| Plan Review Stops For Permit 11050309 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2011-11-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-11-28 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-11-28 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2011-11-28 10:39:12 | CONTRACTOR'S SET OF PLANS WAS REDLINED TO MATCHED FILE | | | SET. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2011-10-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-10-24 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-10-24 |
Time |
07:58 |
Sent To |
E |
|
| Notes |
| 2011-10-24 09:28:34 | 2007 FBC W/2009 REVISIONS | | | | | | 1) THE WIND LOAD ANALYSIS FOR THE MWFRS AND COMPONENT | | | AND CLADDING PRESSURES FROM THE ENGINEER, THE SHAFFER | | | GROUP INC. IS NOT SIGNED AND SEALED AS REQUIRED BY FS | | | 471 AND FAC 61G15.23.002. SUBMIT TWO SETS OF SIGNED AND | | | SEALED WIND CALCULATIONS. | | | | | | 2) THE AWNING RECONSTRUCTION DETAIL SK-1 FROM THE | | | ENGINEER, THE SHAFFER GROUP INC. IS NOT SIGNED AND | | | SEALED AS REQUIRED BY FS 471 AND FAC 61G15.23.002. | | | SUBMIT TWO SETS OF SIGNED AND SEALED DRAWINGS. | | | | | | 3) ONE SET OF PLANS HAS HAND WRITTEN CHANGES MADE BY | | | THE ARCHITECT, LEE KVARNBERG. THE OTHER SET WILL NEED | | | TO BE MARKED UP TO MATCH. CITY AMENDMENTS 106.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-06-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-03 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-01 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2011-06-03 12:11:11 | 2007 FBC W/2009 REVISIONS | | | | | | DENIED BY BUILDING | | | | | | 1) THE OWNER BUILDER'S SIGNATURE ON THE APPLICATION AND | | | ON THE OWNER BUILDER DISCLOSURE FORM HAS TO BE | | | NOTARIZED. | | | | | | 2) SPECIFY THE WIND DESIGN DATA ON THE PLANS FBC | | | R301.1. THE WINDSPEED IS 140 MPH AND THE EXPOSURE | | | CATEGORY IS 'B' FOR THIS STRUCTURE. | | | | | | 3) SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR THE | | | WINDOWS AND DOORS ON THE PLANS. FBC R301.2.1 | | | | | | 4) PROVIDE STRUCTURAL DETAILS FOR THE NEW OPENINGS IN | | | THE EXTERIOR WALL. FBC R601.2 | | | | | | 5) SPECIFY THE 2 X 4 WOOD RAFTER TO THE RIDGE BOARD AND | | | WOOD BEAM ATTACHMENTS AT THE COVERED PORCH AND WINDOW | | | AWNINGS ON THE PLANS. FBC R301.1 | | | | | | 6) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE CLAY | | | ROOF TILES. SPECIFY THE ATTACHMENT METHOD FROM THE | | | PRODUCT APPROVAL THAT WILL BE USED TO INSTALL THE TILE. | | | DCA RULE 9N-3. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2011-11-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-11-28 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-11-28 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2011-11-28 10:38:20 | CONTRACTOR'S SET OF PLANS WAS REDLINED TO MATCH FILE | | | SET. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-10-26 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-10-26 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2011-10-26 09:56:43 | ONLY ONE SET OF PLANS REVISED. TWO SETS OF REVISIONS | | | FOR THE ELECTRICAL PLAN ARE REQUIRED. | | | ELECTRICAL FEEDER WITH OVERCURRENT PROTECTION TO NEW | | | PANEL IN GARAGE NOT SPECIFIED. MIN. #3 FEEDERS WITH # 8 | | | GROUND REQUIRED FOR A 100 AMPERE SUB PANEL. SMOKE | | | DETECTORS REQUIRED IN ALL BEDROOMS. | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-05-25 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-05-25 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-05-25 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2011-05-25 09:56:06 | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE DETECTORS WITH BATTERY | | | BACK UP. HOMES WHICH FEATURE GAS APPLIANCES, AN | | | ATTACHED GARAGE OR A FIRE PLACE REQUIRE A CARBON | | | MONOXIDE DETECTOR WITHIN TEN FEET OF EACH ROOM USED FOR | | | SLEEPING. FBC R313 | | | PROVIDE AN INTERSYSTEM BONDING STRIP AT THE SERVICE | | | GROUND. NEC 250.94 | | | NEW RECEPTACLES MUST BE ARC FAULT CIRCUIT PROTECTED. | | | NEC 210-12 (B) | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | | ADD RECEPTACLES SO THAT NO WALL SPACE IS MORE THAN 6 | | | FEET FROM A RECEPTACLE AND ALL WALL SPACES 2 FEET OR | | | MORE IN WIDTH HAVE A RECEPTACLE. NEDC 210.52 | | | THE PLAN SHOWS MULTIPLE ELECTRIC CIRCUITS FEEDING THE | | | GARAGE. A SEPARATE DISCONNECT AND PANELBOARD IS | | | REQUIRED. NEC 225-30 | | | | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-05-12 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2011-05-12 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2011-05-12 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-11-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-11-28 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-11-21 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-10-26 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-10-26 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-10-14 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2011-10-14 10:30:43 | INCOMING SENT TO R MCDOUGALS DESK. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-06-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-03 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-05-12 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
N |
Date |
2011-05-19 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2011-05-19 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2011-05-19 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2011-05-19 16:07:13 | ***LANDSCAPE NOT REQUIRED*** | | | | | | PLEASE REFER TO PERMIT NUMBER 11050543 FOR LANDSCAPE | | | PERMIT AND PLANS.--RAK | | | PLEASE NOTE THAT THE LANDSCAPE PLANS MUST BE SUBMITTED, | | | APPROVED AND SUCCESSFULLY INSPECTED PRIOR TO C/O. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2011-05-17 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2011-05-17 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2011-05-17 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2011-06-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-01 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-01 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2011-06-01 11:59:22 | NO MECHANICAL PLANS WERE SUBMITTED AND NO MECHANICAL | | | PERMIT WAS APPLIED FOR. A SEPARATE PERMIT, PLANS AND | | | EQUIPMENT SIZING CALCULATIONS WILL BE REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2011-06-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2011-06-01 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2011-06-01 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2011-05-20 |
|
|
Cont ID |
|
| Sent By |
jpapa |
Date |
2011-05-20 |
Time |
10:35 |
Rev Time |
0.25 |
| Received By |
jpapa |
Date |
2011-05-20 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2011-05-20 10:42:40 | APPLICANT HAS SUBMITTED A LANDSCAPE PLAN TO COMPLY WITH | | | PREVIOUS ZONING COMMENTS (SEE PERMIT #11050543). | | | | | | JILLIAN PAPA | | | HISTORIC PRESERVATION PLANNER | | | 561-822-1454 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-05-13 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2011-05-12 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2011-05-12 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2011-05-17 15:45:46 | THE VALUE OF THE CONSTRUCTION ($34,000) EXCEEDS 50% OF | | | THE STRUCTURE'S VALUE ($44,498) ACCORDING TO THE P.B.C. | | | PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT TO | | | SECTION 94-441(C)(2) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | | SITE INTO CONFORMITY. |
|
|