| Plan Review Stops For Permit 11040608 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2011-04-26 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-04-26 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-04-26 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2011-04-26 12:37:27 | 1258 PALM BEACH LAKES BOULEVARD | | | PERMIT #11040608 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PROVIDE A PLACARD INDICATING THE USE OF THE TYPE K | | | EXTINGUISHER AS A SECONDARY MEANS TO THE AUTOMATIC FIRE | | | EXTINGUISHING SYSTEM. | | | | | | VERIFY EXHAUST SYSTEM AUTOMATICALLY OPERATES WHENEVER | | | COOKING EQUIPMENT IS TURNED ON. | | | | | | VERFIY DEEP FAT FRYERS ARE LOCATED AT LEAST 16 INCHES | | | AWAY FROM SURFACE FLAMES OF ADJACENT EQUIPMENT OR | | | PROVIDE AN 8 INCH TALL STEEL BAFFLE BETWEEN THE FRYER | | | AND THE STOVE. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-04-26 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-04-26 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-04-25 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2011-04-25 12:54:08 | SENT TO FIRE BOX. |
|
|
|