AND THE | | | OWNER/AGENT AS REQUIRED BY FBC SECTION 13-600. | | | | | | 3) SUBMIT TWO SETS OF HEATING AND COOLING EQUIPMENT | | | SIZING CALCULATIONS AS REQUIRED BY FBC 13-607.AB.1. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-06-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-01 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-01 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2011-06-01 08:13:52 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY MECHANICAL | | | | | | 1) ALTHOUGH THE COVER SHEET OF THE PLANS SPECIFIES | | | MECHANICAL DRAWINGS ARE ON SHEET 21 OF THE PLANS, THERE | | | WERE NONE. SUBMIT TWO SETS OF MECHANICAL PLANS FROM A | | | FLORIDA LICENSED ARCHITECT, ENGINEER OR MECHANICAL | | | CONTRACTOR AS REQUIRED BY FS 481, 471 OR EXEMPTION | | | 471.003(H). | | | | | | 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS THAT HAVE | | | BEEN SIGNED AND DATED BY THE PREPARER AND THE | | | OWNER/AGENT AS REQUIRED BY FBC SECTION 13-600. | | | | | | 3) SUBMIT TWO SETS OF HEATING AND COOLING EQUIPMENT | | | SIZING CALCULATIONS AS REQUIRED BY FBC 13-607.AB.1. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2011-08-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-08-02 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-08-02 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2011-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-24 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-24 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2011-06-24 10:24:48 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY PLUMBING | | | | | | NOTE: THE NEW PLANS ARE FOR A COMPLETELY DIFFERENT | | | DWELLING. | | | | | | 1) THE NAME OF THE PERSON RESPONSIBLE FOR THE DESIGN OF | | | THE PLUMBING SYSTEM IS REQUIRED ON THE DRAWINGS. IF | | | DESIGNED BY A FLORIDA LICENSED ARCHITECT OR ENGINEER | | | THE DRAWINGS ARE REQUIRED TO BE SIGNED AND SEALED AS | | | REQUIRED BY FLORIDA STATUTES FS CHAPTERS 481 AND 471. | | | IF DESIGNED BY A FLORIDA LICENSED PLUMBING CONTRACTOR | | | UNDER EXEMPTION FS 471.003 (H), THE NAME LICENSE NUMBER | | | AND SIGNATURE OF THE CONTRACTOR IS REQUIRED ON THE | | | DRAWINGS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-06-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-01 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-01 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2011-06-01 07:45:25 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY PLUMBING | | | | | | 1) THE NAME OF THE PERSON RESPONSIBLE FOR THE DESIGN OF | | | THE PLUMBING SYSTEM IS REQUIRED ON THE DRAWINGS. IF | | | DESIGNED BY A FLORIDA LICENSED ARCHITECT OR ENGINEER | | | THE DRAWINGS ARE REQUIRED TO BE SIGNED AND SEALED AS | | | REQUIRED BY FLORIDA STATUTES FS CHAPTERS 481 AND 471. | | | IF DESIGNED BY A FLORIDA LICENSED PLUMBING CONTRACTOR | | | UNDER EXEMPTION FS 471.003 (H), THE NAME LICENSE NUMBER | | | AND SIGNATURE OF THE CONTRACTOR IS REQUIRED ON THE | | | DRAWINGS. | | | | | | 2) THE PLANS SPECIFY A SELF VENTING KITCHEN SINK. | | | PLEASE CLARIFY. DID YOU INTEND FOR THE KITCHEN SINK TO | | | BE VENTED WITH AN AIR ADMITTANCE VALVE (AAV) AS ALLOWED | | | BY FBCR SECTION P3114? | | | | | | 3) PROVIDE A ROOF DRAINAGE PLAN. INDICATE THE LOCATIONS | | | AND SIZES OF ALL ROOF DRAINS, SCUPPERS AND SECONDARY | | | DRAINS. PROVIDE SCUPPER SIZING CALCULATIONS. FBC | | | R903.4, FBC P 1105, 1106 AND 1107. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2011-08-17 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-08-17 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-08-17 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2011-08-15 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-08-15 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-08-15 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2011-08-15 12:07:19 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | A LANDSCAPE PLAN IS REQUIRED FOR NEW CONSTRUCTION. | | | PLEASE APPLY FOR A SEPARATE LANDSAPE PERMIT. | | | | | | A TREE REMOVAL PERMIT IS REQUIRED FOR THE REMOVAL OF | | | ANY TREES ON THE PROPERTY. | | | | | | THIS PROJECT IS BEING REVIEWED A SINGLE FAMILY | | | RESIDENCE. PLEASE BE ADVISED THAT CONGREGATE LIVING | | | WILL NOT BE ALLOWED. THEREFORE, NO MORE THAN TWO (2) | | | UNRELATED PEOPLE WILL BE ALLOWED TO RESIDE ON THE | | | PROPERTY. ALL OTHERS MUST BE RELATED BY MARRIAGE OR | | | BLOOD. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2011-07-09 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-07-09 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-07-09 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2011-07-09 15:06:25 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | REPEAT COMMENTS: | | | | | | A SURVEY, AND A SITE PLAN SHOWING ALL SETBACKS IS | | | REQUIRED FOR REVIEW. A LANDSCAPE PLAN UNDER A SEPARATE | | | LANDSCAPE PERMIT IS ALSO REQUIRED. A TREE REMOVAL | | | PERMIT WILL BE REQUIRED FOR ANY TREES THAT MUST BE | | | REMOVED FROM THE SITE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-05-26 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-05-26 |
Time |
19:43 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-05-26 |
Time |
19:43 |
Sent To |
|
|
| Notes |
| 2011-05-26 19:45:48 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | A SURVEY, AND A SITE PLAN SHOWING ALL SETBACKS IS | | | REQUIRED FOR REVIEW. A LANDSCAPE PLAN UNDER A SEPARATE | | | LANDSCAPE PERMIT IS ALSO REQUIRED. A TREE REMOVAL | | | PERMIT WILL BE REQUIRED FOR ANY TREES THAT MUST BE | | | REMOVED FROM THE SITE. |
|
|