Plan Review Details - Permit 11040676
Plan Review Stops For Permit 11040676
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-05-09 Cont ID  
Sent By jwitmer Date 2011-05-09 Time 13:22 Rev Time 1.22
Received By jwitmer Date 2011-05-09 Time 13:22 Sent To  
Notes
2011-05-09 13:23:29BUILDING PROVISO:
 SIGNAGE: 712.6 FIRE WALLS, FIRE BARRIERS, FIRE
 PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY
 OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE
 EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY
 HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE
 ANY DECORATIVE CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: "FIRE
 AND SMOKE BARRIER - PROTECT ALL OPENINGS."
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-04-29 Cont ID  
Sent By jwitmer Date 2011-04-29 Time 12:40 Rev Time 0.00
Received By jwitmer Date 2011-04-29 Time 11:54 Sent To  
Notes
2011-04-29 12:50:24BUILDING PLAN REVIEW
 PERMIT: 11040676
 ADD: 501 S FLAGLER DR
 CONT: SERRAES CONSTRUCTION
 TEL: (561)307-3384
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) OWNERS WERE CONTACTED, THE NEED FOR A KEY PLAN IS
 REQUIRED FOR ADDRESSING TO IDENTIFY THE NEW TENANT
 SPACE AND S ASSOCIATE THE SPACES BY NUMERICAL SUITE
 NUMBERS AND TO HAVE A PERMIT FOR EACH SUITE. WE WILL
 CREATE A SECOND PERMIT ONCE THE TWO TENANT SPACES CAN
 BE IDENTIFIED.
  
 2) THIS BUILDING IS A HIGH RISE BUILDING. THE PROJECT
 INFORMATION LOCATED ON THE COVER SHEET IDENTIFIES THIS
 BUILDING AS A TYPE III-B BUILDING.
 PLEASE REVIEW FBC-BUILDING TABLE 503 IT APPEARS THE
 MINIMUM BUILDING TYPE FOR A 12 STORY BUILDING WOULD BE
 A TYPE 1B FOR A BUSINESS OCCUPANCY.
  
 3) SINCE THIS IS NO LONGER A SINGLE TENANT FLOOR A
 COMMON AREA IS BEING CREATED, THE CONCERN IS THE SWING
 ON THE ELEVATOR LOBBY DOORS, ARE THESE DOORS FIRE RATED
 DOORS?
  
 4) PLEASE PROVIDE: 712.6 FIRE WALLS, FIRE BARRIERS,
 FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR
 ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS
 SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH
 SIGNS OR STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDENTIFICATION
 SHALL BE ABOVE ANY DECORATIVE CEILING AND IN CONCEALED
 SPACES. SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS:
 "FIRE AND SMOKE BARRIER - PROTECT ALL OPENINGS."
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-05-02 Cont ID  
Sent By rlecky Date 2011-05-02 Time 12:01 Rev Time 0.00
Received By rlecky Date 2011-05-02 Time 11:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-04-27 Cont ID  
Sent By wjolin Date 2011-04-27 Time 11:39 Rev Time 0.00
Received By wjolin Date 2011-04-27 Time 10:45 Sent To  
Notes
2011-04-27 11:39:22501 SOUTH FLAGLER DRIVE - SECOND FLOOR
 PERMIT #11040676
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SHEET A130 INCORRECTLY REFERENCES CHAPTER 36 MERCANTILE
 IN LIEU OF CHAPTER 38 BUSINESS IN NFPA 101.
  
 SHEET E-1 VERIFY ADEQUATE FIRE ALARM NOTIFICATION
 APPLIANCES EXIST WITH ADDITION OF TWO NEW DOORS LOCATED
 TO THE NORTH AND SOUTH OF THE RECEPTION DESK AREA.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-05-06 Cont ID  
Sent By lmartine Date 2011-05-06 Time 15:59 Rev Time 0.00
Received By lmartine Date 2011-04-27 Time 08:27 Sent To  
Notes
2011-04-27 08:27:46B16

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-05-06 Cont ID  
Sent By lmartine Date 2011-05-06 Time 15:59 Rev Time 0.00
Received By lmartine Date 2011-05-06 Time 15:59 Sent To  
Notes
2011-05-06 16:00:24SEE HAROLD MOSER'S SIGNATURE ON M-1.

Review Stop Z ZONING
Rev No 1 Status N Date 2011-05-05 Cont ID  
Sent By aaponte Date 2011-05-05 Time 11:51 Rev Time 0.10
Received By aaponte Date 2011-05-05 Time 11:51 Sent To  
Notes
***NONE***