Plan Review Details - Permit 11040193
Plan Review Stops For Permit 11040193
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-06-08 Cont ID  
Sent By shill Date 2011-06-08 Time 14:46 Rev Time 0.00
Received By shill Date 2011-06-08 Time 14:46 Sent To  
Notes
2011-06-08 14:59:10****PROVISO****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 ISSUED AT CONTRACTOR'S RISK
  
 AT INSPECTION, PROVIDE A LETTER FROM ARCHITECT WHICH
 SPECIFIES WINDOW DESIGN PRESSURE REQUIREMENT TO BE LESS
 THAN +-80PSF.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-05-09 Cont ID  
Sent By shill Date 2011-05-09 Time 10:35 Rev Time 0.00
Received By shill Date 2011-05-06 Time 07:40 Sent To  
Notes
2011-05-09 10:38:07****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. (INFORMATIONAL ONLY) SEE SHEET 2 OF 13, PRODUCT
 APPROVAL. REINFORCED DOOR REQUIRED PER TABLE 1 (DOORS
 WITHOUT REINFORCEMENT DO NOT COMPLY WITH DESIGN
 PRESSURE REQUIREMENTS FOR THIS JOB). PRODUCT APPROVAL
 HAS BEEN REDLINED.
  
 2. SCOPE OF WORK INCLUDES THREE WINDOWS. ARCHITECT'S
 PLAN INCLUDES ONLY SLIDING GLASS DOORS. DESIGN
 PRESSURES TO BE SPECIFIED BY A DESIGN PROFESISONAL FBC
 1609. EITHER REVISE SCOPE OF WORK OR INCLUDE IN
 ARCHITECT'S PLAN.
  
 3. VALUE ON PERMIT APPLICATION IS TO INCLUDE LABOR AND
 MATERIALS, FBC 108.3.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-04-13 Cont ID  
Sent By shill Date 2011-04-13 Time 14:18 Rev Time 0.00
Received By shill Date 2011-04-13 Time 14:18 Sent To  
Notes
2011-04-13 14:19:41****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. ENGINEERING REQUIRED TO DETERMINE DESIGN PRESSURES
 FOR BUILDINGS OVER 60' IN HEIGHT, FBC1609.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-05-09 Cont ID  
Sent By shill Date 2011-05-09 Time 10:38 Rev Time 0.00
Received By shill Date 2011-05-04 Time 10:31 Sent To  
Notes
2011-05-04 10:32:13INCOMING SENT TO SH DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-04-13 Cont ID  
Sent By shill Date 2011-04-13 Time 14:19 Rev Time 0.00
Received By shill Date 2011-04-07 Time 12:41 Sent To  
Notes
2011-04-07 12:41:47MISC 1