| Plan Review Stops For Permit 11040647 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-06-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-06-02 |
Time |
10:24 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2011-06-02 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2011-06-02 11:33:11 | BUILDING PROVISO: | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 1) SHEET A-1 OCCUPANCY SEPERATION WALL (1 HOUR) BETWEEN | | | WAREHOUSE RESTROOM & BUSINESS/ MECANTILE SHOWROOM | | | MECHANICAL IS MISSING THE FIRE DAMPER PER : | | | 2007/09 FBC-B 716.1 GENERAL. THE PROVISIONS OF THIS | | | SECTION SHALL GOVERN THE PROTECTION OF DUCT | | | PENETRATIONS AND AIR TRANSFER OPENINGS IN ASSEMBLIES | | | REQUIRED TO BE PROTECTED. 716.3.1 FIRE PROTECTION | | | RATING. FIRE DAMPERS SHALL HAVE THE MINIMUM FIRE | | | PROTECTION RATING SPECIFIED IN TABLE 716.3.1 FOR THE | | | TYPE OF PENETRATION. | | | | | | 2ND REVIEW NO MECHANICAL SHEETS WERE SUBMITTED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-04-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-04-27 |
Time |
16:39 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2011-04-27 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2011-04-27 16:56:17 | BUILDING PLAN REVIEW | | | PERMIT: 11040647 | | | ADD: 1500 N FLORIDA MANGO RD | | | CONT: MALSKY HOMES | | | TEL: (561)329-9428 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET A-1 INDICATES NEW TENANT SEPERATION WALL | | | SECTIONSWALL DETAIL W1/A-1. MISSING DETAIL AND WALL | | | RATING ASSEMBLY, PLEASE REVIEW | | | 2007 FBC 708.1(3). | | | | | | 2) PLEASE PROVIDE WALL STENCILING FOR RATED WALL PER | | | 2007 FBC-B 712.6. | | | | | | 3) WAREHOUSE S-2 STORAGE RESTROOM WALL, A OCCUPANCY | | | SEPERATION WALL 1 HR RATED IS MISSING A FIRE DAMPER SEE | | | MECHANICAL PLANS. | | | | | | JAMES A. WITMER C.B.O. | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561)805-6715 | | | FAX:(561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2011-05-24 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-05-24 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-05-24 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2011-05-24 08:41:11 | RESTAMP |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-05-02 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-05-02 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-05-02 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2011-05-27 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-05-27 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-05-27 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-04-27 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-04-27 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-04-27 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2011-04-27 15:27:53 | 1500 NORTH FLORIDA MANGO ROAD, SUITE #1,2 8B & 9B | | | PERMIT #11040647 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | EACH NEW SMOKE OR FIRE-RATED WALL/PARTITION SHALL BE | | | PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING | | | FIRE SMOKE BARRIER PROTECT ALL OPENINGS. CHARACTERS | | | SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN | | | WIDTH. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 | | | FEET ON CENTER. REFERENCE SECTION 8.3.2.4 OF FLORIDA | | | FIRE PREVENTION CODE - NFPA 101 | | | | | | PENETRATIONS THROUGH A FIRE-RATED WALL ASSEMBLY SHALL | | | BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE. REFERENCE | | | SECTION 8.3.5.1 OF FLORIDA FIRE PREVENTION CODE - NFPA | | | 101 | | | | | | FOR ISSUANCE OF A GENERAL BUILDING PERMIT, ENGINEERING | | | CONSTRUCTION DOCUMENTS FOR THE FIRE SPRINKLER AND FIRE | | | ALARM WORK ARE REQUIRED. | | | | | | SEPARATE PLANS (SHOP DRAWINGS CONFORMING TO ENGINEERING | | | CONSTRUCTION DOCUMENTS) AND PERMITS ARE REQUIRED FOR | | | THE INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND FIRE ALARM SYSTEM. | | | | | | ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS | | | OF NFPA 241. | | | | | | FIRE RATED DOORS ARE REQUIRED TO BE AUTOMATICALLY | | | CLOSING. | | | | | | PROVIDE BUILDING ADDRESS VISIBLE FROM THE STREET. | | | NUMBERS SHALL BE AT LEAST SIX-INCHES IN HEIGHT AND | | | SHALL CONTRAST THE BACKGROUND. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | PROVIDE A FURNITURE/STORAGE/SHOWROOM LAYOUT PLAN | | | INDICATING WHAT, WHERE AND HOW OPERATIONS ARE BEING | | | PERFORMED. | | | | | | EXTINGUISHERS SHALL HAVE A MINIMUM RATING OF 2A:10BC | | | AND SHALL BE TAGGED BY A LICENSED FIRE EXTINGUISHER | | | COMPANY. | | | | | | PROVIDE FIRE DAMPER ON HVAC PLAN FOR DUCT PENETRATING | | | FIRE WALL SERVING SMALL RESTROON IN STORAGE OCCUPANCY. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-06-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-06-09 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-06-09 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2011-06-09 09:15:16 | **************EXPEDITED**************** | | | GAVE TO HAROLD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-06-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-06-03 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-05-19 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-05-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-05-11 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-04-27 |
Time |
08:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2011-06-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-06-09 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-06-09 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2011-06-09 15:17:05 | PASS PROVISO | | | REFER TO SECTION 601.4 BALANCED RETURN AIR 2007 FBC (M) | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | | E MAIL [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2011-06-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-06-03 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-06-03 |
Time |
06:58 |
Sent To |
|
|
| Notes |
| 2011-06-03 07:22:11 | NO MECHANICAL PLANS SUBMITTED. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | | E MAIL [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-05-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-05-11 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-05-11 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2011-05-11 11:20:49 | PLANS DENIED | | | 1) PROVIDE THE SIGNATURE AND LIC.NUMBER OF THE DESIGNER | | | ON THE PLANS. | | | 2) REFER TO SECTION 106.1.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. 2007 FBC | | | 1) PROVIDE CFM ON ALL SUPPLY GRAILS. ON THE PLANS. | | | 2) PROVIDE MAKE UP AIR ON THE PLANS. | | | 3) PROVIDE BATHROOM VENTILATION ON THE PLANS. | | | 4) PROVIDE HANGING DETAIL FOR AIRHANDLERS ON THE PLANS. | | | 5) PROVIDE TIE DOWN DETAIL THE CONDENSER TO SLAB.ON | | | PLANS. | | | 3) REFER TO SECTION 601.4 BALANCED RETURN AIR. 2007 | | | FBC(M) | | | 4) REFER TO SECTION 606.2.1 SUPPLY AIR. 2007 FBC (M) | | | 5) REFER TO SECTION 606.4.1 SUPERVISION. 2007 FBC (M) | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | 2011-05-11 10:42:27 | PLANS DENIED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-05-31 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-05-31 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-05-31 |
Time |
11:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2011-04-28 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-04-28 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-04-28 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2011-04-28 12:29:08 | REPLACING EXISTING FIXTURES ONLY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2011-05-10 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2011-05-10 |
Time |
08:33 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2011-05-10 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2011-05-10 08:34:18 | INTERIOR WORK ONLY, LESS THAN 50% OF BUILDING VALUE. |
|
|