Plan Review Details - Permit 11040450
Plan Review Stops For Permit 11040450
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-05-19 Cont ID  
Sent By shill Date 2011-05-19 Time 15:28 Rev Time 0.00
Received By shill Date 2011-05-19 Time 15:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-05-05 Cont ID  
Sent By shill Date 2011-05-05 Time 16:43 Rev Time 0.00
Received By shill Date 2011-05-05 Time 16:43 Sent To  
Notes
2011-05-05 17:00:37****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. ALTHOUGH THE INSTALLATION SCHEDULE SUBMITTED IN THE
 FIRST REVIEW WAS NOT CODE COMPLIANT, A REVISED
 INSTALLATION SCHEDULE WAS NOT RESUBMITTED. PLEASE
 COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 2. A RESPONSE NOTE WAS INCLUDED IN THE RESUBMITTAL
 WHICH STATED: "TPS=13" ACC=7.4" ANCHOR SPACING"
  
 PLEASE SEE THE ACCORDION PRODUCT APPROVAL, SHEET 10.
 THE SUBSTRATE FOR THE TOP CAN BE CONCRETE, BUT THE
 BOTTOM IS USUALLY CONCRETE BLOCK (MASONRY). THE
 CONNECTION TYPE CIRCLED ON THE CONCRETE SUBSTRATE
 ANCHOR CHART, C4, IS NOT PERMITTED FOR HOLLOW BLOCK
 SUBSTRATE, TAPCON ANCHOR. OTHER ANCHORS ARE PERMITTED
 PER SHEET 10 OF THE PRODUCT APPROVAL. INSTALLATION
 METHOD PROPOSED DOES NOT COMPLY. PLEASE REVISE THE
 INSTALLATION SCHEDULE AND RESUBMIT.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-04-21 Cont ID  
Sent By shill Date 2011-04-21 Time 11:05 Rev Time 0.00
Received By shill Date 2011-04-21 Time 11:04 Sent To  
Notes
2011-04-21 11:06:05****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. REVISE EXPOSURE CATEGORY (TO EXPOSURE C) OR PROVIDE
 ENGINEERING FOR EXPOSURE B PRESSURES. FBC1609, FBC
 R301.2.1.4. NOTE THAT THE CODE CHANGED EFFECTIVE MARCH
 1, 2009.
  
 2. THE ANCHOR CHARTS ON THE PRODUCT APPROVAL HAVE
 SPACING CIRCLED ON THE CONCRETE SUBSTRATE CHART. PRIOR
 TO RESUBMITTAL, PLEASE CONFIRM THAT ANCHOR SPACING
 COMPLIES WITH REQUIREMENTS FOR CONCRETE BLOCK SUBSTRATE
 AND INCREASED DESIGN PRESSURES. IT APPEARS THAT
 INCORRECT ANCHOR SPACING HAS BEEN SPECIFIED ON THE
 INSTALLATION SCHEDULE.
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-05-19 Cont ID  
Sent By shill Date 2011-05-19 Time 15:28 Rev Time 0.00
Received By shill Date 2011-05-10 Time 16:51 Sent To  
Notes
2011-05-10 16:52:09TO S.HILL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-05-05 Cont ID  
Sent By shill Date 2011-05-05 Time 17:00 Rev Time 0.00
Received By shill Date 2011-05-02 Time 10:02 Sent To  
Notes
2011-05-02 10:03:02SENT TO SAMANTHA'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-04-21 Cont ID  
Sent By shill Date 2011-04-21 Time 11:06 Rev Time 0.00
Received By shill Date 2011-04-19 Time 08:20 Sent To  
Notes
2011-04-19 08:21:10TO BLDG < $5K