Plan Review Details - Permit 11040079
Plan Review Stops For Permit 11040079
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-04-21 Cont ID  
Sent By jwitmer Date 2011-04-21 Time 14:17 Rev Time 0.00
Received By jwitmer Date 2011-04-21 Time 14:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2011-04-20 Cont ID  
Sent By jwitmer Date 2011-04-20 Time 08:26 Rev Time 3.33
Received By jwitmer Date 2011-04-13 Time 08:18 Sent To  
Notes
2011-04-13 08:33:26BUILDING PLAN REVIEW
 PERMIT: 11040079
 ADD: 1601 BELVEDERE RD
 CONT: TO BE DETERMINED
 TEL: (561)###-####
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 NOTICE TO OWNER OF A CODE VIOLATION THAT EXIST IN YOUR
 BUILDING. THE ELEVATOR LOBBY IS MISSING SEPERATION AS
 REQUIRED IN THE 2007/09 FBC-B
 SECTION 707.14.1 ELEVATOR LOBBY OR 1 OF THE 6
 EXCEPTIONS. CURRENTLY WE ARE PUTTING YOU ON NOTICE OF
 THIS VIOLATION.
  
 IN THE 2007/09 EXISTING BUILDING CODE SECTION 703.2.2
 SUPPLEMENTAL SHAFT AND FLOOR OPENING ENCLOSURE
 REQUIREMENTS. WHERE THE WORK AREA ON ANY FLOOR EXCEEDS
 50 PERCENT OF THAT FLOOR AREA, THE ENCLOSURE
 REQUIREMENTS OF SECTION 703.2 SHALL APPLY TO VERTICAL
 OPENINGS OTHER THAN STAIRWAYS THROUGHOUT THE FLOOR. THE
 WORK WHICH WILL BE COVERED UNDER THIS PERMIT DOES NOT
 MEET THIS REQUIREMENT THUS NOT REQUIRING THE ELEVATOR
 LOBBIES TO BE INSTALLED AT THIS TIME.
  
 ACTION :BUILDING PROVISO:
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) SHEET A2.2, A2.3 PLANS INDICATE ALL HOLES FEFT IN
 THE CONCRETE SLAB AFTER PIPE REMOVAL TO BE FIRE RATED-
 ANYTHING OVER 2 INCHES IN DIAMETER TO BE SEALED WITH
 CONCRETE. PLEASE REVIEW FBC-B 712.4.1 FIRE-RESISTANCE
 RATED ASSEMBLIES. PENETRATIONS OF THE FIRE-RESISTANCE
 RATED FLOOR, FLOOR/CEILING ASSEMBLY OR THE CEILING
 MEMBRANE OF A ROOF/CEILING ASSEMBLY SHALL COMPLY WITH
 SECTIONS 712.4.1.1 THROUGH 712.4.1.4. PLEASE PROVIDE
 DOCUMENTATION FOR COMPLIANCE PROVIDE CUT SHEET FOR
 PRODUCTS TO BE INSTALLED.
  
  
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-04-18 Cont ID  
Sent By rlecky Date 2011-04-18 Time 09:55 Rev Time 0.00
Received By rlecky Date 2011-04-12 Time 12:32 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-04-20 Cont ID  
Sent By mcarsill Date 2011-04-20 Time 14:10 Rev Time 0.00
Received By mcarsill Date 2011-04-20 Time 14:10 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2011-04-13 Cont ID  
Sent By mcarsill Date 2011-04-13 Time 11:14 Rev Time 0.00
Received By mcarsill Date 2011-04-13 Time 11:08 Sent To  
Notes
2011-04-13 11:14:061601 BELVEDERE ROAD
 PERMIT NUMBER 11040079
  
  
 1. ALL CONSTRUCTION, DEMOLITION, AND RENOVATION
 ACTIVITIES TO COMPLY WITH NFPA 241.
  
 2. EXIT ACCESS AND EXITS ARE TO REMAIN CLEAR AND
 UNOBSTRUCTED.
  
 3. TRASH AND DEBRIS SHALL BE REMOVED DAILY.
  
 4. SEPARATE PLANS AND PERMITS REQUIRED FOR THE FIRE
 ALARM AND FIRE SPRINKLER SYSTEM RENOVATIONS.
  
 5. ANY EXISTING SMOKE ALARMS THAT ARE TO REMAIN ARE TO
 BE CHECKED FOR PROPER OPERATION.
  
 6. ALL ELECTRICAL WORK TO COMPLY WITH NFPA 70, THE
 NATIONAL ELECTRICAL CODE.
  
 7. NO ILLUMINATED EXIT SIGNS OR EMERGENCY LIGHTS
 DISPLAYED. IT IS ASSUMED THAT SUFFICIENT QUANTITY OF
 FIXTURES EXIST AND THAT THEY ARE IN GOOD WORKING ORDER.
  
 8. SPRINKLER HEADS ARE TO BE RELOCATED AND NOT CAPPED
 ABOVE THE CEILING AS DESCRIBED IN THE DRAWINGS.
  
  
 DENIED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2011-06-28 Time   Rev Time 0.00
Received By rregueir Date 2011-04-20 Time 10:03 Sent To  
Notes
2011-04-20 10:03:54ROUND 2 UPLOADED. **DIGITAL**

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-04-20 Cont ID  
Sent By rregueir Date 2011-04-20 Time 10:03 Rev Time 0.00
Received By rregueir Date 2011-04-18 Time 16:40 Sent To  
Notes
2011-04-18 16:40:49**DIGITAL PLANS** SEE PROJECTDOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-04-18 Cont ID  
Sent By rregueir Date 2011-04-18 Time 16:40 Rev Time 0.00
Received By rregueir Date 2011-04-18 Time 16:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-04-15 Cont ID  
Sent By lwagner Date 2011-04-15 Time 11:04 Rev Time 0.00
Received By lwagner Date 2011-04-12 Time 11:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2011-06-28 Cont ID  
Sent By rregueir Date 2011-06-28 Time 10:07 Rev Time 0.00
Received By rregueir Date 2011-06-28 Time 10:07 Sent To  
Notes
***NONE***