| Plan Review Stops For Permit 11040544 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2011-05-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-05-10 |
Time |
12:39 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2011-05-10 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2011-04-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-04-21 |
Time |
13:18 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2011-04-21 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2011-04-21 13:23:58 | | | | | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 11040544 | | | ADD: 1258 PALM BEACH LAKES | | | CONT: OCEAN BUILDERS | | | TEL: (772)341-6636 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. THERE HAS BEEN NO PLANS SUBMITTED ONLY A | | | SURVEY. HAND WRITTEN IS SCOPE OF WORK TO BE COMPLETED | | | UNDER THIS PERMIT INCLUDING REPLACEMENT OF EQUIPMENT. | | | WITHOUT THIS INFORMATION IT IS NOT POSSIBLE FOR THE | | | TRADES TO MAKE COMMENTS! 106.1.2 ADDITIONAL INFORMATION | | | REQUIED. PLEASE PROVIDE A FLOOR PLAN AND A LIFE SAFETY | | | PLAN. | | | | | | JAMES A. WITMER C.B.O. | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: (561)805-6715 | | | FAX:(561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2011-08-08 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-08-08 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-08-08 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2011-05-04 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-05-04 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-05-04 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2011-05-04 12:01:55 | PREVIOUS ELECTRIC REVIEW COMMENTS WERE NOT ADDRESSED. | | | | | | REQUIRES A SEPARATE ELECTRIC PERMIT AND PLAN. | | | SHOW EXISTING SERVICE LOCATION WITH SAFETY CLEARANCES, | | | POWER PLAN AND RISER. | | | SHOW EXIT SIGNS AND EMERGENCY LIGHTING. | | | SHOW GFCI PROTECTION ON APPROPRIATE OUTLETS. | | | | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2011-04-25 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-04-25 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-04-25 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2011-04-25 08:02:48 | REQUIRES A SEPARATE ELECTRIC PERMIT AND PLAN. | | | SHOW EXISTING SERVICE LOCATION WITH SAFETY CLEARANCES, | | | POWER PLAN AND RISER. | | | SHOW EXIT SIGNS AND EMERGENCY LIGHTING. | | | SHOW GFCI PROTECTION ON APPROPRIATE OUTLETS. | | | | | | | | | ROBERT LECKY | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | [email protected] | | | 561-805-6718 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2011-07-28 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-07-28 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-07-28 |
Time |
11:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2011-05-05 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-05-05 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-05-05 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2011-05-05 13:14:06 | 1258 PALM BEACH LAKES BOULEVARD | | | PERMIT #11040544 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | | | | RESTROOM DOOR SWING AND FREEZER DOOR SWING OBSTRUCTS | | | EGRESS. | | | | | | AN 8 INCH STEEL BAFFLE IS REQUIRED BETWEEN FRYER GREASE | | | AND SURFACE FLAMES OF ADJACENT COOKING EQUIPMENT. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2011-04-26 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-04-26 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-04-26 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2011-04-26 12:10:29 | 1258 PALM BEACH LAKES BOULEVARD | | | PERMIT #11040544 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | PROVIDE A LIFE SAFETY PLAN SHOWING EXIT DOORS, DOOR | | | LOCKS, TRAVEL DISTANCE TO EXITS, EXIT SIGNS, PORTABLE | | | FIRE EXTINGUISHER LOCATIONS, SEATING CONFIGURATION ETC. | | | | | | POST NUMERICAL ADDRESS ON THE BUILDING. NUMBERS SHALL | | | BE AT LEAST SIX INCHES TALL AND SHALL CONTRAST THE | | | BACKGROUND COLOR. | | | | | | IF APPLICABLE, STRUCTURES WITH LIGHT FRAME ROOF TRUSS | | | CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO | | | THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS | | | 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED | | | REFLECTIVE COLOR AND BEAR THE LETTER R DESIGNATION PER | | | FLORIDA STATUTE 633.027 AND FLORIDA ADMINISTRATIVE CODE | | | 69A-60.0081. | | | | | | ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS | | | OF NFPA 241. | | | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | GREASE COOKING EQUIPMENT SHALL BE PROVIDED WITH A TYPE | | | K EXTINGUISHER. | | | | | | SEPARATE PLANS AND PERMIT REQUIRED FOR ANY COOKING | | | EQUIPMENT FIRE SUPPRESSION SYSTEM. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-08-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-08-09 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-07-25 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2011-07-25 11:40:00 | SENT TO B15 FOR ALL TRADES REVIEW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2011-08-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-05-17 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-05-02 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-08-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-05-04 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-04-20 |
Time |
08:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2011-08-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-08-08 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-08-08 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2011-05-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-05-17 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-05-17 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2011-05-17 08:08:07 | DENIED | | | NO PLANS SUBMITTED | | | REFER TO SECTION 106.3.5 MINIMUM PLAN REVIEW CRITERIA | | | FOR BUILDINGS. | | | REFER TO SECTION 106.3.4 SITE DRAWINGS. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2011-04-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2011-04-26 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2011-04-26 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2011-04-26 07:16:08 | PLANS DENIED | | | NO MECHANICAL PLANS SUBMITTED. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2011-07-27 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-07-27 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-07-27 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2011-07-27 10:58:18 | GAS APPLICATION, DRAWING, AND PERMIT BASED ON VALUE | | | WILL BE REQUIRED FOR ANY GAS PIPE, NEW CONNECTIONS, OR | | | NEW GAS APPLIANCES TO BE INSTALLED. | | | | | | DBPR DIVISION OF HOTELS AND RESTAURANTS (H&R) LICENSES | | | WILL REQUIRE A MOP SINK THAT IS NOT IN THE FOOD | | | HANDLING AREA IF ONE IS NOT EXISTING. | | | HTTP://WWW.MYFLORIDALICENSE.COM/DBPR/HR/INDEX.HTML |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2011-05-06 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-05-06 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-05-06 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2011-05-06 13:55:01 | GAS APPLICATION, DRAWING, AND PERMIT BASED ON VALUE | | | WILL BE REQUIRED FOR ANY GAS PIPE, NEW CONNECTIONS, OR | | | NEW GAS APPLIANCES TO BE INSTALLED. | | | | | | DBPR DIVISION OF HOTELS AND RESTAURANTS (H&R) LICENSES | | | WILL REQUIRE A MOP SINK THAT IS NOT IN THE FOOD | | | HANDLING AREA IF ONE IS NOT EXISTING. | | | HTTP://WWW.MYFLORIDALICENSE.COM/DBPR/HR/INDEX.HTML |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2011-04-22 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2011-04-22 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2011-04-21 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2011-04-22 12:49:16 | FBC PLUMBING 2007 REVIEW #1 | | | DENIED: | | | | | | PLEASE REFER TO BUILDING PLAN REVIEW COMMENT #1. | | | | | | PLUMBING 403.2 SEPERATE RESTROOM FACILITIES FOR EACH | | | SEX WILL BE REQUIRED FOR MORE THAN TEN SEATS. | | | | | | A SEPERATE GAS APPLICATION, DRAWING, AND PERMIT WILL BE | | | REQUIRED IF CHANGING ANY GAS EQUIPMENT/ PIPING/ ETC. | | | | | | REVIEW BY LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | (561) 805-6692 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2011-08-09 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-08-09 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-08-09 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2011-08-09 09:17:00 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | PASSED W/PROVISO | | | SEPARATE PAVING AND LANDSCAPING PERMITS ARE REQUIRED | | | FOR THE REQUIRED RE-STRIPING AND LANDSCAPING OF THE | | | PARKING LOT. | | | THE TERMINAL AND INTERIOR ISLANDS SHOWN ON THE PLAN | | | MUST BE CURBED AND LANDSCAPED PER SEC. 94-443(C)(3). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2011-05-04 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2011-05-04 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2011-05-04 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2011-05-04 10:32:32 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | PLEASE SUBMIT A SITE PLAN SHOWING THE DUMPSTER LOCATION | | | AND ALL PARKING AND LANDSCAPING. THE PARKING | | | REQUIREMENTS CAN BE FOUND IN ARTICLE XV OF THE ZONING | | | CODE. THE REQUIREMENTS FOR LANDSCAPING ARE CONTAINED IN | | | ARTICLE XIV. | | | | | | ADDITIONAL COMMENT (5/16): | | | DURING THE WEEK OF MAY 16, 2011, CODE ENFORCEMENT NOTED | | | THAT THE CONTENT OF THE SIGN HAD BEEN CHANGED WITHOUT | | | OBTAINING A PERMIT. PERMITS ARE REQUIRED FOR ALL FACE | | | CHANGES TO SIGNAGE. PLEASE PULL THE APPROPRIATE PERMITS | | | FOR THIS SCOPE OF WORK. | | | | | | YOUR RESUBMISSION MAY GENERATE ADDITIONAL COMMENTS. |
|
|