Plan Review Details - Permit 11030727
Plan Review Stops For Permit 11030727
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2011-04-15 Cont ID  
Sent By jgomez Date 2011-04-15 Time 15:38 Rev Time 0.00
Received By jgomez Date 2011-04-15 Time 15:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By jgomez Date 2011-04-12 Time 14:13 Sent To  
Notes
2011-04-15 15:29:30TALKED TO ENGINEER TO GO OVER COMMENTS. 4/12/11.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-04-11 Cont ID  
Sent By jgomez Date 2011-04-11 Time 10:02 Rev Time 0.00
Received By jgomez Date 2011-04-11 Time 09:46 Sent To  
Notes
2011-04-11 10:32:32RESIDENTIAL (R30 REROOF SECOND CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- ENGINEER TO REVISE THE RAS 117 CALCULATIONS TO MATCH
 INFORMATION ON PAGE 17 OF NOA 09-0820.09 SUBMITTED.:
 A) NAIL SPACING OF SIDE LAP IS NOT 8". SEE NOA.
 B) NAIL SPACING OF CENTER ROWS IS NOT 8". SEE NOA.
 C) APPROVED ASSEMBLY DESIGN PRESSURES IS NOT 60 PSF.
 SEE NOA.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-03-30 Cont ID  
Sent By jgomez Date 2011-03-30 Time 13:24 Rev Time 0.00
Received By jgomez Date 2011-03-30 Time 13:24 Sent To  
Notes
2011-03-30 13:35:38RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- FLAT ROOF NOA 07-0730.03 SUBMITTED WAS SUPERSEDED BY
 MIAMI-DADE. NEED CURRENT NOA. VISIT THE MIAMI-DADE
 WEBSITE AND DOWNLOAD CURRENT NOA.
  
 2- CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY FROM
 CURRENT NOA IS GOING TO BE INSTALLED TO VERIFY
 COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301 OF
 2007 FLORIDA RESIDENTIAL CODE.
  
 3- PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT
 PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL
 LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED.
 IF NOA REQUIRES CALCULATIONS TO BE SIGNED AND SEALED,
 THEM PROVIDE SIGNED AND SEALED CALCULATIONS.
  
 ***NOTE; PERSON DOING THE RAS 117 CALCULATIONS TO TAKE
 INTO CONSIDERATION THAT ACCORDING TO SEC. R301.2.1.4.3
 THIS BUILDING IS LOCATED ON EXPOSURE "C".
  
 4- SPECIFY HOW MUCH ROOF SQUARE FOOTAGE IS GOING TO BE
 RE-ROOFED TO VERIFY COMPLIANCE WITH SEC. 108.3 CITY
 AMENDMENTS TO FBC.
 ALSO, SPECIFY THE BUILDING MEAN ROOF HEIGHT.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2011-04-15 Cont ID  
Sent By jgomez Date 2011-04-15 Time 15:28 Rev Time 0.00
Received By jgomez Date 2011-04-15 Time 15:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-04-12 Cont ID  
Sent By jgomez Date 2011-04-12 Time 14:13 Rev Time 0.00
Received By jgomez Date 2011-04-12 Time 14:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-04-11 Cont ID  
Sent By jgomez Date 2011-04-11 Time 09:46 Rev Time 0.00
Received By jgomez Date 2011-04-08 Time 16:59 Sent To  
Notes
2011-04-08 16:59:30GAVE TO JULIO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-03-30 Cont ID  
Sent By jgomez Date 2011-03-30 Time 13:24 Rev Time 0.00
Received By jgomez Date 2011-03-29 Time 12:35 Sent To  
Notes
2011-03-29 12:36:02SENT TO JULIO GOMEZ.


Account Summary | Usage Policy | Privacy Policy