Plan Review Details - Permit 11040368
Plan Review Stops For Permit 11040368
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-06-03 Cont ID  
Sent By jwitmer Date 2011-06-03 Time 13:59 Rev Time 0.77
Received By jwitmer Date 2011-06-03 Time 13:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-04-21 Cont ID  
Sent By jwitmer Date 2011-04-21 Time 07:58 Rev Time 0.77
Received By jwitmer Date 2011-04-20 Time 13:43 Sent To  
Notes
2011-04-21 08:10:22BUILDING PLAN REVIEW
 PERMIT: 11040368
 ADD: 7075 SANDHILL WAY EAST
 CONT: THE GRASSYROOTS CORP.E
 TEL: (561)262-3429
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLEASE REVIEW SHEET S-1 INDICATES AN "B" EXPOSURE,
 TOPOGRAPHIC MAPS INDICATE THIS TO BE A "C" ZONE. PLEASE
 SEE:
 1609.4.3 EXPOSURE C. OPEN TERRAIN WITH SCATTERED
 OBSTRUCTIONS, INCLUDING SURFACE UNDULATIONS OR OTHER
 IRREGULARITIES, HAVING HEIGHTS GENERALLY LESS THAN 30
 FEET (9144 MM) EXTENDING MORE THAN 1,500 FEET (457.2 M)
 FROM THE BUILDING SITE IN ANY QUADRANT. THIS EXPOSURE
 SHALL ALSO APPLY TO ANY BUILDING LOCATED WITHIN
 EXPOSURE B-TYPE TERRAIN WHERE THE BUILDING IS WITHIN
 100 FEET HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF
 EXPOSURE C-TYPE TERRAIN THAT EXTENDS MORE THAN 600 FEET
 (182.9 M) AND WIDTH GREATER THAN 150 FT. IN THE UPWIND
 DIRECTION.
  
 2) THE TRUSS DRAWINGS ALSO REFLECT THE "B" EXPOSURE
 PLEASE UPDATE PLANS AND PRESSURES TO REFLECT "C"
 EXPOSURE. 1609.4.3. "C" EXPOSURE DOES HAVE A MULTIPLIER
 OF 1.21.
  
 3) ROOFING PRODUCT APPROVAL SUBMITTED ENGLERT SERIES
 1300 METAL PANEL NOA 06-0906.09 PLEASE CIRCLE WHICH
 SYSTEM TO BE INSTALLED, NOTE PRESSURES WILL BE HIGHER
 WITH THE MULTIPLIER OF 1.21
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-04-18 Cont ID  
Sent By rlecky Date 2011-04-18 Time 12:26 Rev Time 0.00
Received By rlecky Date 2011-04-18 Time 12:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-06-03 Cont ID  
Sent By jwitmer Date 2011-06-03 Time 13:59 Rev Time 0.00
Received By jwitmer Date 2011-05-18 Time 16:26 Sent To  
Notes
2011-05-18 16:26:54INCOMING SENT TO ZONING BOX. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-04-28 Cont ID  
Sent By lmartine Date 2011-04-28 Time 15:09 Rev Time 0.00
Received By lmartine Date 2011-04-14 Time 14:35 Sent To  
Notes
2011-04-14 14:41:13B4

Review Stop Z ZONING
Rev No 2 Status P Date 2011-06-01 Cont ID  
Sent By lfranco Date 2011-06-01 Time 20:30 Rev Time 1.50
Received By lfranco Date 2011-05-19 Time 14:39 Sent To  
Notes
2011-06-01 20:39:55PASSED WITH PROVISO: **** THIS APPROVAL IS PART OF A
 MINOR PD AMENDMENT APPROVAL PB 993FFFFF - APPLICANT
 (KEN ROUNDTREE) INDICATED ON P&Z APPLICATION THAT THE
 ADDRESS IS 7076 SANDHILL WAY VS. PERMIT APPLICATION HAS
 7075 SANDHILL WAY (PCN 74414224060060000), APPLICANT
 INDICATED THAT THE SAME DRAWINGS WERE SUBMITTED TO THE
 CONSTRUCTION SERVICES DEPARTMENT AS WAS SUBMITTED ON
 5/9/11 MINOR AMENDMENT SUBMITTAL TO THE PLANNING AND
 ZONING (P&Z)DEPARTMENT. THE PLANS (SHEET CS-1 PACKAGED
 W/APPROVAL LETTER FROM IBIS POA STAMP) THAT WERE
 APPROVED BY THE P&Z WERE NOT SUBMITTED FOR PERMITTING.
  
 PROVISO: IDENTICAL PLANS SUBMITTED TO THE P&Z
 DEPARTMENT SHALL BE SUBMITTED THROUGH THE CONSTRUCTION
 SERVICES DEPARTMENT PRIOR TO FINAL SIGN OFF FOR
 INSPECTIONS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2011-04-21 Cont ID  
Sent By lfranco Date 2011-04-21 Time 16:55 Rev Time 0.50
Received By lfranco Date 2011-04-21 Time 16:55 Sent To  
Notes
2011-04-21 17:00:27PLANNING AND ZONING: **** FAILED ****
  
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
 SHOW LOCATION OF GENERATOR AND ENCLOSURE AND DIMENSIONS
 TO ALL PROPERTY LINES. HOW WAS THIS GENERATOR APPROVED?
  
  
 3. A MINOR AMENDMENT TO THE IBIS RESIDENTIAL PLANNED
 DEVELOPMENT ("RPD"), MASTER PLAN IS REQUIRED. AN
 APPLICATION WILL NEED TO BE FILED TO THE PLANNING AND
 ZONING DEPARTMENT AND APPROVED PRIOR TO SIGN-OFF OF THE
 BUILDING PERMIT. SHOW LOCATION ON A SURVEY/SITE PLAN.
 SHOW LANDSCAPING EXISTING/PROPOSED AROUND THE BUILDING
 ENCLOSURE.
  
  
 4. THE ADDRESS DOES NOT EXIST AND THE PARCEL CONTROL
 NUMBER (PCN) IS FOR 7076 SANDHILL WAY WHICH ARE
 DESIGNATED TO SOME WATERWAY AREAS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  