Plan Review Details - Permit 11030661
| Plan Review Stops For Permit 11030661 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2011-03-25 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-03-25 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-03-25 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2011-03-25 16:07:16 | SWING GATE HAS BEEN OMITTED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2011-03-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2011-03-25 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2011-03-25 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2011-03-25 13:30:58 | 101 CLEMATIS STREET, SUITE #100 | | | PERMIT #11030661 | | | MASTER #10070589 | | | REVIEW COMMENTS ? FIRE DEPARTMENT | | | | | | *****APPROVED WITH PROVISIONS***** | | | | | | PROVIDE FIRE ALARM NOTIFICATION APPLIANCE FOR OUTDOOR | | | SEATING AREA. | | | | | | PROVIDE NONCOMBUSTIBLE FLAME CERTIFICATE FOR THE CANOPY | | | MATERIAL. | | | | | | STAIRS AND EGRESS COMPONENTS SHALL CONFORM TO THE LIFE | | | SAFETY REQUIREMENTS OF CHAPTER 7 OF NFPA 101 FLORIDA | | | 2007 EDITION. | | | | | | STAIRS SHALL BE A MINIMUM OF 36 INCHES IN WIDTH. | | | | | | PROVIDE PERMANENT WEATHERPROOF EXIT SIGN ATTACHED TO | | | SWINGING EGRESS GATE. | | | | | | HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIR. | | | HANDRAILS SHALL BE LOCATED NOT LESS THAN 34 INCHES AND | | | NOT MORE THAN 38 INCHES ABOVE THE SURFACE OF THE TREAD, | | | MEASURED VERTICALLY TO THE TOP OF THE RAIL FROM THE | | | LEADING EDGE OF THE TREAD. HANDRAIL ENDS SHALL BE | | | RETURNED TO THE WALL OR FLOOR OR SHALL TERMINATE AT | | | NEWEL POSTS. HANDRAIL CROSS SECTION SHALL HAVE A | | | DIAMETER OF NOT LESS THAN 1.25 INCHES AND NOT MORE THAN | | | 2 INCHES. | | | | | | STAIR RISERS SHALL BE BETWEEN 4 INCHES AND 7 INCHES IN | | | HEIGHT. STAIRS SHALL BE SLIP RESISTANT AND HAVE A | | | MINIMUM TREAD DEPTH OF 11 INCHES AND PREVENT THE | | | ACCUMULATION OF WATER. | | | | | | STAIRS SHALL HAVE LANDINGS AT DOOR OPENINGS. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2011-03-25 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-03-25 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-03-25 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2011-03-25 09:03:58 | IN ZONING BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2011-03-25 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2011-03-25 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2011-03-25 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
|