Plan Review Details - Permit 11030778
Plan Review Stops For Permit 11030778
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-05-23 Cont ID  
Sent By rmcdouga Date 2011-05-23 Time 11:52 Rev Time 0.00
Received By rmcdouga Date 2011-05-23 Time 11:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-05-23 Cont ID  
Sent By rmcdouga Date 2011-05-23 Time 09:56 Rev Time 0.00
Received By rmcdouga Date 2011-05-23 Time 09:56 Sent To  
Notes
2011-05-23 10:14:202007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED
 BY THE OWNER/AGENT. FBC 13-103
  
 2) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 MISSILE IMPACT RATED FRENCH DOORS HAS BEEN CLOSED.
 SUBMIT CURRENT PRODUCT APPROVALS PER DCA RULE 9B-72.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-04-18 Cont ID  
Sent By rmcdouga Date 2011-04-18 Time 10:12 Rev Time 0.00
Received By rmcdouga Date 2011-04-18 Time 10:12 Sent To  
Notes
2011-04-18 10:12:342007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF A SURVEY SHOWING THE DISTANCES
 FOR THE PROPOSED ADDITION TO THE PROPERTY LINES. FBC
 R302
  
 2) SUBMIT TWO COPIES OF A DRAINAGE PLAN SHOWING
 COMPLIANCE WITH R401.3.
  
 3) SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE
 ADDITION. FBC 13-101.2.2
  
 4) SPECIFY THE ATTACHMENT OF THE WALLS TO THE FLOOR
 SYSTEM TO THE SILL PLATE TO CREATE A CONTINUOUS LOAD
 PATH AS REQUIRED BY FBC R301.1.
  
 5) SHOW COMPLIANCE WITH FBC R404.1.1.1, WHICH REQUIRES
 A REINFORCED BOND BEAM AT THE TOP OF THE FOUNDATION
 STEM WALL.
  
 6) SHOW COMPLIANCE WITH FBC R 320 FOR TERMITE
 TREATMENT.
  
 7) SHOW COMPLIANCE WITH FBC R 319.1 FOR WOOD JOISTS
 WITHIN 18" OF THE GROUND, WOOD SIDING,SHEATHING AND
 WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A
 CLEARANCE OF LESS THAN 6 INCHES FROM THE GROUND AND
 WOOD IN CONTACT WITH CONCRETE OR MASONRY.
  
 8) SHOW COMPLIANCE WITH FBC R408.1 FOR CRAWL SPACE
 VENTILATION AND R408.4 FOR CRAWL SPACE ACCESS.
  
 9) SHOW COMPLIANCE WITH FBC R806 FOR ROOF VENTILATION.
  
 10) SHOW COMPLIANCE WITH FBC R301.2.1.2 FOR PROTECTION
 OF GLAZED OPENINGS. IF STORM PANELS ARE USED. SUBMIT
 TWO COPIES OF PRODUCT APPROVALS, KEY PLANS AND AN
 INSTALLATION SCHEDULE.
  
 11) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE
 FIXED GLASS WINDOW, THE GLAZED OUTSWING FRENCH DOORS,
 THE METAL ROOFING, AND THE WOOD STRAPS AND CONNECTORS
 AS REQUIRED BY DCA RULE 9B-72.
  
 12) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED
 AND APPROVED BY THE DESIGNER OF RECORD FOR THE PROJECT.
 FBC 106.3.3 CITY AMENDMENTS.
  
 13) THE PLANS WILL BE REQUIRED TO BE REVIEWED BY PALM
 BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES ARE DUE.
  
 14) PLEASE RESPOND TO THE REVIEW COMMENTS IN WRITING
 INDICATING HOW THE ITEMS HAVE BEEN RESOLVED AND THE
 SHEETS THAT WERE REVISED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-05-23 Cont ID  
Sent By rmcdouga Date 2011-05-23 Time 10:54 Rev Time 0.00
Received By rmcdouga Date 2011-05-23 Time 10:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-04-05 Cont ID  
Sent By rlecky Date 2011-04-05 Time 09:34 Rev Time 0.00
Received By rlecky Date 2011-04-05 Time 09:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-05-23 Cont ID  
Sent By rmcdouga Date 2011-05-23 Time 09:56 Rev Time 0.00
Received By rmcdouga Date 2011-05-12 Time 09:21 Sent To  
Notes
2011-05-12 09:21:46SENT TO R1.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-05-12 Cont ID  
Sent By jgomez Date 2011-04-18 Time 09:13 Rev Time 0.00
Received By jgomez Date 2011-03-31 Time 16:41 Sent To  
Notes
2011-05-12 09:14:44LAST REVIEW WAS DONE ON 4/18/11.
2011-03-31 16:43:27R--7

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2011-05-23 Cont ID  
Sent By rmcdouga Date 2011-05-23 Time 09:55 Rev Time 0.00
Received By rmcdouga Date 2011-05-23 Time 09:55 Sent To  
Notes
2011-05-23 09:56:37MU-2011-8477

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2011-04-18 Cont ID  
Sent By rmcdouga Date 2011-04-18 Time 10:13 Rev Time 0.00
Received By rmcdouga Date 2011-04-18 Time 10:14 Sent To  
Notes
2011-04-15 11:36:12NEEDS COUNTY IMPACT FEE REVIEW.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-05-23 Cont ID  
Sent By rmcdouga Date 2011-05-23 Time 09:26 Rev Time 0.00
Received By rmcdouga Date 2011-05-23 Time 09:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-04-15 Cont ID  
Sent By rmcdouga Date 2011-04-15 Time 11:24 Rev Time 0.00
Received By rmcdouga Date 2011-04-15 Time 11:24 Sent To  
Notes
2011-04-15 11:35:352007 FBC W/2009 REVISIONS
  
 DENIED BY MECHANICAL
  
 1) SUBMIT TWO SETS OF MECHANICAL PLANS. SPECIFY ALL
 DUCT SIZES, ALL OUTLET SIZES AND CFMS PER OUTLET. SHOW
 THE LOCATIONS AND SIZES OF ALL SUPPLIES, RETURNS,
 TRANSFER DUCTS, TRANSFER GRILLS, ETC. SPECIFY THE
 LOCATIONS OF AIR HANDLERS AND CONDENSING UNITS. SPECIFY
 THE MODEL NUMBERS, AND SPECIFICATIONS FOR THE
 HEATING/COOLING EQUIPMENT ON THE PLANS.
  
 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS.
  
 3) SUBMIT TWO SETS OF HEATING AND COOLING EQUIPMENT
 SIZING CALCULATIONS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-04-15 Cont ID  
Sent By rmcdouga Date 2011-04-15 Time 11:24 Rev Time 0.00
Received By rmcdouga Date 2011-04-15 Time 11:24 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2011-05-16 Cont ID  
Sent By eschneid Date 2011-05-16 Time 10:38 Rev Time 0.45
Received By eschneid Date 2011-05-16 Time 10:38 Sent To  
Notes
2011-05-16 11:27:24PASSED

Review Stop Z ZONING
Rev No 1 Status F Date 2011-04-18 Cont ID  
Sent By eschneid Date 2011-04-18 Time 10:52 Rev Time 0.50
Received By eschneid Date 2011-04-18 Time 10:49 Sent To  
Notes
2011-04-18 11:05:32FAILED
  
 1) SUBMIT 2 COPIES OF A RECENT SURVEY, LESS THAN ONE
 YEAR OLD.
  
 2) SUBMIT 2 COPIES OF A SITE PLAN OR SURVEY WHICH SHOWS
 THE SETBACK DIMENSIONS FOR THE EXISTING HOUSE AND THE
 ADDITION TO THE EAST AND WEST SIDE PROPERTY LINES AND
 THE NORTH (REAR) PROPERTY LINE. THE SITE PLAN/SURVEY
 SHALL BE TO SCALE.
  
 3) IF THIS PROJECT INCLUDES THE INSTALLATION OF NEW
 GROUND MOUNTED A/C EQUIPMENT, THEN THE A/C EQUIPMENT
 SHALL BE SHOWN ON THE SITE PLAN/SURVEY, WITH THE
 SETBACK TO THE PROPERTY LINE.
  
 4) PROVIDE THE ROOF OVERHANG DIMENSION ON EITHER THE
 ELEVATION OR THE ROOF FRAMING PLAN. NOTE: THE ROOF MAY
 NOT OVERHANG MORE THAN 3 FEET INTO A REQUIRED SETBACK.
  
 5) THE SUBMITTAL OF THE REQUIRED INFORMATION MAY RESULT
 IN ADDITIONAL COMMENTS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.