Plan Review Details - Permit 11040215
| Plan Review Stops For Permit 11040215 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-04-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2011-04-15 |
Time |
15:21 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2011-04-15 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2011-04-15 15:47:11 | | | | | | | | | | | | | | | | | | | BUILDING APPROVED WITH EXCEPTION! | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | | | | 2007/2009 FBC-B 1008.1.1 SIZE OF DOORS. THE MINIMUM | | | WIDTH OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE | | | OCCUPANT LOAD THEREOF AND SHALL PROVIDE A CLEAR WIDTH | | | OF NOT LESS THAN 32 INCHES (813 MM). CLEAR OPENINGS OF | | | DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN | | | THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN | | | 90 DEGREES |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2011-04-12 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2011-04-12 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2011-04-12 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2011-04-08 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-04-08 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-04-08 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2011-04-08 13:56:58 | 501 SOUTH FLAGLER DRIVE, SUITE #502 | | | PERMIT #11040215 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | *****APPROVED WITH PROVISIONS***** | | | | | | DEMOLITION WORK TO COMPLY WITH THE REQUIREMENTS OF NFPA | | | 241. DEBRIS SHALL BE REMOVED DAILY. | | | | | | THE NEW SIDE LIGHT GLAZING SHOWN ADJACENT TO THE SUITE | | | ENTRY DOOR APPEARS TO BE LOCATED IN A FIRE RATED | | | CORRIDOR WALL. VERIFY GLAZING IS FIRE RATED. | | | | | | NEW WALLS AND CEILING CONFIGURATION WILL AFFECT FIRE | | | SPRINKLER AND FIRE ALARM LAYOUT. SEPARATE PLANS AND | | | PERMITS ARE REQUIRED FOR THE INSTALLATION/MODIFICATION | | | OF THESE SYSTEMS. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-04-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-04-19 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-04-08 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2011-04-19 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2011-04-19 |
Time |
09:14 |
Rev Time |
0.25 |
| Received By |
aaponte |
Date |
2011-04-19 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2011-04-19 09:15:48 | INTERIOR IMPROVEMENTS ONLY FOR OFFICE SPACE. |
|
|
|