Plan Review Details - Permit 11040698
| Plan Review Stops For Permit 11040698 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-05-23 |
|
|
Cont ID |
|
| Sent By |
ddaniels |
Date |
2011-05-23 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
ddaniels |
Date |
2011-05-23 |
Time |
13:14 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-04-28 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-04-28 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-04-28 |
Time |
11:35 |
Sent To |
M |
|
| Notes |
| 2011-04-28 13:27:44 | 2465 MERCER AVENUE, SUITE #101 | | | PERMIT #11040698 | | | MASTER #11030091 | | | | | | JOB VALUATION OF $2,000 APPEARS LOW FOR SCOPE OF WORK. | | | JOB VALUE SHALL INCLUDE DESIGN, LABOR AND MATERIALS. | | | SUBMIT COPY OF OFFICIAL CONTRACT. | | | | | | PROVIDE AN ADDITIONAL BRANCHLINE OR SUBMIT HYDRAULIC | | | CALCULATIONS SUPPORTING THE DESIGN OF NINE SPRINKLERS | | | ON 1.5 INCH PIPING AS SHOWN IN THE TRAINING ROOM. | | | | | | PROVIDE SPRINKLER COVERAGE IN HALLWAY JUST WEST OF | | | OFFICE #1. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-05-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-05-25 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2011-05-18 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2011-05-18 07:28:27 | SENT TO FIRE BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-05-05 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-05-05 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-04-27 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2011-04-27 12:48:02 | SENT TO FIRE BOX. JW |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2011-05-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-05-25 |
Time |
13:53 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2011-05-25 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-05-05 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-05-05 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-05-05 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2011-05-05 07:21:55 | PLANS DENIED | | | VALUE APPEARS TO BE LOW PLEASE PROVIDE A COPY OF THE | | | CONTRACT WITH THE PLANS. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
|