Plan Review Details - Permit 11030606
Plan Review Stops For Permit 11030606
Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2011-04-06 Cont ID  
Sent By mgonzale Date 2011-04-06 Time   Rev Time 0.50
Received By mgonzale Date 2011-04-06 Time   Sent To  
Notes
2011-04-06 09:13:47PASSED WITH NEW LAYOUT.
  
 MANUEL JULIAN GONZALEZ
 CSD ENGINEERING REVIEW
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-04-08 Cont ID  
Sent By shill Date 2011-04-08 Time 11:28 Rev Time 0.00
Received By shill Date 2011-03-23 Time 08:13 Sent To  
Notes
2011-03-23 08:13:42SENT TO ZONING BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2011-04-11 Cont ID  
Sent By eschneid Date 2011-04-11 Time 16:12 Rev Time 0.75
Received By eschneid Date 2011-04-11 Time 16:12 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2011-03-28 Cont ID  
Sent By eschneid Date 2011-03-28 Time 11:45 Rev Time 0.75
Received By eschneid Date 2011-03-23 Time 14:52 Sent To ENG
Notes
2011-03-28 12:13:32FAILED
  
 1) THE 1977 SURVEY PROVIDED WITH APPLICATION SHOWS
 DIFFERENCES WHEN COMPARED TO THE 2009 AERIAL. PLEASE
 PROVIDE 2 COPIES OF A RECENT SURVEY, LESS THAN ONE YEAR
 OLD. THE PROPOSED DRIVEWAY LAYOUT SHALL BE NOTED ON THE
 NEW SURVEY. THIS MAY BE HAND DRAWN, PROVIDED IT IS TO
 SCALE.
  
 2) SECTION 94-313(1)A OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR) LIMITS THE NUMBER OF
 DRIVEWAYS TO A RESIDENTIAL PROPERTY TO ONE (1).
 DRIVEWAYS MAY BE NO GREATER THAN 20 FEET. A CIRCULAR
 DRIVE IS CONSIDERED AS ONE DRIVEWAY, PROVIDED THAT
 NEITHER THE ENTRY OR THE EXIT BE WIDER THAN 10 FEET.
 THE PROPOSED DRIVEWAY LAYOUT SHOWS THREE DRIVEWAYS -
 THE REBUILT EXISTING DRIVEWAY PLUS TWO (2) DRIVEWAYS
 EACH AT 11 FEET WIDE. THE PROPOSED LAYOUT NEEDS TO BE
 REVISED TO COMPLY WITH CODE.
  
 3) PLEASE DESCRIBE THE CONSTRUCTION OF THE PAVER DRIVE
 AND SIDEWALK.
  
 A. WHAT TYPE OF PAVERS?
  
 B. WHAT IS THE SURFACE THAT THE PAVERS WILL BE PLACED
 ON TOP OF?
  
 C. WILL THE PAVERS BE SEALED OR UNSEALED?
  
 4) PURSUANT TO SECTION 94-482 OF THE ZLDR: REQUIRED
 OFF-STREET PARKING SPACES FOR LESS THAN FOUR
 RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE
 PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED
 PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE
 LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT
 YARD AREA MUST BE LANDSCAPED. PLEASE INDICATE THE
 SQUARE FOOTAGE OF ALL PAVING/PAVERS PROPOSED WITHIN THE
 FRONT YARD (FROM THE FRONT PROPERTY LINE TO THE FRONT
 BUILDING FACADE) ON THE PLANS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  